Hotel Monona
722 John Nolen DR, Madison, WI 53713 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2022-00390
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 1 | 2 | 0 |
| 2024 | 1 | 5 | 0 |
| 2023 | 1 | 3 | 0 |
| 2022 | 1 | 6 | 0 |
Inspections
-
Mar 25, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) or screen for the skimmers and recirculation pump are not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken: Factsheet will be provided
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator is not testing chemical interlock system on a monthly basis per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
-
May 28, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Operator indicated flowmet
09a - FLOW METER
The flowmeter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 220ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken: Reagents discarded. Operat
20b - TEST KIT REAGENT STORAGE
The test kit reagents R-0007, R-0008, and R-0009 were expired. Test kit reagent R-0003 was missing.
Correction: Keep reagents in original containers.
Code ATCP 76.17(2)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
28d - MONTHLY REPORTS AVAILABLE
Monthly pool testing reports were not maintained for 2 years.
Correction: Keep records available for review.
Code ATCP 76.32(3)
-
Not serious
Action taken: Operator indicated flowmet
-
Feb 2, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
Spare strainer baskets for the skimmers area not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken: PIC removed misleading sig
Corrected on site
26m - TELEPHONE - NOT WORKING
The emergency telephone signage states that phone dials direct to 911. When tested, phone dials to front desk and is unable to make direct calls to 911.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken: Provide signage stating th
Corrected on site
26p - FIRST AID KIT - AVAILABLE
First aid kit is not available in the pool area. First aid kit is at front desk.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
-
Jun 3, 2022 Pre-Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket or for the recirculation pump is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken: PIC worked to replace and
Corrected on site
26m - TELEPHONE - NOT WORKING
The emergency telephone does not work. Initially there was no dial tone. Once dial tone was repaired, a second test was done, the phone called front desk and front desk did not answer (both phone lines occupied). Directions on phone indicate that 911 can be called directly, but dial pad does not work. Upon third test, front desk was on the other line and did not answer.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken: Provided list of required
26q - FIRST AID KIT - SUPPLIES MISSING
Several are missing from the first aid kit. First aid kit is located at front desk.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.
Code ATCP 76.27(1)
-
Not serious
Action taken: Signage provided to indica
Corrected on site
29g - DRINKING FOUNTAIN
The drinking fountain is not functional.
Correction: Repair/clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken: PIC adjusted door such tha
Corrected on site
34c - DOOR/GATE
The emergency exit door to the parking lot in the pool enclosure is not self-closing or self-latching.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: