RecordWell Data

The Lafayette

5123 CENTRAL PARK PL, Fitchburg, WI 53711 · Dane County

29cited violations
0serious tier
6inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2020-00136
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262160
2025100
20222130
2021100

Inspections

  1. Jul 1, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      05b - WATER LEVEL (Pf) - Not Corrected

      The whirlpool water level is not adequate for continuous effective surface skimming, as the level is too high.

      Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continuous water supply over the gutter.

      Code ATCP 76.11(2)(a) and ATCP 76.19(3)

    • Not serious Action taken:

      16c - ALKALINITY (Pf) - Not Corrected

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Operator provided with Com

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan or is not following combined chlorine plan, as combined chlorine levels tested at 0.8 at time of inspection.

      Correction: Provide and/or implement a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Chargeable reinspection re Repeat

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf) - Not Corrected

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: In order to avoid a subseq

      23c - NO CPO CERTIFICATE (Ppf) - Not Corrected

      The facility is staffed with a current certified pool operator but the documentation is not available onsite.

      Correction: Provide documentation of the certified pool operator for the facility.

      Code ATCP 76.20(2)(c)

    • Not serious Action taken: Operator attached rope to Corrected on site

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P) - Not Corrected

      Whirlpool ring buoy is on site but is missing the rope.

      Correction: Mount properly sized ring buoy, position in a conspicuous place that is readily accessible, and maintain in good repair with rope securely attached.

      Code ATCP 76.26(1)

    • Not serious Action taken: Operator fixed door. Corrected on site

      34d - DOOR/GATE (P) - Not Corrected

      The door to the whirlpool enclosure is not latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Jun 9, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      05b - WATER LEVEL (Pf)

      The whirlpool water level is not adequate for continuous effective surface skimming, as the level is too high.

      Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continuous water supply over the gutter.

      Code ATCP 76.11(2)(a) and ATCP 76.19(3)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Operator provided with Com

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan, as combined chlorine levels tested at 0.8 at time of inspection.

      Correction: Provide and/or implement a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Chargeable reinspection re Repeat

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: In order to avoid a subseq

      23c - NO CPO CERTIFICATE (Ppf)

      The facility is staffed with a current certified pool operator but the documentation is not available onsite.

      Correction: Provide documentation of the certified pool operator for the facility.

      Code ATCP 76.20(2)(c)

    • Not serious Action taken: Operator attached rope to Corrected on site

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)

      Whirlpool ring buoy is on site but is missing the rope.

      Correction: Mount properly sized ring buoy, position in a conspicuous place that is readily accessible, and maintain in good repair with rope securely attached.

      Code ATCP 76.26(1)

    • Not serious Action taken: Operator fixed door. Corrected on site

      34d - DOOR/GATE (P)

      The door to the whirlpool enclosure is not latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Jun 4, 2025 Routine Inspection · No Reinspection Required

    No violations cited.

  4. Jul 20, 2022 Re-Inspection · No Reinspection Required
    • Not serious Action taken: PIC contacted pool company

      14e - WATER POTENTIAL ORP - Not Corrected

      ORP is turned "off" on monitoring device in pump room.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE - Not Corrected

      The water testing frequency is not in compliance with ATCP 76.18(2). The pool does not have ORP monitoring.

      Correction: Perform water testing in accordance with ATCP 76.18(2).

      Code ATCP 76.18(2)

    • Not serious Action taken:

      30b - SHOWERS - Not Corrected

      The floor in the shower area is cracked.

      Correction: Repair the showers.

      Code ATCP 76.33(2)(b)

  5. Jul 19, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional. The bobber is stuck.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: PIC plans to drain pool.

      14c - CHLORINE TOO HIGH

      The chlorine residual exceeded 10 ppm. Chlorine level is 13.4 ppm.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      ORP is turned "off" on monitoring device in pump room.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 30ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken: PIC plans to drain whirlpo

      16d - COMBINED CHLORINE

      The combined chlorine is 1.2ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      The test kit reagents are empty and or expired.

      Correction: Keep reagents in original containers.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE

      The water testing frequency is not in compliance with ATCP 76.18(2). The pool does not have ORP monitoring.

      Correction: Perform water testing in accordance with ATCP 76.18(2).

      Code ATCP 76.18(2)

    • Not serious Action taken: PIC provided a secure Shep Corrected on site

      26i - RESCUE EQUIPMENT - MISSING

      The Shepherd's Crook was detached from the rod. The rod was broken.

      Correction: Provide a Shepherd's Crook for the whirlpool and mount it in a conspicuous location.

      Code ATCP 76.26(1)(b)

    • Not serious Action taken:

      30b - SHOWERS

      The floor in the shower area is cracked.

      Correction: Repair the showers.

      Code ATCP 76.33(2)(b)

    • Not serious Action taken: PIC repaired the door to b Corrected on site

      34c - DOOR/GATE

      The door or gate to the pool enclosure is not self-latching.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

  6. Sep 29, 2021 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.