RecordWell Data

Holiday Inn Hotel & Suites

1109 Fourier DR, Madison, WI 53717 · Dane County

31cited violations
0serious tier
16inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWM-2010-00366
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026120
2025110
20242150
20232120
2022110
2020100
2019100
2018100
2017100
2015100
2014200
2013100
2012100

Inspections

  1. Jun 24, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

  2. May 8, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

  3. Feb 28, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken: On 2-28-2024, reagent orde

      20a - TEST KIT NOT APPROVED - Not Corrected

      The test kit used by the facility missing DEOX reagent for non-chlorine shock chemical.

      Correction: Maintain testing kit to accurately test pool water for combined chlorine.

      Code ATCP 76.17(1)

    • Not serious Action taken: Monthly report of daily op

      28d - MONTHLY REPORTS AVAILABLE - Not Corrected

      A fecal incident response plan, manual for filter operation, and manuals for operation and maintenance for children's slides are not available for review. Monthly reports of daily pool operation are not completed on approved forms.

      Correction: Keep records available for review.

      Code ATCP 76.32 (1) and (3)

  4. Feb 15, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04b - SKIMMERS/GUTTERS CLEANED

      Skimmers are not clean. Plastic, hair, toys and goggles found in skimmer baskets.

      Correction: Maintain in a clean condition.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Weir is missing at 12 inch water depth marker.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Water level adjusted durin Corrected on site

      05b - WATER LEVEL

      The pool water level is not adequate for continuous effective surface skimming. Water level too high above weir door.

      Correction: Adjust the water level until the skimming of the water surface is adequate.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility such as non-chlorine shock and Taylor reagents.

      Correction: Inventory chemicals and provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken: Chemical adjustment made d Corrected on site

      16a - pH

      The pH is 7.0

      Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Action taken:

      20a - TEST KIT NOT APPROVED

      The test kit used by the facility missing DEOX reagent for non-chlorine shock chemical.

      Correction: Maintain testing kit to accurately test pool water for combined chlorine.

      Code ATCP 76.17(1)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for combined chlorine and alkalinity are not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2/week and alkalinity 1/week. Use State monthly reports with controllers reporting form.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN

      The facility does not have a lifeguard and/or attendant staffing plan for the wading pool with visual obstruction with cross section view of greater than 50 square feet. Facility has domed mirrors but no approved variance for alternate method of coverage. Surface area is incorrect for all three pools listed on plan. Adjust lifeguard staffing plan to include attendant requirements for whirlpool and wading pool. Include all obstructions on plan.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval. At least one attendant is required for a wading pool with a visual obstruction unless an approved variance for alternate method of coverage can be obtained.

      Code ATCP 76.22(1)(a); DSPS 390.31(3)

    • Not serious Action taken:

      26g - PATRON LOAD - TOO HIGH

      The posted maximum patron load exceeds the legal requirements as described on the pool rules sign. Other patron load signage is correct.

      Correction: Remove incorrect patron load from pool rules sign.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      Biohazard safety kit is damaged.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken: Monthly report of daily op

      28d - MONTHLY REPORTS AVAILABLE

      A fecal incident response plan, manual for filter operation, and manuals for operation and maintenance for children's slides are not available for review. Monthly reports of daily pool operation are not completed on approved forms.

      Correction: Keep records available for review.

      Code ATCP 76.32 (1) and (3)

    • Not serious Action taken:

      30e - SOAP

      The soap dispensers at shower stalls in men's and women's restrooms are empty.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

  5. Jan 25, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Ordered per operator.

      26q - FIRST AID KIT - SUPPLIES MISSING - Not Corrected

      8"x10" gauze pad is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing originally installed make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Jan 18, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      05a - SKIMMER/MAIN DRAIN RATIO

      The skimmer to main drain flow ratio is not set correctly. Main drain is set at about 60% open.

      Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      11a - CHEMICAL - LABELING

      Large chlorine and acid tubs are not labeled according to ATCP 76.12(1). Tubs labeled with name of product only.

      Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number.

      Code ATCP 76.12(1)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      A pool basin in the facility does not have a 'No Lifeguard on Duty' sign.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters in the wading pool area.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken:

      26g - PATRON LOAD - TOO HIGH

      The maximum patron load posted in the facility is too high. 150 is posted, plans show actual maximum load is 74 persons.

      Correction: Post the maximum patron load per original plans.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      8"x10" gauze pad is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken: Door locked and is now lat Corrected on site

      34c - DOOR/GATE

      The main door to the pool enclosure is not self-latching. When unlocked, door does not latch.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing originally installed make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      37b - HAZARDOUS PROJECTION

      Screws on side walls at top of back slide on ship play feature are exposed instead of being inset, and have sharp edges.

      Correction: Eliminate the hazardous projection using recognized safe practices.

      Code ATCP 76.36(1)(b)

  7. Jan 24, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

  8. Jan 24, 2020 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Feb 13, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Feb 2, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Mar 6, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Aug 17, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Dec 10, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Jan 14, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  15. Feb 18, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  16. Feb 14, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.