RecordWell Data

Waterside Apartments

9201 WATERSIDE ST, Middleton, WI 53562 · Dane County

26cited violations
0serious tier
15inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
61653-59153
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026170
2025260
20233130
2021100
2018100
2017100
2016100
2015100
2014200
2013100
2012100

Inspections

  1. Jul 22, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Ratio adjusted during insp Corrected on site

      05a - SKIMMER/MAIN DRAIN RATIO (Pf)

      The skimmer to main drain flow ratio is not set correctly.

      Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket for the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      22a - THERMOMETER (Pf)

      There is no functional or visible thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Action taken:

      25n - LIFEGUARD - SIGNAGE (Ppf)

      The posted no lifeguard sign lettering is less than 4 inches.

      Correction: Post an approved sign with letters at least 4 inches high stating: "Warning: No Lifeguard on Duty."

      Code ATCP 76.23(2)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: 2 emergency blankets provi Corrected on site

      26s - BLANKETS MISSING (Pf)

      2 conventional or emergency blankets are not available in the pool area.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      28f - FILES MAINTAINED

      A current pool code is not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3).

      Code ATCP 76.32(3)

  2. Jul 11, 2025 Re-Inspection · No Reinspection Required

    No violations cited.

  3. Jun 30, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Factsheet and application

      02b - VARIANCE (P)

      The operator is not complying with the condition's of an approved variance. Facility uses a push button emergency phone.

      Correction: Comply with the approved variance and maintain a copy of the approved variance at the pool.

      Code ATCP 76.02(2)(b)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Doors to the pump room where chemicals are stored are not marked to indicate entry is for authorized personnel only.

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      22a - THERMOMETER (Pf)

      There is no functional or visible thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' is not posted in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      28f - FILES MAINTAINED

      Pump curve, filter manual of instruction, and most current ATCP 76 are not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3).

      Code ATCP 76.32(3)

  4. Jul 26, 2023 Re-Inspection · No Reinspection Required

    No violations cited.

  5. Jul 25, 2023 Re-Inspection · Reinspection Required

    No violations cited.

  6. Jul 17, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken: Thiosulfate added during i Corrected on site

      14c - CHLORINE TOO HIGH

      The chlorine residual exceeded 10 ppm.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 80ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for [chemical] is not in compliance with ATCP 76.18(3). Cyanuric acid is not tested weekly.

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test cyanuric acid 1/week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The hose bibb by the water fountain is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      A pool basin in the facility does not have a 'No Lifeguard on Duty' sign.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken:

      26f - PATRON LOAD - NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      26p - FIRST AID KIT - AVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken: Corrected on site

      27a - RULES NOT ENFORCED

      The following posted rule is not being enforced: Patron in pool enclosure drinking beverage.

      Correction: Enforce the posted pool rules.

      Code ATCP 76.29(1)(a)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING

      'NO DIVING' is not posted in the pool rules.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(c)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  7. Jun 16, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jul 26, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Aug 17, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Aug 3, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jul 28, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Aug 12, 2014 Reinspection · No Reinspection Required

    No violations cited.

  13. Jul 28, 2014 Routine Inspection · Reinspection Required

    No violations cited.

  14. Jul 23, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  15. Jul 11, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.