RecordWell Data

The New Fountains

5401 WILLIAMSBURG WAY, Fitchburg, WI 53719 · Dane County

26cited violations
0serious tier
10inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2017-00281
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025130
2024190
20232140
2021100
2019100
2018100
2017300

Inspections

  1. Jul 10, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Be sure to work with pool

      08a - RECIRCULATION RATE - SWIM/COMBO (Pf)

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours. Turnover rate calculated to be 7.14 at time of inspection.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken: Operator attached rope. Corrected on site

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)

      Ring buoy is on site, but rope not attached.

      Correction: Mount properly sized ring buoy, position in a consipicuous place that is readily accessible, and maintain in good repair with rope attached.

      Code ATCP 76.26(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      ORP pH sensor is not properly maintained and calibrated as necessary, as the ORP readout is 8.4 for pH and it tested at 7.4 during inspection.

      Correction: Properly locate, intall, maintain and repair equipment.

      Code ATCP 76.33(1)(e)

  2. Jul 31, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket is not available.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken: PIC adjusted pH, at end of Corrected on site

      16a - pH

      The pH is 7.0 and yellow.

      Correction: Adjust to pH between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Action taken: Adjust alkalinity.

      16c - ALKALINITY

      The total alkalinity is 30.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken: Discussed ordering new rea

      20b - TEST KIT REAGENT STORAGE

      Chlorine testing reagent is expired.

      Correction: Keep reagents in original containers.

      Code ATCP 76.17(2)

    • Not serious Action taken: Discussed testing weekly.

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for alkalinity is not in compliance with ATCP 76.18(3). Alkalinity has not been consistently tested weekly.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA

      According to the pool logs for this summer, there are many days in which the chlorine levels are documented as less than 1ppm. PIC informed water is tested and documented in the morning and they are aiming for 1-3ppm of chlorine. Corrective action column does not indicate that chlorine was increased prior to opening pool for the day.

      Correction: Ensure that the closing criteria are adhered to under the listed below.

      Code ATCP 76.30

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Bobber on flow meter is stuck.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. If information is not found, make/model and date of manufacturer may be obtained directly from grate.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  3. Aug 30, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket for the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO - Not Corrected

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(a)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Aug 1, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket for the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(a)

    • Not serious Action taken: Pool closed.

      14a - CHLORINE TOO LOW

      The chlorine residual was 0.6 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken: Discussed testing requirem

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency is not in compliance with ATCP 76.18(3). Water is not tested regularly and pool testing logs are not available onsite.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      26i - RESCUE EQUIPMENT - MISSING

      A ring buoy is present but is missing a rope.

      Correction: Provide a rope for the ring buoy and mount it in a conspicuous location.

      Code ATCP 76.26(1)(b)

    • Not serious Action taken: Pool Closed.

      26m - TELEPHONE - NOT WORKING

      The emergency telephone connects to 911 however the connection has static and the communication is one-sided. Emergency responders cannot be heard.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken: Signage was stored in pump Corrected on site

      26o - EMERGENCY NUMBERS AND ADDRESS

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26p - FIRST AID KIT - AVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      29f - DEPTH MARKINGS VISIBLE

      The depth markings along the edge of the pool are fading and the paint is chipping.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jun 23, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jun 7, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Aug 23, 2018 Routine Inspection · Reinspection Required

    No violations cited.

  8. Aug 22, 2017 Re-Inspection · No Reinspection Required

    No violations cited.

  9. Aug 21, 2017 Routine Inspection · Reinspection Required

    No violations cited.

  10. Jun 2, 2017 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.