Days Inn Windsor

6311 ROSTAD CIR, Windsor, WI 53598 · Dane County

49cited violations
0serious tier
14inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
73708-81979
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262280
2024180
2023150
2021280
2018100
2017300
2015200
2014100
2012100

Inspections

  1. Jul 17, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER - Not Corrected

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      09a - FLOW METER (P - Not Corrected

      The flow meter is not functional.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16a - pH (P) - Not Corrected

      The pH is 7.9

      Correction: Maintain the pH between 7.2 and 7.8.

      Code ATCP 76.14(5)(c)

    • Not serious Action taken:

      16b - CYANURIC ACID - Not Corrected

      The cyanuric acid concentration is 100 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower. Stabilizer should not be used in an indoor pool.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      16c - ALKALINITY (Pf) - Not Corrected

      The total alkalinity is 200 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected

      Some testing reagents are expired.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE - Not Corrected

      The test kit reagents are expired.

      Correction: Replace expired reagents.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS - Not Corrected

      Alkalinity and combined chlorine are not being recorded.

      Correction: Perform water testing in accordance with ATCP 76.18(1). Alkalinity must be tested at least 1x/week. Combined chlorine must be tested at least 2x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf) - Not Corrected

      The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(1). Combined chlorine must be tested at least 2x/week and alkalinity tested at least 1x/week.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken: Emergency phone provided d Corrected on site

      26n - TELEPHONE - LOCATION - Not Corrected

      There is no emergency telephone.

      Correction: Provide a functional emergency telephone in an accessible location in the enclosure.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26p - FIRST AID KIT - AVAILABLE - Not Corrected

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf) - Not Corrected

      The deck is in poor repair and chipping in various areas.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS - Not Corrected

      Pool deck is pitted in many areas.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition. Deck needs refinishing.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken: Pool was voluntarily close Corrected on site

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED - Not Corrected

      The equalizer cover in the pool is coming away from the wall creating an entrapment hazard.

      Correction: Properly locate, install, maintain and repair equipment. The pool must be closed and remain closed until repaired.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      32b - VENTILATION - Not Corrected

      The pool enclosure surfaces are showing signs of excessive condensation and air quality problems in indoor enclosures.

      Correction: Repair the ventilation system to prevent condensation and air quality problems.

      Code ATCP 76.33(4)(b)

    • Not serious Other Corrected on site

      34e - VGBA COVERS - Not Corrected

      Equalizer cover missing in pool.

      Correction: Replace equalizer cover.

      Code ATCP 76.11(2)(b)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site for VGBA qualizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Mar 23, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16a - pH (P)

      The pH is 7.9

      Correction: Maintain the pH between 7.2 and 7.8.

      Code ATCP 76.14(5)(c)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 200 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      Some testing reagents are expired.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(1). Combined chlorine must be tested at least 2x/week and alkalinity tested at least 1x/week.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      The deck is in poor repair and chipping in various areas.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

    • Not serious Action taken: Pool was voluntarily close Corrected on site

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      The equalizer cover in the pool is coming away from the wall creating an entrapment hazard.

      Correction: Properly locate, install, maintain and repair equipment. The pool must be closed and remain closed until repaired.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      32b - VENTILATION

      The pool enclosure surfaces are showing signs of excessive condensation and air quality problems in indoor enclosures.

      Correction: Repair the ventilation system to prevent condensation and air quality problems.

      Code ATCP 76.33(4)(b)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA qualizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Nov 20, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 100 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower. Stabilizer should not be used in an indoor pool.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      The test kit reagents are expired.

      Correction: Replace expired reagents.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      Alkalinity and combined chlorine are not being recorded.

      Correction: Perform water testing in accordance with ATCP 76.18(1). Alkalinity must be tested at least 1x/week. Combined chlorine must be tested at least 2x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken: Emergency phone provided d Corrected on site

      26n - TELEPHONE - LOCATION

      There is no emergency telephone.

      Correction: Provide a functional emergency telephone in an accessible location in the enclosure.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26p - FIRST AID KIT - AVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS

      Pool deck is pitted in many areas.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition. Deck needs refinishing.

      Code ATCP 76.33(1)(c)

    • Not serious Other Corrected on site

      34e - VGBA COVERS

      Equalizer cover missing in pool.

      Correction: Replace equalizer cover.

      Code ATCP 76.11(2)(b)

  4. Oct 24, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 525 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The alkalinity and combined chlorine are not being tested and recorded. Pool has no recorded pH and disinfectant readings for Oct 21, 22, 23 and morning of 24.

      Correction: Perform water testing in accordance with ATCP 76.18(1). Alkalinity must be tested at least 1x/week and combined chlorine must be tested at least 2x/week. Disinfectant and pH must be tested every day.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS

      Pool deck has areas that need resurfacing.

      Correction: Maintain the walls, ceilings, and floors in good repair and a clean, sanitary condition.

      Code ATCP 76.33(1)(c)

    • Not serious Other Repeat

      34e - VGBA COVERS

      No documentation is available on site for VGBA equalizer cover replacement. The main drain covers for the pool are recorded on the VGBA log with a replacement date of 12/13/2017 but there is no record or invoices/receipts for the equalizer cover. This has been noted on previous inspections as well.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Oct 6, 2021 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      The test kit reagents are expired.

      Correction: Obtain/purchase new reagents for daily water testing. DPD reagent #1 and #2 and pH indicator are expired. Did not check all reagents; insure reagents for alkalinity testing are unexpired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      21c - DIRECTION OF FLOW

      The water treatment system piping is not adequately marked with permanent labels indicating direction of flow.

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      The signage 'No Lifeguard on Duty' does not meet the requirements of ATCP 76. The lettering is too small.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      Numerous items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit: 4x4 gauze pads 8x10 gauze pads Adhesive bandages Triangular bandages Scissors Gauze roller bandage Tweezers Adhesive tape Eye wash Elastic bandage Disposable surgical gloves Resuscitation pocket face mask Instant cold packs

      Code ATCP 76.27(1)

    • Not serious 1. Do not enter the pool if you have a c

      27e - SIGNAGE - POOL RULES

      The following rules are missing from the posting: Diaper changing on the pool deck is prohibited. Glass and shatterable items are prohibited in the pool area.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b). ***Letting must be in at least 1 inch tall lettering***

      Code ATCP 76.29(1)(b)

    • Not serious Action taken:

      29a - FACILITY CLEANING

      Pool deck is in need of cleaning.

      Correction: Keep the facility in a clean condition pursuant to ATCP 76.33(1)(a).

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34e - VGBA COVERS

      Incomplete documentation for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. VGBA Drain and Equalizer Cover Replacement Log is on clipboard with pool testing results. The log record only documents 2 pool drain covers and 2 whirlpool drain covers. There is no documentation for the equalizer covers on the pool walls. Additionally, for all drain covers, an invoice or receipt is needed to verify the accuracy of the information on the record log. This has been noted during a prior inspection, in June 2021.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Jun 8, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Sep 21, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Sep 7, 2017 Re-Inspection · No Reinspection Required

    No violations cited.

  9. Aug 16, 2017 Routine Inspection · Reinspection Required

    No violations cited.

  10. Jan 19, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Nov 12, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Feb 10, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Feb 25, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Nov 5, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.