RecordWell Data

Holiday Inn Hotel & Suites

1109 FOURIER DR, Madison, WI 53717 · Dane County

57cited violations
0serious tier
20inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
58835-54442
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262130
2025120
20242160
20232190
2022370
2020200
2019100
2018100
2017100
2015100
2014200
2013100
2012100

Inspections

  1. Jun 24, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER (P - Not Corrected

      The flow meter is not functional or installed properly.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious POOL SLIDES AND WATERSLIDES. For the plu

      27h - SIGNAGE - SLIDE RULES - Not Corrected

      Pool slide rules under ATCP 76.29(2) are not posted.

      Correction: Provide an approved sign.

      Code ATCP 76.29(2)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      Documentation available onsite for VGBA main drain and/or equalizer covers shows equalizer covers expired June 2024 per receipt. Operator states covers are being replaced when damaged but is not keeping a record of when new covers are installed.

      Correction: Replace all expired equalizer covers. Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers onsite and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Cover appears intact, secure, and fits properly. A daily i

      Code ATCP 76.38

    • Not serious Action taken:

      39a - WATER ATTRACTION - MAINTANED SAFE (P) - Not Corrected

      Handrail on stairs leading to waterslide is loose.

      Correction: Repair and maintain in accordance with recognized safe practices.

      Code ATCP 76.37(1)(a)

  2. Jun 24, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04a - SKIMMER FUNCTION (Pf)

      The skimmer on the side of the plunge pool (middle basin) closest to the shower rooms is not adequately removing surface debris.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken: Discussed with operator th

      08b - RECIRCULATION RATE - WATER ATTRACTION (Pf)

      The water attraction exceeds the required turnover rate indicated in Table ATCP 76.11-A for plunge pool types of 1.0. Turnover rate calculated to be 1.84.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional or installed properly.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious POOL SLIDES AND WATERSLIDES. For the plu

      27h - SIGNAGE - SLIDE RULES

      Pool slide rules under ATCP 76.29(2) are not posted.

      Correction: Provide an approved sign.

      Code ATCP 76.29(2)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      Documentation available onsite for VGBA main drain and/or equalizer covers shows equalizer covers expired June 2024 per receipt. Operator states covers are being replaced when damaged but is not keeping a record of when new covers are installed.

      Correction: Replace all expired equalizer covers. Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers onsite and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Cover appears intact, secure, and fits properly. A daily i

      Code ATCP 76.38

    • Not serious Action taken: Waterslide closed for repa

      37b - HAZARDOUS PROJECTION (P)

      Shard edges exist at seated position on waterslide where a patron may come into contact with. Fiberglass coating is chipping and cracking.

      Correction: Eliminate the hazardous condition using recognized safe practices.

      Code ATCP 76.36(1)(b)

    • Not serious Action taken:

      39a - WATER ATTRACTION - MAINTANED SAFE (P)

      Handrail on stairs leading to waterslide is loose.

      Correction: Repair and maintain in accordance with recognized safe practices.

      Code ATCP 76.37(1)(a)

  3. May 8, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04a - SKIMMER FUNCTION (Pf)

      The skimmer on the side of the plunge pool (middle basin) closest to the shower rooms is not adequately removing surface debris.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken: Discussed with operator th

      08b - RECIRCULATION RATE - WATER ATTRACTION (Pf)

      The water attraction exceeds the required turnover rate indicated in Table ATCP 76.11-A for plunge pool types of 1.0. Turnover rate calculated to be 1.84.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c)

  4. Feb 28, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken: On 2-28-2024, reagent has

      20a - TEST KIT NOT APPROVED - Not Corrected

      The test kit used by the facility missing DEOX reagent for non-chlorine shock chemical.

      Correction: Maintain testing kit to accurately test pool water for combined chlorine.

      Code ATCP 76.17(1)

    • Not serious POOL SLIDES AND WATERSLIDES. For the plu

      27h - SIGNAGE - SLIDE RULES - Not Corrected

      Pool slide rules under ATCP 76.29(2) are not posted.

      Correction: Provide an approved sign.

      Code ATCP 76.29(2)

    • Not serious Action taken: Monthly report of daily op

      28d - MONTHLY REPORTS AVAILABLE - Not Corrected

      A fecal incident response plan, manual for filter operation and manual for pool slide operation and maintenance are not available for review. Monthly reports of daily pool operation are not completed on approved forms.

      Correction: Keep records available for review. Submit copy of pool slide operation and maintenance to sanitarian.

      Code ATCP 76.32(3)

    • Not serious Action taken: on 2-28-2024, basin cleane

      29b - BASIN DEFECTS - Not Corrected

      Sand or dirt in pool basin. Plaster chipped at ladder stair.

      Correction: Routinely vacuum to keep basin free of sediment. Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

  5. Feb 15, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility such non-chlorine shock and Taylor reagents.

      Correction: Inventory chemicals and provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      20a - TEST KIT NOT APPROVED

      The test kit used by the facility missing DEOX reagent for non-chlorine shock chemical.

      Correction: Maintain testing kit to accurately test pool water for combined chlorine.

      Code ATCP 76.17(1)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2/week and alkalinity 1/week. Use State monthly reports with controllers reporting form.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN

      Lifeguard staffing plan requires updating. Surface area is incorrect for all three pools listed on plan. Adjust lifeguard staffing placement for both average and maximum capacity for the plunge pool. Max capacity for plunge pool is 75. Staffing plan indicates life guard staffing up to max capacity 150. Include attendant requirements for whirlpool and wading pool. Include all obstructions on plan.

