Aug 29, 2025 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP (Pf) - Not Corrected
The water potential was 949 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING (Ppf) - Not Corrected
A pool basin in the facility does not have a 'Warning: No Lifeguard on Duty' sign that is in 4 inch lettering.
Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.23(2)
-
Not serious
Action taken:
-
Aug 18, 2025 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP (Pf)
The water potential was 949 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING (Ppf)
A pool basin in the facility does not have a 'Warning: No Lifeguard on Duty' sign that is in 4 inch lettering.
Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.23(2)
-
Not serious
Action taken: Pool was closed. Contact S
26n - TELEPHONE - NOT WORKING (P)
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
-
Jul 14, 2023 Pre-Inspection · No Reinspection Required
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 350ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS
The two exterior hose bibbs by the pool deck area not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken: Emergency phone is activat
26o - EMERGENCY NUMBERS AND ADDRESS
The non-emergency numbers are not posted near the designated emergency phone. There are no instructions posted for operating the emergency phone.
Correction: Post the non-emergency numbers and emergency phone operating instructions near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken: