RecordWell Data

Lesilve Apartment Homes

8560 GREENWAY BLVD, Middleton, WI 53562 · Dane County

31cited violations
0serious tier
13inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
73135-81321
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026180
20251100
2023160
2022170
2021100
2019100
2017100
2016100
2015100
2014100
2013200
2012100

Inspections

  1. Aug 17, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Adjusted during inspection Corrected on site

      05a - SKIMMER/MAIN DRAIN RATIO (Pf)

      The skimmer to main drain flow ratio is not set correctly.

      Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken: Repeat

      08a - RECIRCULATION RATE - SWIM/COMBO (Pf)

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Door to pool chemical storage area on first floor is not marked with authorized personnel only

      Correction: Mark chemical storage doors indicating entry is for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for cyanuric acid is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P)

      The hose bibb is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken: Provided with emailed repo

      28f - FILES MAINTAINED

      A copy of the current code is not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3).

      Code ATCP 76.32(3)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      Concrete is cracked and raised near pool stairs.

      Correction: Maintain deck in good repair.

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      Documentation available on site for VGBA main drain and/or equalizer covers does not include gallons per minute rating. No pump curve is available.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Sep 3, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO (Pf)

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Doors to chemical storage areas are unmarked.

      Correction: Doors to chemical storage areas shall be locked and marked to indicate entry is for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 210ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken: Template provided with ema

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2 times per week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P)

      The hose bibb is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      27b - SIGNAGE - SUPERVISION OF CHILDREN

      Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.

      Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b).

      Code ATCP 76.29(1)(c)

    • Not serious Action taken: Template provided with ema

      28e -REPORTS AND RECORDS (Pf)

      Operating report does not contain required documentation.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarm.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. Documentation of pump curve is not available.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Aug 10, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Repeat

      16b - CYANURIC ACID

      The cyanuric acid concentration is 100ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The pool hose bibb is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      (1) The pool basin is discolored around edge. (2) Tiles are missing along interior rim of pool basin. (3) Covers are missing at base of stair railings.

      Correction: Clean basin and maintain free of sediment, lint, debris, algae and slime growth, and discoloration. Repair missing tiles and replace cover and base of stair railings.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN

      The drinking fountain is not clean.

      Correction: Clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Pipe is leaking in pump room.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other Repeat

      34e - VGBA COVERS

      Equalizer covers are expired.

      Correction: Replace. Update and maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up. Submit receipt of replaced equalizer covers to sanitarian before compliance due date.

      Code ATCP 76.11(2)(b)

  4. Jul 26, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO

      The swimming pool or combination pool has a maximum turnover rate of 7.2 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(a)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 60 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      Some of the test kit reagents (DPD powder, phenol red, alkalinity reagents) are expired.

      Correction: Keep reagents in original containers and replace after expiration per manufacturer instructions.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The hose bibb of the outdoor hose for deck washing is missing a backflow preventer.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      Gauze roller bandage and 8x10 gauze pad are missing from the first aid kit. Eye wash is expired.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 28, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Aug 20, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jun 21, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 14, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 22, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  10. May 22, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jul 11, 2013 Reinspection · No Reinspection Required

    No violations cited.

  12. Jul 9, 2013 Routine Inspection · Reinspection Required

    No violations cited.

  13. Aug 2, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.