The Lafayette
5123 CENTRAL PARK PL, Fitchburg, WI 53711 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2020-00136
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 16 | 0 |
| 2025 | 1 | 0 | 0 |
| 2022 | 2 | 13 | 0 |
| 2021 | 1 | 0 | 0 |
Inspections
-
Jul 1, 2026 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
05b - WATER LEVEL (Pf) - Not Corrected
The whirlpool water level is not adequate for continuous effective surface skimming, as the level is too high.
Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continuous water supply over the gutter.
Code ATCP 76.11(2)(a) and ATCP 76.19(3)
-
Not serious
Action taken:
16c - ALKALINITY (Pf) - Not Corrected
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken: Operator provided with Com
16d - COMBINED CHLORINE (Pf) - Not Corrected
The operator does not have a combined chlorine plan or is not following combined chlorine plan, as combined chlorine levels tested at 0.8 at time of inspection.
Correction: Provide and/or implement a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken: Chargeable reinspection re
Repeat
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf) - Not Corrected
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: In order to avoid a subseq
23c - NO CPO CERTIFICATE (Ppf) - Not Corrected
The facility is staffed with a current certified pool operator but the documentation is not available onsite.
Correction: Provide documentation of the certified pool operator for the facility.
Code ATCP 76.20(2)(c)
-
Not serious
Action taken: Operator attached rope to
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P) - Not Corrected
Whirlpool ring buoy is on site but is missing the rope.
Correction: Mount properly sized ring buoy, position in a conspicuous place that is readily accessible, and maintain in good repair with rope securely attached.
Code ATCP 76.26(1)
-
Not serious
Action taken: Operator fixed door.
Corrected on site
34d - DOOR/GATE (P) - Not Corrected
The door to the whirlpool enclosure is not latching.
Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.
Code ATCP 76.34(4)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Jun 9, 2026 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
05b - WATER LEVEL (Pf)
The whirlpool water level is not adequate for continuous effective surface skimming, as the level is too high.
Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continuous water supply over the gutter.
Code ATCP 76.11(2)(a) and ATCP 76.19(3)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken: Operator provided with Com
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan or is not following combined chlorine plan, as combined chlorine levels tested at 0.8 at time of inspection.
Correction: Provide and/or implement a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken: Chargeable reinspection re
Repeat
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: In order to avoid a subseq
23c - NO CPO CERTIFICATE (Ppf)
The facility is staffed with a current certified pool operator but the documentation is not available onsite.
Correction: Provide documentation of the certified pool operator for the facility.
Code ATCP 76.20(2)(c)
-
Not serious
Action taken: Operator attached rope to
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)
Whirlpool ring buoy is on site but is missing the rope.
Correction: Mount properly sized ring buoy, position in a conspicuous place that is readily accessible, and maintain in good repair with rope securely attached.
Code ATCP 76.26(1)
-
Not serious
Action taken: Operator fixed door.
Corrected on site
34d - DOOR/GATE (P)
The door to the whirlpool enclosure is not latching.
Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.
Code ATCP 76.34(4)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Jun 4, 2025 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 20, 2022 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: PIC contacted pool company
14e - WATER POTENTIAL ORP - Not Corrected
ORP is turned "off" on monitoring device in pump room.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE - Not Corrected
The water testing frequency is not in compliance with ATCP 76.18(2). The pool does not have ORP monitoring.
Correction: Perform water testing in accordance with ATCP 76.18(2).
Code ATCP 76.18(2)
-
Not serious
Action taken:
30b - SHOWERS - Not Corrected
The floor in the shower area is cracked.
Correction: Repair the showers.
Code ATCP 76.33(2)(b)
-
Not serious
Action taken: PIC contacted pool company
-
Jul 19, 2022 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional. The bobber is stuck.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken: PIC plans to drain pool.
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm. Chlorine level is 13.4 ppm.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
ORP is turned "off" on monitoring device in pump room.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 30ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken: PIC plans to drain whirlpo
16d - COMBINED CHLORINE
The combined chlorine is 1.2ppm.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE
The test kit reagents are empty and or expired.
Correction: Keep reagents in original containers.
Code ATCP 76.17(2)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency is not in compliance with ATCP 76.18(2). The pool does not have ORP monitoring.
Correction: Perform water testing in accordance with ATCP 76.18(2).
Code ATCP 76.18(2)
-
Not serious
Action taken: PIC provided a secure Shep
Corrected on site
26i - RESCUE EQUIPMENT - MISSING
The Shepherd's Crook was detached from the rod. The rod was broken.
Correction: Provide a Shepherd's Crook for the whirlpool and mount it in a conspicuous location.
Code ATCP 76.26(1)(b)
-
Not serious
Action taken:
30b - SHOWERS
The floor in the shower area is cracked.
Correction: Repair the showers.
Code ATCP 76.33(2)(b)
-
Not serious
Action taken: PIC repaired the door to b
Corrected on site
34c - DOOR/GATE
The door or gate to the pool enclosure is not self-latching.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Action taken:
-
Sep 29, 2021 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.