High Point Woods Apartments
1 HIGH POINT WOODS DR, Madison, WI 53719 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 61537-58780
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 41 | 0 |
| 2025 | 1 | 13 | 0 |
| 2024 | 2 | 8 | 0 |
| 2022 | 2 | 11 | 0 |
| 2021 | 2 | 0 | 0 |
| 2019 | 2 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 2 | 0 | 0 |
| 2015 | 2 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 3 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Sep 10, 2026 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Operator adjusted valves.
05a - SKIMMER/MAIN DRAIN RATIO (Pf) - Not Corrected
The skimmer to main drain flow ratio is not set correctly. It was corrected onsite during the routine inspection, but the valves were returned to their original incorrect positions.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf) - Not Corrected
Safety data sheets are not available for all chemicals used in the facility. The only safety data sheet available is for sodium bisulfate.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected
Documentation of monthly interlock system testing does not include results (pass/fail).
Correction: Document monthly interlock system test results as pass/fail.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf) - Not Corrected
1) The water testing frequency for combined chlorine, alkalinity, and cyanuric acid does not meet code requirements. 2) The water test frequency for free chlorine does not meet code requirements on 9/1-9/4 and 8/30-8/31. 3) The pool water was not tested on 8/29.
Correction: Chlorine shall be tested in increments of 0.2 ppm. Perform water testing in accordance with ATCP 76.18(1). The pool water is required to be tested even on days the pool is closed.
Code ATCP 76.17(1): ATCP 76.18(1)
-
Not serious
Action taken:
21d - READABLE CHART - Not Corrected
There is no readable chart that corresponds to the valves and piping.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken: Manager states employee is
23b - NO CPO (Pf) - Not Corrected
The facility is not staffed with a current certified pool operator when required. A certified pool operator is required when active managerial control over the pool operation is lacking by having 2 or more reinspections in a 3-year period.
Correction: Acquire or train a certified pool operator for the facility.
Code ATCP 76.20(2)(a)
-
Not serious
Action taken: Operator adjusted valves.
-
Aug 26, 2026 Re-Inspection · Reinspection Required
-
Not serious
Action taken: Operator adjusted valves.
05a - SKIMMER/MAIN DRAIN RATIO (Pf) - Not Corrected
The skimmer to main drain flow ratio is not set correctly. It was corrected onsite during the routine inspection, but the valves were returned to their original incorrect positions.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
05a - SKIMMER/MAIN DRAIN RATIO (Pf) - Not Corrected
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
08a - RECIRCULATION RATE - SWIM/COMBO (Pf) - Not Corrected
The swimming pool or combination pool has a maximum turnover rate of 10.045 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(c)
-
Not serious
Action taken:
09a - FLOW METER (P - Not Corrected
The flow meter is not functional or installed properly.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
10a - FILTER DATA PLATE - Not Corrected
The manufacturer’s data plate on the filter is not easily visible and had worn away.
Correction: Post manufacturer’s information on the filter in a visible location.
Code ATCP 76.11(6)(a)
-
Not serious
Action taken:
10a - FILTER DATA PLATE - Not Corrected
The manufacturer’s data plate on the filter is missing.
Correction: Post manufacturer’s information on the filter in a visible location.
Code ATCP 76.11(6)(a)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf) - Not Corrected
A list of emergency telephone numbers is not present in the chemical storage area.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf) - Not Corrected
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected
Documentation of monthly interlock system testing does not include results (pass/fail).
Correction: Document monthly interlock system test results as pass/fail.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
16b - CYANURIC ACID (Pf) - Not Corrected
The cyanuric acid concentration is >100 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken:
16c - ALKALINITY (Pf) - Not Corrected
The total alkalinity is 280ppm
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected
Water test reagents are expired.
Correction: Store reagents properly, in original containers, replace when expired.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf) - Not Corrected
1) Free chlorine is tested in increments of 0.5 ppm. 2) The water testing frequency for free chlorine, combined chlorine, pH, alkalinity, and cyanuric acid is not in compliance with ATCP 76.18(1).
