Lesilve Apartment Homes
8560 GREENWAY BLVD, Middleton, WI 53562 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 73135-81321
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 8 | 0 |
| 2025 | 1 | 10 | 0 |
| 2023 | 1 | 6 | 0 |
| 2022 | 1 | 7 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 2 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Aug 17, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Adjusted during inspection
Corrected on site
05a - SKIMMER/MAIN DRAIN RATIO (Pf)
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
Repeat
08a - RECIRCULATION RATE - SWIM/COMBO (Pf)
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(c)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Door to pool chemical storage area on first floor is not marked with authorized personnel only
Correction: Mark chemical storage doors indicating entry is for authorized personnel only.
Code ATCP 76.12(2)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for cyanuric acid is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS (P)
The hose bibb is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken: Provided with emailed repo
28f - FILES MAINTAINED
A copy of the current code is not permanently maintained on the premise.
Correction: Provide all files pursuant to ATCP 76.32(3).
Code ATCP 76.32(3)
-
Not serious
Action taken:
29d - DECK MAINTENANCE AND CLEANING (Pf)
Concrete is cracked and raised near pool stairs.
Correction: Maintain deck in good repair.
Code ATCP 76.33(1)(b)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
Documentation available on site for VGBA main drain and/or equalizer covers does not include gallons per minute rating. No pump curve is available.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken: Adjusted during inspection
Corrected on site
-
Sep 3, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
08a - RECIRCULATION RATE - SWIM/COMBO (Pf)
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(c)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Doors to chemical storage areas are unmarked.
Correction: Doors to chemical storage areas shall be locked and marked to indicate entry is for authorized personnel only.
Code ATCP 76.12(2)
-
Not serious
Action taken:
16b - CYANURIC ACID (Pf)
The cyanuric acid concentration is 210ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken: Template provided with ema
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2 times per week.
Code ATCP 76.18(3)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS (P)
The hose bibb is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
27b - SIGNAGE - SUPERVISION OF CHILDREN
Statement indicating that children under the age of 12 shall be supervised by an adult is missing from signage.
Correction: Add statement indicating that children under the age of 12 shall be supervised by an adult to the signage requirements in ATCP 76.29(1))(b).
Code ATCP 76.29(1)(c)
-
Not serious
Action taken: Template provided with ema
28e -REPORTS AND RECORDS (Pf)
Operating report does not contain required documentation.
Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall
Code ATCP 76.32(1)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarm.
Code ATCP 76.33(4)(d)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. Documentation of pump curve is not available.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Aug 10, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
Repeat
16b - CYANURIC ACID
The cyanuric acid concentration is 100ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS
The pool hose bibb is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
29b - BASIN DEFECTS
(1) The pool basin is discolored around edge. (2) Tiles are missing along interior rim of pool basin. (3) Covers are missing at base of stair railings.
Correction: Clean basin and maintain free of sediment, lint, debris, algae and slime growth, and discoloration. Repair missing tiles and replace cover and base of stair railings.
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN
The drinking fountain is not clean.
Correction: Clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
Pipe is leaking in pump room.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Other
Repeat
34e - VGBA COVERS
Equalizer covers are expired.
Correction: Replace. Update and maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up. Submit receipt of replaced equalizer covers to sanitarian before compliance due date.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
Repeat
-
Jul 26, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
08a - RECIRCULATION RATE - SWIM/COMBO
The swimming pool or combination pool has a maximum turnover rate of 7.2 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(a)
-
Not serious
Action taken:
16b - CYANURIC ACID
The cyanuric acid concentration is 60 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE
Some of the test kit reagents (DPD powder, phenol red, alkalinity reagents) are expired.
Correction: Keep reagents in original containers and replace after expiration per manufacturer instructions.
Code ATCP 76.17(2)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS
The hose bibb of the outdoor hose for deck washing is missing a backflow preventer.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Gauze roller bandage and 8x10 gauze pad are missing from the first aid kit. Eye wash is expired.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 28, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 20, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 21, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 14, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 22, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
May 22, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 11, 2013 Reinspection · No Reinspection Required
No violations cited.
-
Jul 9, 2013 Routine Inspection · Reinspection Required
No violations cited.
-
Aug 2, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.