Days Inn Windsor
6311 ROSTAD CIR, Windsor, WI 53598 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 73708-81979
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 28 | 0 |
| 2024 | 1 | 8 | 0 |
| 2023 | 1 | 5 | 0 |
| 2021 | 2 | 8 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 3 | 0 | 0 |
| 2015 | 2 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 17, 2026 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER - Not Corrected
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
09a - FLOW METER (P - Not Corrected
The flow meter is not functional.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
16a - pH (P) - Not Corrected
The pH is 7.9
Correction: Maintain the pH between 7.2 and 7.8.
Code ATCP 76.14(5)(c)
-
Not serious
Action taken:
16b - CYANURIC ACID - Not Corrected
The cyanuric acid concentration is 100 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower. Stabilizer should not be used in an indoor pool.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
16c - ALKALINITY (Pf) - Not Corrected
The total alkalinity is 200 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf) - Not Corrected
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected
Some testing reagents are expired.
Correction: Store reagents properly, in original containers, replace when expired.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE - Not Corrected
The test kit reagents are expired.
Correction: Replace expired reagents.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS - Not Corrected
Alkalinity and combined chlorine are not being recorded.
Correction: Perform water testing in accordance with ATCP 76.18(1). Alkalinity must be tested at least 1x/week. Combined chlorine must be tested at least 2x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf) - Not Corrected
The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(1). Combined chlorine must be tested at least 2x/week and alkalinity tested at least 1x/week.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken: Emergency phone provided d
Corrected on site
26n - TELEPHONE - LOCATION - Not Corrected
There is no emergency telephone.
Correction: Provide a functional emergency telephone in an accessible location in the enclosure.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26p - FIRST AID KIT - AVAILABLE - Not Corrected
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
29d - DECK MAINTENANCE AND CLEANING (Pf) - Not Corrected
The deck is in poor repair and chipping in various areas.
Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
31a - WALLS, CEILING AND FLOORS - Not Corrected
Pool deck is pitted in many areas.
Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition. Deck needs refinishing.
Code ATCP 76.33(1)(c)
-
Not serious
Action taken: Pool was voluntarily close
Corrected on site
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED - Not Corrected
The equalizer cover in the pool is coming away from the wall creating an entrapment hazard.
Correction: Properly locate, install, maintain and repair equipment. The pool must be closed and remain closed until repaired.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
32b - VENTILATION - Not Corrected
The pool enclosure surfaces are showing signs of excessive condensation and air quality problems in indoor enclosures.
Correction: Repair the ventilation system to prevent condensation and air quality problems.
Code ATCP 76.33(4)(b)
-
Not serious
Other
Corrected on site
34e - VGBA COVERS - Not Corrected
Equalizer cover missing in pool.
Correction: Replace equalizer cover.
Code ATCP 76.11(2)(b)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected
No documentation is available on site for VGBA qualizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Mar 23, 2026 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
16a - pH (P)
The pH is 7.9
Correction: Maintain the pH between 7.2 and 7.8.
Code ATCP 76.14(5)(c)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 200 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE (Pf)
Some testing reagents are expired.
Correction: Store reagents properly, in original containers, replace when expired.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(1). Combined chlorine must be tested at least 2x/week and alkalinity tested at least 1x/week.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
29d - DECK MAINTENANCE AND CLEANING (Pf)
The deck is in poor repair and chipping in various areas.
Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken: Pool was voluntarily close
Corrected on site
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
The equalizer cover in the pool is coming away from the wall creating an entrapment hazard.
Correction: Properly locate, install, maintain and repair equipment. The pool must be closed and remain closed until repaired.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
32b - VENTILATION
The pool enclosure surfaces are showing signs of excessive condensation and air quality problems in indoor enclosures.
Correction: Repair the ventilation system to prevent condensation and air quality problems.
Code ATCP 76.33(4)(b)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA qualizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Nov 20, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
16b - CYANURIC ACID
The cyanuric acid concentration is 100 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower. Stabilizer should not be used in an indoor pool.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE
The test kit reagents are expired.
Correction: Replace expired reagents.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
Alkalinity and combined chlorine are not being recorded.
