Wyndham Garden Hotel
2969 CAHILL MAIN, Fitchburg, WI 53711 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 73445-81679
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 4 | 0 |
| 2025 | 1 | 5 | 0 |
| 2024 | 1 | 1 | 0 |
| 2021 | 1 | 4 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2013 | 2 | 0 | 0 |
Inspections
-
Feb 19, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is stuck and is not functioning properly.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken: Operator instructed to tes
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3), and there are no records of it being tested for.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: Operator replaced pool pho
Corrected on site
26n - TELEPHONE - NOT WORKING (P)
The emergency telephone does not work. There is a dial tone, but nothing happens when the phone is picked up and buttons are pressed.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
-
May 21, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket for the pool and whirlpool skimmers is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE (Pf)
Test kit reagents are being used past their expiration date, including 00871 reagent expired 2/24 and pH reagent expired 5/24.
Correction: Store reagents properly, in original containers, replace when expired.
Code ATCP 76.17(2)
-
Not serious
Action taken:
26s - BLANKETS MISSING (Pf)
2 conventional or emergency blankets are not available in the pool area.
Correction: Provide 2 conventional or emergency blankets in the pool area.
Code ATCP 76.27(1)(3)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Jan 11, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Provide CPO Certificate by
23b - NO CPO
The facility is not staffed with a current certified water attraction operator.
Correction: Acquire or train a certified water attraction operator for the facility.
Code ATCP 76.20(2)(a)
-
Not serious
Action taken: Provide CPO Certificate by
-
Dec 22, 2021 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional, float is stuck
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
20a - TEST KIT NOT APPROVED
The test kit used by the facility is expired.
Correction: Replace the test kit with one from the approved list.
Code ATCP 76.17(1)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency is not being done daily. Alkalinity is not being tested.
Correction: Perform water testing in accordance with ATCP 76.18(1). Test and record pH and free chlorine at least 1x/day, combined chlorine at least 2x/week and alkalinity at least 1x/week.
Code ATCP 76.18(1)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 28, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jan 25, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
May 22, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 16, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
May 5, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Nov 7, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jan 16, 2013 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.