RecordWell Data

Iron Gate Apartments

2525 IRONWOOD DR, Sun Prairie, WI 53590 · Dane County

27cited violations
0serious tier
13inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWM-2012-00230
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026260
20252160
2023140
2022110
2021100
2018100
2017100
2015100
2014100
2013100
2012100

Inspections

  1. Jul 16, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: Pool closed during the ins Corrected on site

      14a - CHLORINE TOO LOW (P)

      The chlorine residual was 0.6 ppm (0.1 ppm - 1.1 ppm due to degree of error) at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to 1.5 ppm.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 250 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Instant cold packs are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The pool basin is showing some pitting on the bottom of the basin.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

  2. Jun 17, 2026 Re-Inspection · No Reinspection Required

    No violations cited.

  3. Aug 29, 2025 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf) - Not Corrected

      7/16/2025: The total alkalinity is 40 ppm. 8/29/2025 re-inspection: The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf) - Not Corrected

      The water testing frequency for total alkalinity, combined chlorine, and cyanuric acid (if using) are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine level at least 2 times per week. Test total alkalinity and cyanuric acid levels at least once weekly.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR - Not Corrected

      The pool basin is showing some pitting on the bottom of the basin.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      34d - DOOR/GATE (P) - Not Corrected

      The door or gate to the pool enclosure requires an electronic key fob to exit the pool enclosure.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  4. Jul 16, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Two skimmer weirs are broken.

      Correction: Replace broken weirs or install floating weir.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      11a - CHEMICAL - LABELING (Pf)E

      The chlorine tank is not labeled according to ATCP 76.12(1).

      Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number, if applicable.

      Code ATCP 76.12(1)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for total alkalinity, combined chlorine, and cyanuric acid (if using) are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine level at least 2 times per week. Test total alkalinity and cyanuric acid levels at least once weekly.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      The elastic bandage is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      26t - BIOHAZARD SAFETY KIT (Pf)

      No biohazard safety kit is located at the first aid station or on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The pool basin is showing some pitting on the bottom of the basin.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      34d - DOOR/GATE (P)

      The door or gate to the pool enclosure requires an electronic key fob to exit the pool enclosure.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  5. Aug 24, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 872 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1). The test is not being completed.

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test combined chlorine at least twice a week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      There are areas of concrete that are cracked and chipping away at the side of the pool edge.

      Correction: Repair the pool basin and deck so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Jul 27, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Backflow preventer install Corrected on site

      30i - HOSE BIBBS

      Hose bibb located at the far end away from the gate is not equipped with a backflow preventer. .

      Correction: Install a hose bibb in a location making it accessible to rinse and sanitize the floors. Install a backflow preventer on the hose bibb.

      Code ATCP 76.33(2)(i)

  7. Jun 16, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. May 31, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 19, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jul 22, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jul 16, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jul 22, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Aug 16, 2012 Pre-Inspection · Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.