RecordWell Data

Marriott Madison West Hotel

1313 JOHN Q HAMMONS DR, Middleton, WI 53562 · Dane County

47cited violations
0serious tier
16inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
73090-81273
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262360
2023290
2022220
2019300
2017200
2015200
2014100
2013100
2012100

Inspections

  1. Apr 20, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      02a - LICENSE POSTED PUBLIC VIEW - Not Corrected

      The license is not posted in a place visible to the public.

      Correction: Post the license in public view.

      Code ATCP 76.05(7)

    • Not serious Action taken: As of 4/20/2026, Screen fo

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket(s) or screen for the skimmers and the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket(s) or screen for the skimmers are not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      10b - BACKWASH - SAND FILTER (Pf) - Not Corrected

      Backwash procedures are not conspicuously posted in the filter area.

      Correction: Post pool backwash procedures in a conspicuous place in the filter area and backwash the sand filter in accordance manufacturer's instructions.

      Code ATCP 76.11(6)(a)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf) - Not Corrected

      Doors to chemical storage area is not marked to indicate entry is for authorized personnel only.

      Correction: Mark doors to chemical storage area for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken: Combined chlorine plan tem

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf) - Not Corrected

      The water testing frequency for combined chlorine and alkalinity is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine 2/week and alkalinity 1/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP - Not Corrected

      The water testing frequency for alkalinity and combined chlorine are not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2/week and alkalinity 1/week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      22a - THERMOMETER (Pf) - Not Corrected

      There is no functional or visible thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Action taken: As of 4/20/2026. sign orde

      26g - BREATH HOLDING PROHIBITION - SIGNAGE - Not Corrected

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf) - Not Corrected

      Emergency pool phone rings front desk. Instructions are not provided on how to dial front desk.

      Correction: Post the emergency numbers near or attached to the designated emergency phone. Ensure calls are picked up within 2 rings at the front desk, staff are trained on emergency procedures, do not have distractive duties, and do not use cordless phone to leave desk. Post emergency instructions, numbers, and address at front desk.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING - Not Corrected

      Tweezers, eye wash and larger 8 inch x 10 inch gauze pads are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected

      Several items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious a. Do not enter the pool if you have a c

      27e - SIGNAGE - POOL RULES - Not Corrected

      Some pool rules are missing from the posted rules.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b).

      Code ATCP 76.29(1)(b)

    • Not serious 1. Do not enter the pool if you have a c

      27e - SIGNAGE - POOL RULES - Not Corrected

      Posted pool rules are missing compliant pool rule language.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b) in 1-inch lettering.

      Code ATCP 76.29(1)(b)

    • Not serious Action taken:

      28d - MONTHLY REPORTS AVAILABLE - Not Corrected

      Pump curve is not available for review.

      Correction: Keep records available for review.

      Code ATCP 76.32(3)

    • Not serious Action taken: Updated report provided wi

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      Monthly operating record does not include monthly pump and safety checks.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: Link to forms provided wit

      28f - FILES MAINTAINED - Not Corrected

      Several files are not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3). 1. A copy of the most current version of ch. ATCP 76. 2. For pools constructed after July 1, 2023, a copy of the Wisconsin department of safety and professional services approved pool constructions plans, including Virginia Graeme Baker Act plan approvals. 3. The manufacturer's pump performance curve. 4. The manual of operations for any secondary anti-e

      Code ATCP 76.32(3)

    • Not serious Action taken:

      29b - BASIN DEFECTS - Not Corrected

      The paint is fading and the deep end corner of the pool basin appear discolored.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29d - DECK DISINFECTION - Not Corrected

      Deck is unclean with leaves and water stain from planter.

      Correction: Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED - Not Corrected

      Pump is leaking and reagent kit comparator is no longer clear.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken: As of 4/20/2026, (1) pool

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED - Not Corrected

      (1) Underwater pool lighting is non-functional. (2) Reagent kit comparator is no longer clear. (3) Drinking fountain is not available.

