RecordWell Data

Yahara Landing Apartments

1624 FORDEM AVE, Madison, WI 53704 · Dane County

19cited violations
0serious tier
14inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
22063-5658
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026270
2024130
2023290
2019100
2018100
2016200
2015100
2014100
2013200
2012100

Inspections

  1. Aug 26, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Aug 18, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken: Pool closed

      26n - TELEPHONE - NOT WORKING (P)

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Jun 6, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for cyanuric acid is not in compliance with ATCP 76.18(1). Testing of cyanuric acid must be done on a weekly basis.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for pH is not in compliance with ATCP 76.18(3). Because there is no electronic monitoring device, pH must be tested twice daily.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: Operator printed the neces Corrected on site

      28d - MONTHLY REPORTS AVAILABLE

      D-I-I and Fecal Contamination documents are not available for review.

      Correction: Keep records available for review.

      Code ATCP 76.32(3)

  4. Jul 13, 2023 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY - Not Corrected

      The total alkalinity is 270 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

  5. Jun 12, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      16a - pH

      The pH is 8.0.

      Correction: Maintain the pH between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Action taken: Repeat

      16b - CYANURIC ACID

      The cyanuric acid concentration is above 30 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 270 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken:

      26f - PATRON LOAD - NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately. The pool must be closed until the phone is working and a re-inspection is completed.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      Several items in the first aid kit are damaged and need to be replaced.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit. Keep in good condition and replace as needed.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      28d - MONTHLY REPORTS AVAILABLE

      Water chemistry log is not being kept.

      Correction: Keep records available for review.

      Code ATCP 76.32(3)

    • Not serious Other

      41a - MISCELLANEOUS

      No record of when main drain grate or equalizer covers have been replaced or if they are still within manufacturer's lifespan

      Correction: Provide evidence that main drain grate and equalizer covers have not expired or have been replaced for meeting VBGA requirements. Please send inspector relevant paperwork within 30 days to avoid an additional re-inspection.

  6. Aug 27, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jun 26, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Sep 2, 2016 Reinspection · No Reinspection Required

    No violations cited.

  9. Aug 24, 2016 Routine Inspection · Reinspection Required

    No violations cited.

  10. Aug 5, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Aug 6, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Aug 29, 2013 Reinspection · Reinspection Required

    No violations cited.

  13. Aug 15, 2013 Routine Inspection · Reinspection Required

    No violations cited.

  14. Aug 21, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.