The Sovereign Apartments
4829 SHEBOYGAN AVE, Madison, WI 53705 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 68676-72438
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 6 | 0 |
| 2025 | 1 | 4 | 0 |
| 2024 | 2 | 12 | 0 |
| 2022 | 2 | 26 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 3 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 2 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 23, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: sanitarian provided Jason
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill protection to prevent acid from mixing with liquid chlorine.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week and cyanuric acid 1x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS (P)
The hose bibb in the pump room is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
No biohazard safety kit is located at the first aid station or on the premises.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken: sanitarian provided Jason
-
Jul 22, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: sanitarian provided Jason
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill protection to prevent acid from mixing with liquid chlorine.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week and cyanuric acid 1x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
No biohazard safety kit is located at the first aid station or on the premises.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Action taken: sanitarian provided Jason
-
Jun 27, 2024 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER - Not Corrected
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Equalizer covers (2) missing at time of inspection. Main drain covers in place and appear in good condition.
Correction: Close pool until equalizer covers are replaced. Complete and maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 26, 2024 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Miguel added 6 oz of sodiu
Corrected on site
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm. Free chlorine measured at 10.4ppm.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken: fact sheet provided along
20c - WATER TESTING - POOLS
The water testing frequency for pH, free chlorine, combined chlorine, alkalinity, and cyanuric acid are not in compliance with ATCP 76.18(1). No pool testing records available at time of inspection.
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken: shepherd's crook replaced
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE
Shepherd's crook is on site but not readily accessible.
Correction: Mount shepherd's crook in a readily accessible location.
Code ATCP 76.26(1)(a)
-
Not serious
Action taken:
26n - TELEPHONE - LOCATION
The emergency telephone is not in the enclosure or accessible and there is no sign posted inside the pool enclosure indicating the exact location of the emergency phone.
Correction: Provide a sign within the pool enclosure to indicate the exact location of the emergency telephone. Provide an additional sign at the emergency phone to clearly indicate that this is the emergency telephone.
Code ATCP 76.26(2)
-
Not serious
Action taken: Miguel reposted signs for
Corrected on site
27d - SIGNAGE - NO DIVING
'NO DIVING' is not posted in the pool rules.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Any of the following conditions or situa
28a - CLOSING CRITERIA
The pool was not closed under the following conditions: 1)pool gate not self-closing and self-latching 2) 2 VGBA equalizer covers missing, and 3) free chlorine level was >10ppm.
Correction: Ensure that the closing criteria are adhered to under the listed below.
Code ATCP 76.30
-
Not serious
Action taken: Miguel began repairs durin
34c - DOOR/GATE
The door or gate to the pool enclosure is not self-closing, self-latching, and/or is not lockable. Gate mechanism not properly aligned and will not self-close or self-latch unless manually lifted into place.
Correction: Close pool until gate is repaired. Repair the gate entrance immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Equalizer covers (2) missing at time of inspection. Main drain covers in place and appear in good condition.
Correction: Close pool until equalizer covers are replaced. Complete and maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 12, 2022 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET - Not Corrected
A spare skimmer basket is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER - Not Corrected
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11e - SDS AVAILABILITY - Not Corrected
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - ORP - Not Corrected
The water testing frequency for pH, disinfectant, combined chlorine, alkalinity, and cyanuric acid is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING - Not Corrected
A pool basin in the facility does not have a 'No Lifeguard on Duty' sign.
Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.22(1)(c); ATCP 76.23(2)
-
Not serious
Action taken:
26n - TELEPHONE - LOCATION - Not Corrected
The emergency telephone is located outside the pool enclosure. No sign is posted inside the pool enclosure indicating exact location of emergency phone.
Correction: Provide a sign in the pool enclosure indicating the exact location of the emergency phone in lettering that is a minimum of 1 inch in height.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS - Not Corrected
The emergency numbers and/or the facility's location are not posted near the designated emergency phone.
Correction: In addition to emergency 911 number, post phone numbers of responsible supervisor for non-emergency pool concerns.
