Yugo Madison Lux
433 W Johnson ST, Madison, WI 53703 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2023-00752
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 10 | 0 |
| 2025 | 2 | 19 | 0 |
| 2024 | 1 | 1 | 0 |
Inspections
-
Jul 15, 2026 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Template provided with ema
16d - COMBINED CHLORINE (Pf) - Not Corrected
The operator does not have a combined chlorine plan or is not following combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf) - Not Corrected
The water testing frequency for pH and chlorine residual is not in compliance with ATCP 76.18(3). pH and chlorine residual is not tested daily on weekends.
Correction: Perform water testing in accordance with ATCP 76.18(3). Test daily pH and chlorine residual every day the pool is open.
Code ATCP 76.18(3)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS (P) - Not Corrected
The hose bibb in the utility room is not protected against back siphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
29a - BASIN CLEANING - Not Corrected
In wall ladder stairs are discolored and in need of cleaning.
Correction: Keep the basin in a clean and sanitary condition pursuant to ATCP 76.33(1)(a).
Code ATCP 76.33(1)(a)
-
Not serious
Action taken: Template provided with ema
-
Jul 15, 2026 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
14a - CHLORINE TOO LOW (P)
The chlorine residual was 0.6ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to 1.0ppm. Call inspector to schedule a reopening inspection.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken:
16a - pH (P)
The pH is 7.0.
Correction: Close pool and raise the pH between 7.2 and 7.8. Call inspector to schedule a reopening inspection.
Code ATCP 76.14(5)(c)
-
Not serious
Action taken: Template provided with ema
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan or is not following combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for pH and chlorine residual is not in compliance with ATCP 76.18(3). pH and chlorine residual is not tested daily on weekends.
Correction: Perform water testing in accordance with ATCP 76.18(3). Test daily pH and chlorine residual every day the pool is open.
Code ATCP 76.18(3)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS (P)
The hose bibb in the utility room is not protected against back siphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
29a - BASIN CLEANING
In wall ladder stairs are discolored and in need of cleaning.
Correction: Keep the basin in a clean and sanitary condition pursuant to ATCP 76.33(1)(a).
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
-
Aug 15, 2025 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: 8/13: Manager contacted co
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected
Operator cannot demonstrate knowledge of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: 8/13 Manager scheduled tra
14e - WATER POTENTIAL ORP (Pf) - Not Corrected
The alarm indicator on the unit was blinking and there is no ORP display.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: 8/15 pool was partially dr
16b - CYANURIC ACID (Pf) - Not Corrected
The cyanuric acid concentration is 45ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken: 8/13: Manager contacted co
-
Aug 13, 2025 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf)
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Manager contacted contract
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: Manager scheduled training
14e - WATER POTENTIAL ORP (Pf)
The water potential was 413mV at the time of the inspection. The alarm indicator on the unit was blinking.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
16b - CYANURIC ACID (Pf)
The cyanuric acid concentration is 100ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken: Sanitarian to provide CC p
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken: Manager tasked maintenance
20b - TEST KIT REAGENT STORAGE (Pf)
Many of the test kit reagents available in the pump room are past their expiration date.
Correction: Store reagents properly, in original containers, replace when expired.
Code ATCP 76.17(2)
-
Not serious
Action taken: Manager immediately contac
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency is not in compliance with ATCP 76.18(3). Manager informed that pool is tested weekly by a contracted company and there is no daily onsite testing.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: Manager scheduled training
23a - OPERATOR REQUIREMENT (Ppf)
No operator is available for the pool for daily maintenance and water testing and ensuring that the equipment is properly functioning. Manager informed that a CPO is contracted to provide weekly testing and maintenance.
Correction: Acquire or train an operator knowledgeable on pool operation and maintenance.
Code ATCP 76.20(1)
-
Not serious
Action taken: Apply for a variance.
26m - TELEPHONE - NO CONNECTION TO EMERGENCY SERVICES (P)
The push button phone does not directly connect to emergency services. When tested the connection is clear and the dispatch center informed that they are staffed 24/7 and in the event of an emergency would connect to 911.
Correction: Provide a telephone capable of connecting with emergency services at all times during pool operation or apply for a variance.
Code ATCP 76.26(2)(a)
-
Not serious
Action taken: A sign was found in the pu
26p - EMERGENCY NUMBERS AND ADDRESS (Pf)
The emergency numbers (of the responsible supervisor) and the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near or attached to the designated emergency phone.
Code ATCP 76.26(2)(d)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf)
Several items are missing from the first aid kit. PIC informed that some items are available onsite and can be relocated to the pool area.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken: Post sign available in pum
27b - SIGNAGE - SUPERVISION OF CHILDREN
Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage. There is a sign available in the pump room with this information.
Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b).
Code ATCP 76.29(1)(c)
-
Not serious
Any of the following conditions or situa
28a - CLOSING CRITERIA (P)
The pool was not closed by the operator or responsible supervisor under the following condition: see (f) and (i) below.
Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.
Code ATCP 76.30
-
Not serious
Action taken:
28e -REPORTS AND RECORDS (Pf)
No records are available for review onsite.
Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall
Code ATCP 76.32(1)
-
Not serious
Action taken: Maintenance worked to adju
34d - DOOR/GATE (P)
The gate to the pool enclosure is not self-latching. The door to the rooftop area is also not consistently self-latching, stopping just short of the latching mechanism.
Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.
Code ATCP 76.34(4)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drains and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
May 13, 2024 Pre-Inspection · No Reinspection Required
-
Not serious
Action taken:
29d - DECK DISINFECTION
Deck pavers are loose or missing. Operator stated deck is being evaluated for leaks.
Correction: Secure pavers before opening pool to patrons. Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.