RecordWell Data

Oliv Madison

339 W Gorham ST, Madison, WI 53703 · Dane County

5cited violations
0serious tier
2inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2025-00597
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026140
2025110

Inspections

  1. Jun 10, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04a - SKIMMER FUNCTION (Pf)

      The skimmer on the Southwest corner of the outdoor whirlpool is more effective than the other skimmers in the basin, which are not adequately removing surface debris, as there was some accumulation of plant debris present on the South side of the outdoor whirlpool. The skimmer located on the Northeast corner of the outdoor whirlpool appeared to be the least effective.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 633 - 642 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: Operator relocated shepher Corrected on site

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)

      Shepherd's crook is on site, but is not readily accessible, as it is located in taller grass behind a bench on the South side of the outdoor pool basin.

      Correction: Mount properly sized [equipment], position in a consipicuous place that is readily accessible, and maintain in good repair.

      Code ATCP 76.26(1)

    • Not serious Action taken: Operator fixed phone at ti Corrected on site

      26n - TELEPHONE - NOT WORKING (P)

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

  2. Aug 4, 2025 Pre-Inspection · No Reinspection Required
    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.