RecordWell Data

Stonewood Village Apartments

302 Parkwood LN 1, Madison, WI 53714 · Dane County

7cited violations
0serious tier
4inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2023-00539
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026110
2025130
2023230

Inspections

  1. Jun 18, 2026 Routine Inspection · No Reinspection Required
    • Not serious 1. The interlock device shall meet all o

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

  2. Jun 5, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf)

      2 conventional or emergency blankets are not available in the pool area.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      26t - BIOHAZARD SAFETY KIT (Pf)

      No biohazard safety kit is located at the first aid station or on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. Drain cover: Neptune Benson 30'' x 30'' #3030AEC, 15 year lifespan, was due for replacement by May 2025.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Replace main drain cover.

      Code ATCP 76.38

  3. Jul 21, 2023 Re-Inspection · No Reinspection Required

    No violations cited.

  4. Jul 20, 2023 Pre-Inspection · Reinspection Required
    • Not serious Action taken:

      20a - TEST KIT NOT APPROVED

      The test kit used by the facility has a few expired reagents.

      Correction: Replace the expired reagents in the test kit.

      Code ATCP 76.17(1)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1). The combined chlorine test is only being tested once per week, not twice per week.

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test for combined chlorine twice per week.

      Code ATCP 76.18(1)

    • Not serious Any of the following conditions or situa

      28a - CLOSING CRITERIA

      The pool was not closed under the following condition: missing screw on main drain cover which is an immediate danger to safety.

      Correction: Ensure that the closing criteria are adhered to under the listed below. Close the pool.

      Code ATCP 76.30

Source: Public Health Madison & Dane County. History last read Oct 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.