RecordWell Data

The Addison

2676 NORTH PARK LN, Fitchburg, WI 53711 · Dane County

19cited violations
0serious tier
12inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2015-00247
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026150
2025190
2024110
2022240
2021100
2019100
2018300
2017100
2015100

Inspections

  1. Aug 25, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional and bobber is stuck on the bottom of the gauge.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: PIC printed and completed Corrected on site

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Documentation of interlock system tests per requirements in ATCP 76.13(1)(c) is not available onsite.

      Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 40ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: PIC printed template from Corrected on site

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: PIC informed that plans ar

      34d - DOOR/GATE (P)

      Both gates to the pool enclosure require an electronic fob to exit the pool enclosure.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  2. Jul 16, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Sanitarian to provide temp

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Discussed adding to existi

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Sanitarian to provide docu

      26m - TELEPHONE - NO CONNECTION TO EMERGENCY SERVICES (P)

      The pool phone is a VOIP push button phone which requires a variance. When tested, pool phone dialed direct to 911 and the connection was clear.

      Correction: Provide a telephone capable of connecting with emergency services at all times during pool operation or apply for a variance.

      Code ATCP 76.26(2)(a)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Eyewash is expired in the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: Discussed signage requirem

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' is not posted in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA (P)

      The pool was not closed by the operator under the following condition: See (i) below.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken: Maintenance obtained CO de Corrected on site

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in garage area near the pool's fuel burning water heater.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken: 1) Corrected onsite. PIC r

      34d - DOOR/GATE (P)

      1) The gate closest to the pool house in not self-closing. 2) Both gates require an electronic fob or key to exit the pool enclosure.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      The VGBA log indicates that the main drains expired June 2025. The main drains show no visible signs of cracks, breaks, missing screws or other visible damage when inspected from outside the pool.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Jun 24, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

  4. Jul 15, 2022 Re-Inspection · No Reinspection Required
    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      VGBA main drain and equalizer log showing make/model present in pump room. Equalizers were installed in 2015 and have a 5 year expiration date. installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 13, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      06b - STRAINER BASKET CLEANED

      1 skimmer basket has debris and is not clean.

      Correction: Clean strainer baskets and screens daily to prevent the accumulation of debris.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work. When button is pressed, phone light blinks, but connection to 911 is not made.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Other

      34e - VGBA COVERS

      VGBA main drain and equalizer log showing make/model present in pump room. Equalizers were installed in 2015 and have a 5 year expiration date. installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Jul 14, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Aug 20, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Aug 22, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 5, 2018 Re-Inspection · No Reinspection Required

    No violations cited.

  10. Jun 1, 2018 Routine Inspection · Reinspection Required

    No violations cited.

  11. Jun 2, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Aug 14, 2015 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.