RecordWell Data

Super 8 Hotel

1602 W Beltline HWY 106, Madison, WI 53713 · Dane County

68cited violations
0serious tier
10inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2018-00757
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20263350
2025180
20233200
2022150
2020100
2018100

Inspections

  1. Jul 27, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Pool closed. A cease to op

      19b - WATER CLARITY (P) - Not Corrected

      The water quality of swimming pool has cloudiness. The water is not transparent.

      Correction: Close the pool immediately. Use fresh water and/or chemical clarifiers to improve clarity to an acceptable level.

      Code ATCP 76.16(2); 76.30(1)(b)

  2. Jun 4, 2026 Re-Inspection · Reinspection Required
    • Not serious Action taken: PIC cleaned both baskets. Corrected on site

      04b - SKIMMERS/GUTTERS CLEANED - Not Corrected

      Skimmer baskets are not clean.

      Correction: Maintain in a clean condition.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Discussed floating weir ba

      04c - SKIMMER BASKET/WEIR - Not Corrected

      Both weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: PIC printed DATCP's interl

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected

      Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: PIC printed DATCP's templa

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken: Tested with PIC and review Repeat Corrected on site

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf) - Not Corrected

      The water testing frequency is not in compliance with ATCP 76.18(3). No documentation reported in June. May pool records report values such as free chlorine 7.1, 7.3, 7.5ppm when 1 drop = 0.2ppm. Combined chlorine values such as 0.3ppm reported.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: PIC placed online order.

      26g - BREATH HOLDING PROHIBITION - SIGNAGE - Not Corrected

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Post address by phone in p

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf) - Not Corrected

      The facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near or attached to the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken: Move required items to poo

      26q - FIRST AID KIT - AVAILABLE (P) - Not Corrected

      A first aid kit is not available in the pool area. First aid kit available at front desk area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)(a)

    • Not serious Action taken: PIC ordered supplies durin

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected

      Instant cold pack and emergency blankets are missing from the first aid kit. Eye wash is expired.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: PIC placed order online fo

      26t - BIOHAZARD SAFETY KIT (Pf) - Not Corrected

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Any of the following conditions or situa

      28a - CLOSING CRITERIA (P) - Not Corrected

      The pool was not closed by the operator or responsible supervisor under the following condition: i, emergency doors not self-closing and self-latching.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken: Reviewed requirements for

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      On monthly pool logs, chemical testing is not at required frequency, monthly checks (pump safety, equipment safety) are not recorded, backwashing not indicated.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: PIC has plans to repair ri

      29g - DRINKING FOUNTAIN (P) - Not Corrected

      The drinking fountain on the right side is not functional. The drinking fountain on the left side provides water.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS - Not Corrected

      The pump room is not clean and sanitary, the floors have powdery residue, sand, debris, and trash.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken: CO detectors purchased and Corrected on site

      32d - CARBON MONOXIDE ALARMS (P) - Not Corrected

      There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken: The west door blocked by r Corrected on site

      34d - DOOR/GATE (P) - Not Corrected

      The emergency exit doors from the pool area to the outside are not self-closing or latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  3. Jun 3, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken: PIC cleaned both baskets. Corrected on site

      04b - SKIMMERS/GUTTERS CLEANED

      Skimmer baskets are not clean.

      Correction: Maintain in a clean condition.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Discussed floating weir ba

      04c - SKIMMER BASKET/WEIR

      Both weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: PIC printed DATCP's interl

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: PIC printed DATCP's templa

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken: Tested with PIC and review Repeat Corrected on site

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency is not in compliance with ATCP 76.18(3). No documentation reported in June. May pool records report values such as free chlorine 7.1, 7.3, 7.5ppm when 1 drop = 0.2ppm. Combined chlorine values such as 0.3ppm reported.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: PIC placed online order.

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Post address by phone in p

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf)

      The facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near or attached to the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken: Move required items to poo

      26q - FIRST AID KIT - AVAILABLE (P)

      A first aid kit is not available in the pool area. First aid kit available at front desk area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)(a)

    • Not serious Action taken: PIC ordered supplies durin

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Instant cold pack and emergency blankets are missing from the first aid kit. Eye wash is expired.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: PIC placed order online fo

      26t - BIOHAZARD SAFETY KIT (Pf)

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Any of the following conditions or situa

      28a - CLOSING CRITERIA (P)

      The pool was not closed by the operator or responsible supervisor under the following condition: i, emergency doors not self-closing and self-latching.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken: Reviewed requirements for

      28e -REPORTS AND RECORDS (Pf)

      On monthly pool logs, chemical testing is not at required frequency, monthly checks (pump safety, equipment safety) are not recorded, backwashing not indicated.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: PIC has plans to repair ri

      29g - DRINKING FOUNTAIN (P)

      The drinking fountain on the right side is not functional. The drinking fountain on the left side provides water.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS

      The pump room is not clean and sanitary, the floors have powdery residue, sand, debris, and trash.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken: CO detectors purchased and Corrected on site

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken: The west door blocked by r

      34d - DOOR/GATE (P)

      The emergency exit doors from the pool area to the outside are not self-closing or latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  4. Jan 15, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: PIC removed toys. Corrected on site

      04b - SKIMMERS/GUTTERS CLEANED

      Skimmers are not clean and have several toys inside.