Correction: Perform water testing in accordance with ATCP 76.18(1). Alkalinity must be tested at least 1x/week. Combined chlorine must be tested at least 2x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken: Emergency phone provided d
Corrected on site
26n - TELEPHONE - LOCATION
There is no emergency telephone.
Correction: Provide a functional emergency telephone in an accessible location in the enclosure.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26p - FIRST AID KIT - AVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
31a - WALLS, CEILING AND FLOORS
Pool deck is pitted in many areas.
Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition. Deck needs refinishing.
Code ATCP 76.33(1)(c)
-
Not serious
Other
Corrected on site
34e - VGBA COVERS
Equalizer cover missing in pool.
Correction: Replace equalizer cover.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Oct 24, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 525 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The alkalinity and combined chlorine are not being tested and recorded. Pool has no recorded pH and disinfectant readings for Oct 21, 22, 23 and morning of 24.
Correction: Perform water testing in accordance with ATCP 76.18(1). Alkalinity must be tested at least 1x/week and combined chlorine must be tested at least 2x/week. Disinfectant and pH must be tested every day.
Code ATCP 76.18(1)
-
Not serious
Action taken:
31a - WALLS, CEILING AND FLOORS
Pool deck has areas that need resurfacing.
Correction: Maintain the walls, ceilings, and floors in good repair and a clean, sanitary condition.
Code ATCP 76.33(1)(c)
-
Not serious
Other
Repeat
34e - VGBA COVERS
No documentation is available on site for VGBA equalizer cover replacement. The main drain covers for the pool are recorded on the VGBA log with a replacement date of 12/13/2017 but there is no record or invoices/receipts for the equalizer cover. This has been noted on previous inspections as well.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Oct 6, 2021 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE
The test kit reagents are expired.
Correction: Obtain/purchase new reagents for daily water testing. DPD reagent #1 and #2 and pH indicator are expired. Did not check all reagents; insure reagents for alkalinity testing are unexpired.
Code ATCP 76.17(2)
-
Not serious
Action taken:
21c - DIRECTION OF FLOW
The water treatment system piping is not adequately marked with permanent labels indicating direction of flow.
Correction: Mark the water treatment system piping to indicate direction of flow.
Code ATCP 76.11(5m)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING
The signage 'No Lifeguard on Duty' does not meet the requirements of ATCP 76. The lettering is too small.
Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.22(1)(c); ATCP 76.23(2)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Numerous items are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit: 4x4 gauze pads 8x10 gauze pads Adhesive bandages Triangular bandages Scissors Gauze roller bandage Tweezers Adhesive tape Eye wash Elastic bandage Disposable surgical gloves Resuscitation pocket face mask Instant cold packs
Code ATCP 76.27(1)
-
Not serious
1. Do not enter the pool if you have a c
27e - SIGNAGE - POOL RULES
The following rules are missing from the posting: Diaper changing on the pool deck is prohibited. Glass and shatterable items are prohibited in the pool area.
Correction: Provide a sign in compliance with ATCP 76.29(1)(b). ***Letting must be in at least 1 inch tall lettering***
Code ATCP 76.29(1)(b)
-
Not serious
Action taken:
29a - FACILITY CLEANING
Pool deck is in need of cleaning.
Correction: Keep the facility in a clean condition pursuant to ATCP 76.33(1)(a).
Code ATCP 76.33(1)(a)
-
Not serious
Other
34e - VGBA COVERS
Incomplete documentation for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. VGBA Drain and Equalizer Cover Replacement Log is on clipboard with pool testing results. The log record only documents 2 pool drain covers and 2 whirlpool drain covers. There is no documentation for the equalizer covers on the pool walls. Additionally, for all drain covers, an invoice or receipt is needed to verify the accuracy of the information on the record log. This has been noted during a prior inspection, in June 2021.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 8, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Sep 21, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Sep 7, 2017 Re-Inspection · No Reinspection Required
No violations cited.
-
Aug 16, 2017 Routine Inspection · Reinspection Required
No violations cited.
-
Jan 19, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Nov 12, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Feb 10, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Feb 25, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Nov 5, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.