Landing
6409 BRIDGE RD, Madison, WI 53713 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 9724-2351
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 1 | 4 | 0 |
| 2024 | 1 | 9 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2015 | 2 | 0 | 0 |
| 2014 | 2 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Aug 13, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken: In order to avoid a charge
Repeat
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for alkalinity, combined chlorine and cyanuric acid, is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Aug 9, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: PIC adjusted onsite.
Corrected on site
05a - SKIMMER/MAIN DRAIN RATIO
The skimmer to main drain flow ratio is not set correctly. Both are set wide open.
Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
08a - RECIRCULATION RATE - SWIM/COMBO
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(a)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE
The test kit reagents are expired.
Correction: Keep reagents in original containers and replace as recommended by manufacturer.
Code ATCP 76.17(2)
-
Not serious
Action taken: Use updated pool logs with
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for alkalinity and combined chlorine is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: PIC found Shepherd's Crook
Corrected on site
26i - RESCUE EQUIPMENT - MISSING
A Sherpherd's Crook is not provided in the pool area.
Correction: Provide a Shepherd's Crook for the facility and mount it in a conspicuous location.
Code ATCP 76.26(1)(b)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Eye wash is missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken: PIC immediately repaired b
Corrected on site
34c - DOOR/GATE
The gates to the pool enclosure are not consistently self-closing and self-latching. The gate on one side can be propped open as the bottom bars get stuck on the concrete. The other gate does not always latch when there is not sufficient momentum to reach the latch.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. The PIC dove down and took a picture of the main drains, the 2017 VGBA stamp was visible as well as a model # and possibly a manufacturer date of 2019. The main drains and equalizers covers appear to be in good condition.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: PIC adjusted onsite.
Corrected on site
-
Jun 25, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 26, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 1, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 2, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 19, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 1, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 11, 2014 Reinspection · No Reinspection Required
No violations cited.
-
Jun 20, 2014 Routine Inspection · Reinspection Required
No violations cited.
-
Sep 5, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.