Fairfield Inn & Suites Madison - Verona
613 W VERONA AVE, Verona, WI 53593 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2015-00347
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 9 | 0 |
| 2024 | 2 | 14 | 0 |
| 2022 | 2 | 10 | 0 |
| 2019 | 2 | 0 | 0 |
| 2017 | 2 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
Inspections
-
Feb 11, 2026 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf) - Not Corrected
Chemical storage room does not have a list of emergency numbers posted or available.
Correction: Mark door to indicate entry is for authorized personnel only. Provide a list if emergency telephone numbers in the chemical storage room or have readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken:
-
Feb 3, 2026 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
04a - SKIMMER FUNCTION (Pf)
The skimmer float valve located beneath the skimmer basket is missing the adjustable flow piece.
Correction: Repair or replace the skimmer float valve.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemical storage room door is not marked to indicate authorized personnel only and a list of emergency numbers was not present in the room.
Correction: Mark door to indicate entry is for authorized personnel only. Provide a list if emergency telephone numbers in the chemical storage room or have readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken: Operator agreed to immedia
Corrected on site
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator is knowledgeable and testing interlock weekly, but is not documenting it.
Correction: Maintain documentation of interlock testing.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN
Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.
Correction: Add statement in minimum one inch tall letters indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b).
Code ATCP 76.29(1)(c)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Other
Corrected on site
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for the VGBA equalizer cover showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Oct 16, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Operator separated chemica
Corrected on site
11b - CHEMICAL - STORAGE
Liquid chlorine and acid are stored too close together in chemical room.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine and alkalinity is not in compliance with ATCP 76.18(1). Operator is not writing numerical values and is using check marks in their daily testing log.
Correction: Perform water testing in accordance with ATCP 76.18(1). Test alkalinity at least once a week and combined chlorine at least twice a week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers are not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Multiple items are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit; Gauze pads, adhesive bandages, gauze roller bandages, adhesive tape, eye wash, elastic bandage, disposable surgical gloves, resuscitation pocket face mask and instant cold packs.
Code ATCP 76.27(1)
-
Not serious
Action taken: DATCP form provided.
28b - FECAL CONTAMINATION DOCUMENTATION
Operator does not have any required documentation forms available in case of fecal incident.
Correction: Document each fecal accident.
Code ATCP 76.31(2)
-
Not serious
Action taken: Operator separated chemica
Corrected on site
-
Feb 22, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
05a - SKIMMER/MAIN DRAIN RATIO
The skimmer to main drain flow ratio is not set correctly. Skimmer valve is less than 80%.
Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) for the skimmer is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE
Chlorine and acid are stored together without separation.
Correction: Store chemicals in accordance with ATCP 76.12(2). Store acid away from chlorine.
Code ATCP 76.12(2)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2/week and alkalinity 1/week.
Code ATCP 76.18(3)
-
Not serious
Action taken:
26g - PATRON LOAD - TOO HIGH
The maximum patron load posted in the facility is too high. Patron load posted is 20 but should be 17.
Correction: Post the maximum patron load.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken: Instructions provided duri
Corrected on site
26m - TELEPHONE - NOT WORKING
The emergency telephone rings to front desk. Front desk attendant did not know procedure for calling 911 for emergencies.
Correction: Provide instructions to all front desk attendants on emergency pool procedures. Front desk must be manned and pick phone up for all hours pool is open.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Any of the following conditions or situa
Corrected on site
28a - CLOSING CRITERIA
The pool was not closed under the following condition: Non-operational disinfectant feeder.
Correction: Ensure that the closing criteria are adhered to under the listed below.
Code ATCP 76.30
-
Not serious
Action taken:
-
Nov 29, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
16d - COMBINED CHLORINE
The combined chlorine is 1ppm.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency phone number is not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26p - FIRST AID KIT - AVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Feb 2, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Stored all chemical in pum
11b - CHEMICAL - STORAGE
Chemicals are improperly stored in accordance with ATCP 76.12(2). Liquid chlorine stored in pool room.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken:
16d - COMBINED CHLORINE
The combined chlorine is 1 ppm.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: Stored all chemical in pum
-
Mar 19, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Mar 19, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Oct 30, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Mar 6, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Dec 29, 2015 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.