Waterside Apartments
9201 WATERSIDE ST, Middleton, WI 53562 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 61653-59153
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 0 |
| 2025 | 2 | 6 | 0 |
| 2023 | 3 | 13 | 0 |
| 2021 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 2 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 22, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Ratio adjusted during insp
Corrected on site
05a - SKIMMER/MAIN DRAIN RATIO (Pf)
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket for the recirculation pump is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
22a - THERMOMETER (Pf)
There is no functional or visible thermometer installed on the pool water return line.
Correction: Install a working thermometer on the pool water return line.
Code ATCP 76.19(4)(a)
-
Not serious
Action taken:
25n - LIFEGUARD - SIGNAGE (Ppf)
The posted no lifeguard sign lettering is less than 4 inches.
Correction: Post an approved sign with letters at least 4 inches high stating: "Warning: No Lifeguard on Duty."
Code ATCP 76.23(2)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf)
Items are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken: 2 emergency blankets provi
Corrected on site
26s - BLANKETS MISSING (Pf)
2 conventional or emergency blankets are not available in the pool area.
Correction: Provide 2 conventional or emergency blankets in the pool area.
Code ATCP 76.27(1)(3)
-
Not serious
Action taken:
28f - FILES MAINTAINED
A current pool code is not permanently maintained on the premise.
Correction: Provide all files pursuant to ATCP 76.32(3).
Code ATCP 76.32(3)
-
Not serious
Action taken: Ratio adjusted during insp
Corrected on site
-
Jul 11, 2025 Re-Inspection · No Reinspection Required
No violations cited.
-
Jun 30, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Factsheet and application
02b - VARIANCE (P)
The operator is not complying with the condition's of an approved variance. Facility uses a push button emergency phone.
Correction: Comply with the approved variance and maintain a copy of the approved variance at the pool.
Code ATCP 76.02(2)(b)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Doors to the pump room where chemicals are stored are not marked to indicate entry is for authorized personnel only.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
22a - THERMOMETER (Pf)
There is no functional or visible thermometer installed on the pool water return line.
Correction: Install a working thermometer on the pool water return line.
Code ATCP 76.19(4)(a)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING (Pf)
'NO DIVING' is not posted in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken:
28f - FILES MAINTAINED
Pump curve, filter manual of instruction, and most current ATCP 76 are not permanently maintained on the premise.
Correction: Provide all files pursuant to ATCP 76.32(3).
Code ATCP 76.32(3)
-
Not serious
Action taken: Factsheet and application
-
Jul 26, 2023 Re-Inspection · No Reinspection Required
No violations cited.
-
Jul 25, 2023 Re-Inspection · Reinspection Required
No violations cited.
-
Jul 17, 2023 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Thiosulfate added during i
Corrected on site
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
16b - CYANURIC ACID
The cyanuric acid concentration is 80ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for [chemical] is not in compliance with ATCP 76.18(3). Cyanuric acid is not tested weekly.
Correction: Perform water testing in accordance with ATCP 76.18(3). Test cyanuric acid 1/week.
Code ATCP 76.18(3)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS
The hose bibb by the water fountain is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING
A pool basin in the facility does not have a 'No Lifeguard on Duty' sign.
Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.22(1)(c); ATCP 76.23(2)
-
Not serious
Action taken:
26f - PATRON LOAD - NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken:
26p - FIRST AID KIT - AVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken:
Corrected on site
27a - RULES NOT ENFORCED
The following posted rule is not being enforced: Patron in pool enclosure drinking beverage.
Correction: Enforce the posted pool rules.
Code ATCP 76.29(1)(a)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING
'NO DIVING' is not posted in the pool rules.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 16, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 26, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 17, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 3, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 28, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 12, 2014 Reinspection · No Reinspection Required
No violations cited.
-
Jul 28, 2014 Routine Inspection · Reinspection Required
No violations cited.
-
Jul 23, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 11, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.