      Correction: Update the written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken: Lifeguard returned to life

      24c - LIFEGUARD - INADEQUATE

      Lifeguard is not present where required by staffing plan. Lifeguard left station when patrons were in pool.

      Correction: All or portions of the facility must be closed until compliance with ATCP 76.23(1) is achieved.

      Code ATCP 76.23(1)(a)

    • Not serious Action taken:

      26g - PATRON LOAD - TOO HIGH

      The posted maximum patron load exceeds the legal requirements as described on the pool rules sign. Other patron load signage is correct.

      Correction: Remove incorrect patron load from pool rules sign.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      Biohazard safety kit is damaged.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious POOL SLIDES AND WATERSLIDES. For the plu

      27h - SIGNAGE - SLIDE RULES

      Pool slide rules under ATCP 76.29(2) are not posted.

      Correction: Provide an approved sign.

      Code ATCP 76.29(2)

    • Not serious Action taken: Monthly report of daily op

      28d - MONTHLY REPORTS AVAILABLE

      A fecal incident response plan, manual for filter operation and manual for pool slide operation and maintenance are not available for review. Monthly reports of daily pool operation are not completed on approved forms.

      Correction: Keep records available for review. Submit copy of pool slide operation and maintenance to sanitarian.

      Code ATCP 76.32(3)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      Sand or dirt in pool basin. Plaster chipped at ladder stair.

      Correction: Routinely vacuum to keep basin free of sediment. Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      30e - SOAP

      The soap dispensers at shower stalls in men's and women's restrooms are empty.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

  6. Jan 25, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Operator suspects Taylor k

      16d - COMBINED CHLORINE - Not Corrected

      The combined chlorine is 1.2 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN - Not Corrected

      The lifeguard staffing plan has incorrect surface area, outdated operational hours, is missing the average capacity lifeguard staffing on the diagram, and the third guard on the diagram is placed to watch the wading pool, not the guarded main pool.

      Correction: Update the written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken: Pad ordered.

      26q - FIRST AID KIT - SUPPLIES MISSING - Not Corrected

      8"x10" gauze pad is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken: Facility states they are a

      29b - BASIN DEFECTS - Not Corrected

      The pool basin floor is eroded in spots around the basketball hoop area.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken: Facility states they are a

      29f - DEPTH MARKINGS VISIBLE - Not Corrected

      The depth markings along the inside edge of the pool are fading or otherwise not visible.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing originally installed make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Engineer scheduled to insp

      36c - WATERSLIDE - ENGINEER INSPECTION - Not Corrected

      There is no documentation available that the water attraction has had an inspection by an engineer within the last five years.

      Correction: Contact an engineer and schedule an inspection immediately. Every five years all waterslides shall be evaluated by an engineer for the structural stability and integrity of the slide and platform. A copy of a report signed by the engineer shall be kept on site.

      Code ATCP 76.37(2)(c)

  7. Jan 18, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      11a - CHEMICAL - LABELING

      Large chlorine tub is not labeled according to ATCP 76.12(1). Tub is labeled with name of product only.

      Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number.

      Code ATCP 76.12(1)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.4 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN

      The lifeguard staffing plan has incorrect surface area, outdated operational hours, is missing the average capacity lifeguard staffing on the diagram, and the third guard on the diagram is placed to watch the wading pool, not the guarded main pool.

      Correction: Update the written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken:

      26g - PATRON LOAD - TOO HIGH

      The maximum patron load posted in the facility is too high. 150 is posted, plans show actual maximum load is 75 persons.

      Correction: Post the maximum patron load per original plans.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      8"x10" gauze pad is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken: Facility states they are a

      29b - BASIN DEFECTS

      The pool basin floor is eroded in spots around the basketball hoop area.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken: Facility states they are a

      29f - DEPTH MARKINGS VISIBLE

      The depth markings along the inside edge of the pool are fading or otherwise not visible.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken: Door locked and is now lat Corrected on site

      34c - DOOR/GATE

      The main door to the pool enclosure is not self-latching. When unlocked, door does not latch.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing originally installed make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      36c - WATERSLIDE - ENGINEER INSPECTION

      There is no documentation available that the water attraction has had an inspection by an engineer within the last five years.

      Correction: Contact an engineer and schedule an inspection immediately. Every five years all waterslides shall be evaluated by an engineer for the structural stability and integrity of the slide and platform. A copy of a report signed by the engineer shall be kept on site.

      Code ATCP 76.37(2)(c)

  8. Mar 29, 2022 Re-Inspection · No Reinspection Required

    No violations cited.

  9. Jan 28, 2022 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER - Not Corrected

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16d - COMBINED CHLORINE - Not Corrected

      The combined chlorine is 1.6 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      30e - SOAP - Not Corrected

      The soap dispensers are missing in the buoys shower area.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

  10. Jan 24, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.6 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      26m - TELEPHONE - NOT WORKING

      The emergency telephone is not working.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      30e - SOAP

      The soap dispensers are missing in the buoys shower area.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

  11. Feb 14, 2020 Re-Inspection · No Reinspection Required

    No violations cited.

  12. Jan 24, 2020 Routine Inspection · Reinspection Required

    No violations cited.

  13. Feb 13, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Feb 2, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  15. Mar 6, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  16. Aug 17, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  17. Dec 10, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  18. Jan 14, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  19. Feb 18, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  20. Feb 14, 2012 Routine Inspection · Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.