Deer Creek Clubhouse

8561 GREENWAY BLVD, Middleton, WI 53562 · Dane County

33cited violations
0serious tier
16inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
73030-81195
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026180
20252130
2023190
2022230
2021100
2019100
2018100
2017100
2016100
2015200
2014100
2013100
2012100

Inspections

  1. Jul 9, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional .

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 230 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Template provided with ema Corrected on site

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for [chemical] is not in compliance with ATCP 76.18(1). Cyanuric acid is not tested once per week.

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test cyanuric acid once per week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P)

      The hose bibb by the emergency phone is not protected against back siphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf)

      2 conventional or emergency blankets are not available in the pool area.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' is not posted in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

    • Not serious Other Corrected on site

      34f - VGBA COVERS DOCUMENTATION (Pf)

      VGBA Drain and Equalizer Replacement log is missing gallons per minute rating . No pump curve documentation is available.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers and pump curve onsite and available for review during inspection. Log documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Sep 3, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf) - Not Corrected

      Doors to chemical storage areas are not lockable and unmarked.

      Correction: Doors to chemical storage areas shall be locked and marked to indicate entry is for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken: Template provided with ema

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf) - Not Corrected

      The water testing frequency for combined chlorine and cyanuric are not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2 times per week and cyanuric acid once per week.

      Code ATCP 76.18(3)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA (P) - Not Corrected

      The pool was not closed by the operator or responsible supervisor under the following condition: pH exceeds 8.0.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken: Template provided with ema

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      Operating report does not contain required documentation.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. Documentation of pump curve is not available.

      Correction: Provide documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain, equalizers, and pump curve on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Sep 3, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Doors to chemical storage areas are not lockable and unmarked.

      Correction: Doors to chemical storage areas shall be locked and marked to indicate entry is for authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken: Pool closed. Chemicals add

      16a - pH (P)

      The pH is greater than 8.0 and a significant magenta color.

      Correction: Maintain the pH between 7.2 and 7.8.

      Code ATCP 76.14(5)(c)

    • Not serious Action taken: Template provided with ema

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for combined chlorine and cyanuric are not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2 times per week and cyanuric acid once per week.

      Code ATCP 76.18(3)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA (P)

      The pool was not closed by the operator or responsible supervisor under the following condition: pH exceeds 8.0.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken: Template provided with ema

      28e -REPORTS AND RECORDS (Pf)

      Operating report does not contain required documentation.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date. Documentation of pump curve is not available.

      Correction: Provide documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain, equalizers, and pump curve on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  4. Aug 10, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Weir is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for combined chlorine and cyanuric acid are not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine 2/week and cyanuric acid 1/week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The hose bibb is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      (1) Tiles are missing along interior rim of pool basin. (2) Concrete is broken and loose by stairs.

      Correction: Repair the pool basin and deck so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a-b)

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN

      The drinking fountain is not functional.

      Correction: Repair the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      30e - SOAP

      The soap dispenser is empty.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      (1) Chemtrol monitor is timing out and feeder pumps are caked with chemical residue, rusty, and missing cover plates. (2) Stair hand rail is loose.

      Correction: Repair and maintain all equipment. Increase testing frequency for chlorine residual and pH to two times per day until Chemtrol monitor is properly functioning.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34e - VGBA COVERS

      Two equalizer covers are missing in the pool. Installed equalizer cover is expired.

      Correction: Install missing equalizer covers and replace expired equalizer cover. Update and maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 26, 2022 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      14e - WATER POTENTIAL ORP - Not Corrected

      The water potential was 622 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

  6. Jul 21, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 622 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: TDS recommend installing a

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

  7. Jul 21, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jul 25, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Aug 9, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jul 25, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jul 14, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Aug 3, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. May 20, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  14. May 27, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  15. May 27, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  16. Jun 4, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.