      Correction: Repair underwater pool lighting and replace reagent kit comparator. Install drinking fountain in pool area.

      Code ATCP 76.33(1)(e-g)

  2. Apr 7, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      02a - LICENSE POSTED PUBLIC VIEW

      The license is not posted in a place visible to the public.

      Correction: Post the license in public view.

      Code ATCP 76.05(7)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers and the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      10b - BACKWASH - SAND FILTER (Pf)

      Backwash procedures are not conspicuously posted in the filter area.

      Correction: Post pool backwash procedures in a conspicuous place in the filter area and backwash the sand filter in accordance manufacturer's instructions.

      Code ATCP 76.11(6)(a)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Doors to chemical storage area is not marked to indicate entry is for authorized personnel only.

      Correction: Mark doors to chemical storage area for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken: Combined chlorine plan tem

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for combined chlorine and alkalinity is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine 2/week and alkalinity 1/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      22a - THERMOMETER (Pf)

      There is no functional or visible thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf)

      Emergency pool phone rings front desk. Instructions are not provided on how to dial front desk.

      Correction: Post the emergency numbers near or attached to the designated emergency phone. Ensure calls are picked up within 2 rings at the front desk, staff are trained on emergency procedures, do not have distractive duties, and do not use cordless phone to leave desk. Post emergency instructions, numbers, and address at front desk.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Several items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious a. Do not enter the pool if you have a c

      27e - SIGNAGE - POOL RULES

      Some pool rules are missing from the posted rules.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b).

      Code ATCP 76.29(1)(b)

    • Not serious Action taken: Updated report provided wi

      28e -REPORTS AND RECORDS (Pf)

      Monthly operating record does not include monthly pump and safety checks.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: Link to forms provided wit

      28f - FILES MAINTAINED

      Several files are not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3). 1. A copy of the most current version of ch. ATCP 76. 2. For pools constructed after July 1, 2023, a copy of the Wisconsin department of safety and professional services approved pool constructions plans, including Virginia Graeme Baker Act plan approvals. 3. The manufacturer's pump performance curve. 4. The manual of operations for any secondary anti-e

      Code ATCP 76.32(3)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      (1) Underwater pool lighting is non-functional. (2) Reagent kit comparator is no longer clear. (3) Drinking fountain is not available.

      Correction: Repair underwater pool lighting and replace reagent kit comparator. Install drinking fountain in pool area.

      Code ATCP 76.33(1)(e-g)

  3. Dec 28, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers are not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for alkalinity and combined chlorine are not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2/week and alkalinity 1/week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      Tweezers, eye wash and larger 8 inch x 10 inch gauze pads are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious 1. Do not enter the pool if you have a c

      27e - SIGNAGE - POOL RULES

      Posted pool rules are missing compliant pool rule language.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b) in 1-inch lettering.

      Code ATCP 76.29(1)(b)

    • Not serious Action taken:

      28d - MONTHLY REPORTS AVAILABLE

      Pump curve is not available for review.

      Correction: Keep records available for review.

      Code ATCP 76.32(3)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      The paint is fading and the deep end corner of the pool basin appear discolored.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29d - DECK DISINFECTION

      Deck is unclean with leaves and water stain from planter.

      Correction: Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Pump is leaking and reagent kit comparator is no longer clear.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  4. Mar 30, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

  5. Mar 9, 2022 Re-Inspection · No Reinspection Required

    No violations cited.

  6. Mar 7, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      34a - GATES NOT MAINTAINED

      The conference area door to the pool enclosure is not being maintained.

      Correction: Repair and maintain the gate or door.

      Code ATCP 76.34(2)

  7. Oct 14, 2019 Re-Inspection · No Reinspection Required

    No violations cited.

  8. Sep 26, 2019 Routine Inspection · Reinspection Required

    No violations cited.

  9. Jun 28, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Dec 19, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  11. May 30, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Sep 23, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jan 14, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Feb 21, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  15. Jan 9, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  16. Jan 5, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.