Palisade Apartments
535 W Johnson ST, Madison, WI 53703 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2024-00163
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 15 | 0 |
| 2025 | 2 | 14 | 0 |
| 2024 | 1 | 0 | 0 |
Inspections
-
Aug 21, 2026 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Template provided. At RI#1
Corrected on site
16d - COMBINED CHLORINE (Pf) - Not Corrected
The operator does not have a combined chlorine plan or is not following combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
28e -REPORTS AND RECORDS (Pf) - Not Corrected
Operating record is not complete.
Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall
Code ATCP 76.32(1)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN (P) - Not Corrected
The drinking fountain is not provided.
Correction: Provide a plumbed drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken: ordered
30e - SOAP (Pf) - Not Corrected
The soap dispenser is empty at handwash and shower.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. Main drain covers appear secure and intact.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Check main drain covers daily for defects. Close pool immediately if any defects are observed.
Code ATCP 76.38
-
Not serious
Action taken: Template provided. At RI#1
Corrected on site
-
Aug 17, 2026 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
05a - SKIMMER/MAIN DRAIN RATIO (Pf)
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) or screen for the recirculation pump is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken: Chemical release training
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demostrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: Template provided.
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan or is not following combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
26n - TELEPHONE - NOT WORKING (P)
The emergency telephone does not work.
Correction: Provide a functional emergency telephone. Pool to remain closed until emergency telephone is verified functional by Health Department.
Code ATCP 76.26(2)
-
Not serious
Action taken:
28e -REPORTS AND RECORDS (Pf)
Operating record is not complete.
Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall
Code ATCP 76.32(1)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN (P)
The drinking fountain is not provided.
Correction: Provide a plumbed drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
30e - SOAP (Pf)
The soap dispenser is empty at handwash and shower.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Recirculation pump strainer is not installed.
Correction: Install strainer in recirculation pump and clean according to manufacture's instructions.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. Main drain covers appear secure and intact.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Check main drain covers daily for defects. Close pool immediately if any defects are observed.
Code ATCP 76.38
-
Not serious
Action taken:
-
Aug 29, 2025 Re-Inspection · No Reinspection Required
No violations cited.
-
Aug 21, 2025 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket skimmers is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf)
Safety data sheets are not available for pool chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Office PIC printed interlo
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken: PIC in office printed DATC
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken: Discard expired text kit a
20b - TEST KIT REAGENT STORAGE (Pf)
The test kit reagents onsite are past their expiration date.
Correction: Store reagents properly, in original containers, replace when expired.
Code ATCP 76.17(2)
-
Not serious
Action taken: Sanitarian tested with ope
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency is not in compliance with ATCP 76.18(3). No manual water testing is documented for the basin. The operator notes the ORP and pH from the electronic monitoring device daily.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: Responsible supervisor als
Corrected on site
23d - NO RESPONSIBLE SUPERVISOR (P)
Responsible supervisor is not performing duties as required in 76.21. Daily water testing is not conducted, maintenance staff tasked with testing not trained, monthly interlock testing is not conducted, and records are not maintained. Number for responsible supervisor not posted by the emergency phone.
Correction: The pool must be closed until a responsible supervisor is available to fulfill the responsibilities.
Code ATCP 76.21
-
Not serious
Action taken:
25n - LIFEGUARD - SIGNAGE (Ppf)
The lifeguard on duty signage lettering is less than 4 inches.
Correction: Post an approved sign with letters at least 4 inches high stating: "Warning: No Lifeguard on Duty."
Code ATCP 76.23(2)
-
Not serious
Action taken: Submit a variance applicat
26m - TELEPHONE - NO CONNECTION TO EMERGENCY SERVICES (P)
The push button pool phone does not directly connect to emergency services. When tested the connection is clear and loud and connects to a dispatch center that informed they are staffed 24/7.
Correction: Provide a telephone capable of connecting with emergency services at all times during pool operation or apply for a variance.
Code ATCP 76.26(2)(a)
-
Not serious
Action taken: Operator located first aid
Corrected on site
26q - FIRST AID KIT - AVAILABLE (P)
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)(a)
-
Not serious
Action taken: Blankets located in pump r
Corrected on site
26s - BLANKETS MISSING (Pf)
2 conventional or emergency blankets are not available in the pool area.
Correction: Provide 2 conventional or emergency blankets in the pool area.
Code ATCP 76.27(1)(3)
-
Not serious
Action taken:
30e - SOAP (Pf)
The soap dispenser by the hand sink is empty and the shower does not have soap.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Jun 5, 2024 Pre-Inspection · No Reinspection Required
No violations cited.