Code ATCP 76.26(2)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING - Not Corrected
'NO DIVING' is not posted in the pool rules.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Action taken:
29d - DECK DISINFECTION - Not Corrected
(1) The pool areas are not being cleaned and sanitized regularly. Leaves, twigs, or sediment accumulated in skimmer baskets, deck, and pool basin. (2) The pH indicated on the electronic monitor is 7.4 and significantly different than test kit reading of 8.0.
Correction: (1) Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(a). (2) Replace, repair, adjust or calibrate the pH senor or electronic monitor to effectively control automatic acid feeding.
Code ATCP 76.33(1)(a), (1)(e)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN - Not Corrected
The drinking fountain is located outside the pool enclosure without approved variance. No sign is posted in the pool enclosure that indicates the exact location of the drinking fountain.
Correction: Post a sign in the pool enclosure indicating the exact location of the drinking fountain in lettering that is a minimum of 1 inch in height.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
Corrected on site
33a - HAZARDOUS MATERIAL - Not Corrected
Pool water back feeding into acid container in pump room causing pooled acid on floor at the time of the inspection.
Correction: Feeder stopped and part replaced. Acid cleaned from pump room.
Code ATCP 76.34(1)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Operator stated main drain and equilizer covers have never been replaced.
Correction: Replace main drain covers and equilizers before start of next pool season. Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 10, 2022 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare skimmer basket is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
16a - pH
The pH is 8.0.
Correction: Close the pool. Adjust level between 7.2 and 7.8. Pool may not reopen until verified by reinspection.
Code ATCP 76.14(4)(c)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for pH, disinfectant, combined chlorine, alkalinity, and cyanuric acid is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING
A pool basin in the facility does not have a 'No Lifeguard on Duty' sign.
Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.22(1)(c); ATCP 76.23(2)
-
Not serious
Action taken:
26n - TELEPHONE - LOCATION
The emergency telephone is located outside the pool enclosure. No sign is posted inside the pool enclosure indicating exact location of emergency phone.
Correction: Provide a sign in the pool enclosure indicating the exact location of the emergency phone in lettering that is a minimum of 1 inch in height.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and/or the facility's location are not posted near the designated emergency phone.
Correction: In addition to emergency 911 number, post phone numbers of responsible supervisor for non-emergency pool concerns.
Code ATCP 76.26(2)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING
'NO DIVING' is not posted in the pool rules.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Any of the following conditions or situa
28a - CLOSING CRITERIA
The pool was not closed under the following condition: pH exceeding 8.0
Correction: Ensure that the closing criteria are adhered to under the listed below.
Code ATCP 76.30
-
Not serious
Action taken:
29d - DECK DISINFECTION
(1) The pool areas are not being cleaned and sanitized regularly. Leaves, twigs, or sediment accumulated in skimmer baskets, deck, and pool basin. (2) The pH indicated on the electronic monitor is 7.4 and significantly different than test kit reading of 8.0.
Correction: (1) Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(a). (2) Replace, repair, adjust or calibrate the pH senor or electronic monitor to effectively control automatic acid feeding.
Code ATCP 76.33(1)(a), (1)(e)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN
The drinking fountain is located outside the pool enclosure without approved variance. No sign is posted in the pool enclosure that indicates the exact location of the drinking fountain.
Correction: Post a sign in the pool enclosure indicating the exact location of the drinking fountain in lettering that is a minimum of 1 inch in height.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
Corrected on site
33a - HAZARDOUS MATERIAL
Pool water back feeding into acid container in pump room causing pooled acid on floor at the time of the inspection.
Correction: Feeder stopped and part replaced. Acid cleaned from pump room.
Code ATCP 76.34(1)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Operator stated main drain and equilizer covers have never been replaced.
Correction: Replace main drain covers and equilizers before start of next pool season. Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 30, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 3, 2019 Re-Inspection · No Reinspection Required
No violations cited.
-
Jul 1, 2019 Re-Inspection · Reinspection Required
No violations cited.
-
Jun 21, 2019 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 20, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 26, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
May 18, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 29, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 20, 2014 Reinspection · No Reinspection Required
No violations cited.
-
Jun 19, 2014 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 19, 2013 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 12, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.