Madison, The

5440 CONGRESS AVE, Madison, WI 53718 · Dane County

10cited violations
0serious tier
14inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
63205-61860
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025110
2023120
2022270
2021100
2019100
2018100
2017200
2016100
2015200
2013100
2012100

Inspections

  1. Jun 23, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). Combined chlorine test is not being done.

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test combined chlorine level daily.

      Code ATCP 76.18(2)

  2. Jul 27, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      11a - CHEMICAL - LABELING

      The chlorine tank is not labeled according to ATCP 76.12(1).

      Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number.

      Code ATCP 76.12(1)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE

      The water testing frequency for combined chlorine and total alkalinity is not in compliance with ATCP.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test total alkalinity at least once a week. Test combined chlorine level at least once daily.

      Code ATCP 76.18(2)

  3. Jul 14, 2022 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE - Not Corrected

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). The operator is not completing the combined chlorine test. There were no water test entries on the log for 7/2/22, 7/3/22, and 7/4/22.

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test for combined chlorine at least once daily. Test for pH and free Chlorine at least four times per day--before the pool is in use and at least twice when the pool is in use. Test for total alkalinity at least once per week. If planning to use stabilizer, test cyanuric acid level at least once per week.

      Code ATCP 76.18(2)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Jul 13, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      14c - CHLORINE TOO HIGH

      The chlorine residual exceeded 10 ppm. The chlorine residual was 17.0 ppm.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.0 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). The operator is not completing the combined chlorine test. There were no water test entries on the log for 7/2/22, 7/3/22, and 7/4/22.

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test for combined chlorine at least once daily. Test for pH and free Chlorine at least four times per day--before the pool is in use and at least twice when the pool is in use. Test for total alkalinity at least once per week. If planning to use stabilizer, test cyanuric acid level at least once per week.

      Code ATCP 76.18(2)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 23, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Aug 28, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jun 4, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 22, 2017 Re-Inspection · No Reinspection Required

    No violations cited.

  9. Jun 15, 2017 Routine Inspection · Reinspection Required

    No violations cited.

  10. Jun 1, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jun 19, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jun 19, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jul 29, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Jul 11, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.