Correction: Chlorine shall be tested in increments of 0.2 ppm. Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.17(1): ATCP 76.18(1)
-
Not serious
Action taken:
21c - DIRECTION OF FLOW - Not Corrected
Not all of the water treatment system piping is marked with a permanent label indicating direction of flow.
Correction: Mark the water treatment system piping to indicate direction of flow.
Code ATCP 76.11(5m)
-
Not serious
Action taken:
21d - READABLE CHART - Not Corrected
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
23b - NO CPO (Pf) - Not Corrected
The facility is not staffed with a current certified pool operator when required. A certified pool operator is required when active managerial control over the pool operation is lacking by having 2 or more reinspections in a 3-year period.
Correction: Acquire or train a certified pool operator for the facility.
Code ATCP 76.20(2)(a)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected
Elastic bandage is missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken:
30e - SOAP (Pf) - Not Corrected
The soap dispenser in the women's shower is empty. There is no permanently installed soap dispenser in the men's shower.
Correction: Install operable soap dispensers in the showers. Keep soap dispensers stocked at all times.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED - Not Corrected
Lines going into heater are leaking and plug to old chemical line is leaking.
Correction: Maintain and repair all leaks.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected
The pump curve is not available.
Correction: Provide pump curve. Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken: Operator adjusted valves.
-
Jul 20, 2026 Routine Inspection · Reinspection Required
-
Not serious
Action taken: Operator adjusted valves.
Corrected on site
05a - SKIMMER/MAIN DRAIN RATIO (Pf)
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional or installed properly.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
10a - FILTER DATA PLATE
The manufacturer’s data plate on the filter is not easily visible and had worn away.
Correction: Post manufacturer’s information on the filter in a visible location.
Code ATCP 76.11(6)(a)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
A list of emergency telephone numbers is not present in the chemical storage area.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf)
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Documentation of monthly interlock system testing does not include results (pass/fail).
Correction: Document monthly interlock system test results as pass/fail.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
16b - CYANURIC ACID (Pf)
The cyanuric acid concentration is >100 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE (Pf)
Some chlorine and alkalinity water test reagents are expired.
Correction: Store reagents properly, in original containers, replace when expired.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
1) Free chlorine is tested in increments of 0.5 ppm. 2) The water testing frequency for free chlorine, combined chlorine, pH, alkalinity, and cyanuric acid is not in compliance with ATCP 76.18(1).
Correction: Chlorine shall be tested in increments of 0.2 ppm. Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.17(1): ATCP 76.18(1)
-
Not serious
Action taken:
21c - DIRECTION OF FLOW
Not all of the water treatment system piping is marked with a permanent label indicating direction of flow.
Correction: Mark the water treatment system piping to indicate direction of flow.
Code ATCP 76.11(5m)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
23b - NO CPO (Pf)
The facility is not staffed with a current certified pool operator when required. A certified pool operator is required when active managerial control over the pool operation is lacking by having 2 or more reinspections in a 3-year period.
Correction: Acquire or train a certified pool operator for the facility.
Code ATCP 76.20(2)(a)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf)
Adhesive tape, eye wash, elastic bandage are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken:
30e - SOAP (Pf)
The soap dispenser in the women's shower is empty. there is no permanently installed soap dispenser in the men's shower.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
The pump curve is not available.
Correction: Provide pump curve. Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken: Operator adjusted valves.
Corrected on site
-
Jun 5, 2025 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
02a - LICENSE POSTED PUBLIC VIEW
The license is not posted in a place visible to the public.
Correction: Post the license in public view.
Code ATCP 76.05(7)
-
Not serious
Action taken:
05a - SKIMMER/MAIN DRAIN RATIO (Pf)
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken: Operator cleaned baskets
Corrected on site
06b - STRAINER BASKET CLEANED
Strainer baskets or screens are not cleaned regularly.
Correction: Clean strainer baskets and screens daily to prevent the accumulation of debris.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
08a - RECIRCULATION RATE - SWIM/COMBO (Pf)
The swimming pool or combination pool has a maximum turnover rate of 10.045 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(c)
-
Not serious
Action taken:
10a - FILTER DATA PLATE
The manufacturer’s data plate on the filter is missing.
Correction: Post manufacturer’s information on the filter in a visible location.
Code ATCP 76.11(6)(a)
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf)
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility including acid, chlorine, and all taylor test kit reagents.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
Corrected on site
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demostrate knowledge or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 280ppm
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken: Operator posted sign while
Corrected on site
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken: Operator placed crook end
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)
Shepards crook was too short to reach center of pool.
Correction: Mount properly sized [equipment], position in a consipicuous place that is readily accessible, and maintain in good repair.
Code ATCP 76.26(1)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Lines going into heater are leaking and plug to old chemical line is leaking.
Correction: Maintain and repair all leaks.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken: Operator placed alarm in p
Corrected on site
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken:
-
Jun 14, 2024 Re-Inspection · No Reinspection Required
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Other
-
Jun 13, 2024 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
05b - WATER LEVEL
The pool water level is not adequate for continuous effective surface skimming.
Correction: Adjust the water level until the skimming of the water surface is adequate.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
06b - STRAINER BASKET CLEANED
Strainer baskets or screens are not cleaned regularly.
Correction: Clean strainer baskets and screens daily to prevent the accumulation of debris.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Several items are missing from the first aid kit.
Correction: The first aid kit shall contain the following items: (a) 4 x 4 Gauze pads, (b) 8 x 10 Gauze pads, (c) Adhesive bandages, (d) Triangular bandages, (e) Scissors, (f) Gauze roller bandage, (g) Tweezers, (h) Adhesive tape, (i) Eye wash, (j) Elastic bandage, (k) Disposable surgical gloves, (l) Resuscitation pocket face mask, and (m) Instant cold packs.
Code ATCP 76.27(1)
-
Not serious
Action taken:
30e - SOAP
The soap dispenser in the shower has not been permanently installed.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 15, 2022 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
04b - SKIMMERS/GUTTERS CLEANED - Not Corrected
Skimmers and skimmer weirs are not clean. Leaves in baskets.
Correction: Maintain in a clean condition.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
Repeat
16b - CYANURIC ACID - Not Corrected
The cyanuric acid concentration is 70ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
-
Jul 6, 2022 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
04b - SKIMMERS/GUTTERS CLEANED
Skimmers and skimmer weirs are not clean. Leaves in baskets.
Correction: Maintain in a clean condition.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
Repeat
04c - SKIMMER BASKET/WEIR
A weir is missing.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
Repeat
09a - FLOW METER
The flow meter is not properly functional. Debris in flow meter does not allow gauge to properly float.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
Repeat
16b - CYANURIC ACID
The cyanuric acid concentration is 70ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
Repeat
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine, cyanuric acid and alkalinity is not in compliance with ATCP 76.18(1). Pool was open for use with the public but water had not yet been tested for pH or disinfectant residue.
Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine 2/week, cyanuric acid 1/week and alkalinity 1/week. Test water for pH and disinfectant residual before the pool is open to the public or before the pool is in use and at least on other time during the day's peak patron load.
Code ATCP 76.18(1)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken:
33c - LANDSCAPING - NOT MAINTAINED
The grounds are not being maintained to prevent debris from entering the water. Tree branches are overhanging the deck area.
Correction: Maintain the grounds.
Code ATCP 76.34(6)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 1, 2021 Re-Inspection · No Reinspection Required
No violations cited.
-
Jun 22, 2021 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 19, 2019 Re-Inspection · No Reinspection Required
No violations cited.
-
Jun 4, 2019 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 5, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 16, 2017 Re-Inspection · No Reinspection Required
No violations cited.
-
Jun 6, 2017 Routine Inspection · Reinspection Required
No violations cited.
-
Aug 12, 2015 Reinspection · Reinspection Required
No violations cited.
-
Jul 30, 2015 Routine Inspection · Reinspection Required
No violations cited.
-
Jul 30, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 7, 2013 Reinspection · No Reinspection Required
No violations cited.
-
Jul 29, 2013 Reinspection · Reinspection Required
No violations cited.
-
Jul 29, 2013 Routine Inspection · Reinspection Required
No violations cited.
-
Aug 22, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.