Lesilve Apartment Homes

8560 GREENWAY BLVD, Middleton, WI 53562 · Dane County

10cited violations
0serious tier
14inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
73135-81322
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026270
2023130
2021100
2019200
2017200
2016100
2015100
2014100
2013200
2012100

Inspections

  1. Aug 17, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Adjusted during inspection Corrected on site

      05a - SKIMMER/MAIN DRAIN RATIO (Pf)

      The skimmer to main drain flow ratio is not set correctly.

      Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Doors to first floor chemical storage area are not marked indicating entry for authorized personnel only.

      Correction: Mark doors to chemical storage area indicating entry for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken: Adjusted to 7.4 during ins Corrected on site

      16a - pH (P)

      The pH is 7.0

      Correction: Maintain the pH between 7.2 and 7.8.

      Code ATCP 76.14(5)(c)

    • Not serious Action taken: Provided with emailed repo

      28f - FILES MAINTAINED

      A copy of the current pool code is not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3).

      Code ATCP 76.32(3)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      Documentation available on site for VGBA main drain and/or equalizer covers does not include gallons per minute rating. Pump curve for replaced recirculation pump is not available.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Provide pump curve for replaced recirculation pump.

      Code ATCP 76.38

  2. Mar 12, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 240ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING (Ppf)

      A pool basin in the facility does not have a 'Warning: No Lifeguard on Duty' sign.

      Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.23(2)

  3. Aug 10, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The whirlpool hose bibb is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      The whirlpool does not have a 'No Lifeguard on Duty' sign.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Other

      34e - VGBA COVERS

      One equalizer cover is expired and the other is missing.

      Correction: Replace expired cover. Obtain pool plans and determine whether current alteration is DSPS-approved and compliant for missing equalizer cover. Submit DSPS-approved plan or compliance statement to sanitarian. Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Jul 28, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  5. Aug 20, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jun 28, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jun 29, 2017 Re-Inspection · No Reinspection Required

    No violations cited.

  8. Jun 21, 2017 Routine Inspection · Reinspection Required

    No violations cited.

  9. Jun 14, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 22, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  11. May 22, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jul 11, 2013 Reinspection · No Reinspection Required

    No violations cited.

  13. Jul 9, 2013 Routine Inspection · Reinspection Required

    No violations cited.

  14. Aug 2, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.