Conservancy Bend Residences
2409 PARMENTER ST, Middleton, WI 53562 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2021-00311
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 8 | 0 |
| 2025 | 2 | 11 | 0 |
| 2024 | 1 | 8 | 0 |
| 2022 | 1 | 3 | 0 |
| 2021 | 1 | 0 | 0 |
Inspections
-
Jun 23, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional. Flow meter is either stuck or flow rate exceeds scale of meter.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded. Flowmeter scale shall be readable.
Code ATCP 76.11(5)
-
Not serious
Action taken: Operator created list of e
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals storage room does not have a list of emergency telephone numbers.
Correction: Mark door to chemical storage areas to indicate entry is for authorized personnel only and keep doors locked. Provide a list of emergency telephone numbers in the chemical storage room, or have numbers readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken: Test log updated with corr
Corrected on site
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Interlock system testing is not documented per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system testing. Documentation shall include date, test results (i.e. "interlock ok" instead of only an "x"), name of tester, and any corrective action that was required.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for combined chlorine and cyanuric acid is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine daily and cyanuric acid once a week.
Code ATCP 76.18(3)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN
The statement indicating that children under the age of 12 shall be supervised by an adult does not have all letters at least 1 inch in height.
Correction: Add statement with all letters at least 1 inch tall indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b).
Code ATCP 76.29(1)(c)
-
Not serious
a. Do not enter the pool if you have a c
27e - SIGNAGE - POOL RULES
The following rules are missing from the posting: Shower immediately before entering the pool and after use of sauna or toilet facilities.
Correction: Provide a sign in compliance with ATCP 76.29(1)(b).
Code ATCP 76.29(1)(b)
-
Not serious
Action taken: Gate tension adjusted, now
Corrected on site
34d - DOOR/GATE (P)
The gate nearest to the leasing office to the pool enclosure is not self-latching; gate bounced open and didn't re-latch when closing with speed.
Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.
Code ATCP 76.34(4)
-
Not serious
Action taken:
-
Jun 25, 2025 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Operator created list of e
11b - CHEMICAL - STORAGE (P)(Pf) - Not Corrected
Chemicals storage room does not have a list of emergency telephone numbers.
Correction: Mark door to chemical storage areas to indicate entry is for authorized personnel only and keep doors locked. Provide a list of emergency telephone numbers in the chemical storage room, or have numbers readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN - Not Corrected
The statement indicating that children under the age of 12 shall be supervised by an adult does not have all letters at least 1 inch in height.
Correction: Add statement with all letters at least 1 inch tall indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b).
Code ATCP 76.29(1)(c)
-
Not serious
Action taken: Operator created list of e
-
Jun 17, 2025 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) skimmers is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals storage room door is not marked to indicate entry is for authorized personnel only and a list of emergency telephone numbers is not in the room.
Correction: Mark door to chemical storage areas to indicate entry is for authorized personnel only and keep doors locked. Provide a list of emergency telephone numbers in the chemical storage room, or have numbers readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system, which includes: a. Describes the location of chemical feed connections and system flow sensing interlocks in the recirculation system. P b. Describes how the chemical feeder electrical interlock functions. P c. Describes how the system flow sensing interlock functions, if applicable. P d. Describes how mo
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: Template emailed to operat
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine action plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
The biohazard safety kit is missing paper towels and a twist tie to close biohazard bag.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN
Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.
Correction: Add statement in letters at least 1 inch tall indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b).
Code ATCP 76.29(1)(c)
-
Not serious
Other
Corrected on site
27e - SIGNAGE - POOL RULES
Pool rules signs are not conspicuous; blocked by deck furniture.
Correction: Provide signage in a conspicuous place. Action taken: Deck furniture relocated, signs now visible and conspicuous.
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken:
-
Jun 25, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken: Barrels moved away from ea
Corrected on site
11b - CHEMICAL - STORAGE
Chemicals are improperly stored in accordance with ATCP 76.12(2). Barrels of chlorine and acid are stored touching each other.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE
The test kit reagents are expired: R-003 and R-004.
Correction: Keep reagents in original containers and replace upon expiration.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). Combined chlorine testing not being completed.
Correction: Perform water testing in accordance with ATCP 76.18(2). Test combined chlorine daily.
Code ATCP 76.18(2)
-
Not serious
Action taken: Shepherd's crook moved to
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE
Shepherd's crook is not conspicuous or ready accessible; being stored on ground between pool and fence where is it not easily visible.
Correction: Mount shepherd's crook in a readily accessible location within pool enclosure where it is visible.
Code ATCP 76.26(1)(a)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken:
28d - MONTHLY REPORTS AVAILABLE
Facility is not using current department provided daily testing log; using an older version.
Correction: Use current department provided testing log for recording all chemical testing.
Code ATCP 76.32(3)
-
Not serious
Action taken: Door repaired. Staff will
Corrected on site
34c - DOOR/GATE
The gate to the pool enclosure nearest the whirlpool timer is not self-closing and self-latching.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Action taken:
-
Aug 10, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: san recommended to provide
11b - CHEMICAL - STORAGE
Chemicals are improperly stored in pump room in accordance with ATCP 76.12(2). Chlorine stored next to acid.
Correction: Store chemicals in accordance with ATCP 76.12(2). If unable to store in separate locations, then provide spill protection.
Code ATCP 76.12(2)
-
Not serious
Action taken: Diane will test whirlpool
Corrected on site
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for pH and free chlorine is not in compliance with ATCP 76.18(3), due to ORP reading of 862mV during the inspection.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: Until it can be properly m
26h - RESCUE EQUIPMENT - ACCESSIBLE
Shepherd's crook is on site but not readily accessible - stored on ground between the whirlpool and the glass barrier. Also, the pole is too long for practical use at this whirlpool.
Correction: Mount the shepherd's crook in a readily accessible location. Provide a shorter pole that is easier to use in the event of an emergency.
Code ATCP 76.26(1)(a)
-
Not serious
Action taken: san recommended to provide
-
Jun 28, 2021 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.