The West Edge
1312 JOHN Q HAMMONS DR, Middleton, WI 53562 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2023-00402
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 6 | 0 |
| 2025 | 1 | 0 | 0 |
| 2024 | 1 | 4 | 0 |
| 2023 | 1 | 2 | 0 |
Inspections
-
May 18, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Door to chemical storage area is not marked to indicate entry is for authorized personnel only.
Correction: Mark doors to chemical storage area for authorized personnel only.
Code ATCP 76.12(2)
-
Not serious
Action taken: Training course recommenda
11e - SDS AVAILABILITY (Pf)
Staff are not trained on the use of safety data sheets.
Correction: Train staff on the use of safety data sheets.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Interlock video provided w
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: Template provided.
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING (Ppf)
Provided "Warning: No Lifeguard on Duty Sign" lettering is less than 4 inches.
Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.23(2)
-
Not serious
Action taken: Carbon monoxide alarm inst
Corrected on site
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken:
-
May 22, 2025 Routine Inspection · No Reinspection Required
No violations cited.
-
May 16, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) or screen for the skimmers is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
06b - STRAINER BASKET CLEANED
Strainer baskets or screens are not cleaned regularly. Pump strainer basket not cleaned since last pool season.
Correction: Clean strainer baskets and screens daily to prevent the accumulation of debris.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 609mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV. Test pH and chlorine residual twice a day until controller is properly functioning.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
-
Jun 26, 2023 Pre-Inspection · No Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 620 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency number(s) is not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken:
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.