Holiday Inn Express & Suites
515 W VERONA AVE, Verona, WI 53593 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 74083-82580
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 0 |
| 2024 | 3 | 23 | 0 |
| 2022 | 2 | 8 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2017 | 2 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 2 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Feb 23, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: New valves are onsite awai
05a - SKIMMER/MAIN DRAIN RATIO (Pf)
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional. The float appears to be stuck.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemical storage room door is not marked to indicate authorized personnel only and a list of emergency numbers was not present in the room.
Correction: Mark door to indicate entry is for authorized personnel only. Provide a list if emergency telephone numbers in the chemical storage room or have readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
26s - BLANKETS MISSING (Pf)
2 conventional or emergency blankets are not available in the pool area.
Correction: Provide 2 conventional or emergency blankets in the pool area.
Code ATCP 76.27(1)(3)
-
Not serious
Action taken:
33a - HAZARDOUS MATERIAL (P)
The timer for the whirlpool jets have settings of 5, 10, 15, and 30 minutes.
Correction: A manually controlled, 15-minute maximum, agitation system timer shall be provided within the pool enclosure.
Code ATCP 76.34(1)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
The pump curve is not available.
Correction: For a pool constructed before the effective date of this rule , the operator shall provide at a minimum, the pump curve and the drain cover specification.
Code ATCP 76.38
-
Not serious
Action taken: New valves are onsite awai
-
Nov 22, 2024 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Operator unsure if valves
05a - SKIMMER/MAIN DRAIN RATIO - Not Corrected
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken: Operator printed off pool
11e - SDS AVAILABILITY - Not Corrected
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Operator tested 4 times pe
14e - WATER POTENTIAL ORP - Not Corrected
The water potential was 113 mV at the time of the reinspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: Operator contacted pool co
31b - EQUIPMENT NOT MAINTAINED - Not Corrected
Whirlpool sand filter is leaking at the base.
Correction: Repair and maintain the whirlpool sand filter.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model. installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: Operator unsure if valves
-
Nov 14, 2024 Routine Inspection · Reinspection Required
-
Not serious
Action taken: Operator unsure if valves
05a - SKIMMER/MAIN DRAIN RATIO
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Operator adjusted chlorine
Corrected on site
14a - CHLORINE TOO LOW
The chlorine residual was 2.6ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to 3.0. Call inspector to schedule a reopening inspection.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken: Operator will begin testin
14e - WATER POTENTIAL ORP
The water potential was 121 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: Hardware installed.
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE
Sheppard's crook is missing hardware that connects head to pole.
Correction: Connect hook to pole with durable nuts and bolts or similar hardware.
Code ATCP 76.26(1)(a)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and/or the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken: Operator provided a second
Corrected on site
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area. One was available but second was not.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken: Discussed with operator.
29d - DECK DISINFECTION
The deck is not being sanitized weekly.
Correction: Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
Whirlpool sand filter is leaking at the base.
Correction: Repair and maintain the whirlpool sand filter.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model. installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Other
41c - MISCELLANEOUS
Whirlpool jet timer runs for more than 15 minutes.
Correction: Repair or replace timer so that the maximum time is 15 minutes.
Code SPS390.21(7)
-
Not serious
Action taken: Operator unsure if valves
-
Mar 6, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
04c - SKIMMER BASKET/WEIR
The whirlpool skimmer weir door is missing.
Correction: Replace missing weir door and maintain.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: sanitarian emailed copy of
16d - COMBINED CHLORINE
The combined chlorine is 0.6 ppm.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Action taken: water testing fact sheet p
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). Operator has not been testing/recording for combined chlorine.
Correction: Perform water testing in accordance with ATCP 76.18(2). Test/record reading for combined chlorine 1x/day for the whirlpool.
Code ATCP 76.18(2)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for pH and free chlorine are not in compliance with ATCP 76.18(3). Strantrol Set Point NX controller shows HRR at 54 and pH at 8.4. Pool operator indicated he needs to replace the probes and has new probes onsite.
Correction: Perform water testing in accordance with ATCP 76.18(3). If electronic controller shows HRR (ORP) outside of range 650-850mv, test whirlpool pH and free chlorine 4x/day.
Code ATCP 76.18(3)
-
Not serious
Action taken: Brian found a replacement
Corrected on site
33a - HAZARDOUS MATERIAL
Main drain cover nearest to the steps was missing a screw at the time of the inspection.
Correction: Immediately replace missing screw for main drain cover.
Code ATCP 76.34(1)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Receipts from purchase of covers available, but VGBA log was not updated.
Correction: Update VGBA log to maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Oct 6, 2022 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET - Not Corrected
A spare strainer basket is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER - Not Corrected
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Sep 30, 2022 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
14a - CHLORINE TOO LOW
The chlorine residual was 0ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to 1-10ppm Call inspector to schedule a reopening inspection.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken:
16d - COMBINED CHLORINE
The combined chlorine is 2ppm.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 26, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Mar 19, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Oct 19, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Mar 6, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Oct 5, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Dec 16, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Mar 10, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jan 14, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Feb 27, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.