      Correction: Maintain in a clean condition.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      One weir door is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: PIC restarted the machine. Corrected on site

      14e - WATER POTENTIAL ORP

      The water potential was blinking and reading 045mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: Send sanitarian photo's of Repeat

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for alkalinity is not in compliance with ATCP 76.18(3). Alkalinity is not documented. Pool was not tested yesterday.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: Tested both basins of wate Corrected on site

      23a - OPERATOR REQUIREMENT

      The operator is not correctly testing and noting chlorine on logs. Chlorine is documented with accuracy (decimal points) that are not possible with the Taylor kit. For example, chlorine is noted as 5.9 when operator uses 10mL of water and each drop equals 0.5ppm.

      Correction: Acquire or train an operator knowledgeable on pool operation and maintenance.

      Code ATCP 76.20(1)

    • Not serious Action taken: Employee immediately repla Corrected on site

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      First aid cabinet in pool area is empty.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

  5. Jul 25, 2023 Re-Inspection · Reinspection Required
    • Not serious Action taken: Sanitarian provided update Repeat

      20e - WATER TESTING FREQUENCY - ORP - Not Corrected

      The water testing frequency is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Jul 21, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04b - SKIMMERS/GUTTERS CLEANED

      Skimmers are not clean. Black/grey mold growth lines the entire inner rim above the skimmer baskets.

      Correction: Maintain in a clean condition.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      14a - CHLORINE TOO LOW

      The chlorine residual was 0.0 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [ ]. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken: Owner arrived onsite and r

      14e - WATER POTENTIAL ORP

      The water potential was 517 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16a - pH

      The pH is 7.0 and very yellow in color.

      Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Action taken: Repeat

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency is not in compliance with ATCP 76.18(3). Records of pool monitoring are not available.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      23d - NO RESPONSIBLE SUPERVISOR

      No responsible supervisor is monitoring pool regularly. Pool was not tested prior to opening. Owner was available by phone and arrived onsite for inspection.

      Correction: The pool must be closed until a responsible supervisor is available to fulfill the responsibilities.

      Code ATCP 76.21

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA

      The pool was not closed under the following conditions: 1) Emergency exit door that is not self-closing. 3) Zero chlorine in the pool basin, pH under 7.0 (yellow) 6) Absence of responsible supervisor monitoring the pool.

      Correction: Ensure that the closing criteria are adhered to under the listed below.

      Code ATCP 76.30

    • Not serious Action taken: PIC put on covers. Corrected on site

      31b - EQUIPMENT NOT MAINTAINED

      Feeder covers are missing on two of the feeders.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      34c - DOOR/GATE

      The door or gate for the east emergency exit is not self-closing. Door does latch when manually closed.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

    • Not serious Action taken: Pool closed based on inspe

      34d - POOL CLOSED SIGN

      Front desk staff informed sanitarian pool was closed verbally due to staff not being onsite to test. Pool entry was not locked, no signage was posted informing that the pool was closed, and patrons were swimming in the pool.

      Correction: Provide a sign that communicates to the public that the pool is closed.

      Code ATCP 76.34(5)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  7. Jul 21, 2023 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      04b - SKIMMERS/GUTTERS CLEANED - Not Corrected

      Skimmers are not clean. Black/grey mold growth lines the entire inner rim above the skimmer baskets.

      Correction: Maintain in a clean condition.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      14a - CHLORINE TOO LOW - Not Corrected

      The chlorine residual was 0.8 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to 1-10. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      16a - pH - Not Corrected

      The pH is 7.0 and very yellow in color.

      Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Action taken: Repeat

      20e - WATER TESTING FREQUENCY - ORP - Not Corrected

      The water testing frequency is not in compliance with ATCP 76.18(3). Records of pool monitoring are not available.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA - Not Corrected

      The pool was not closed under the following conditions: 1) Emergency exit door that is not self-closing. 3) Zero chlorine in the pool basin, pH under 7.0 (yellow)

      Correction: Ensure that the closing criteria are adhered to under the listed below.

      Code ATCP 76.30

    • Not serious Action taken: PIC worked to adjust the d

      34c - DOOR/GATE - Not Corrected

      The door or gate for the east emergency exit is not self-closing. Door does latch when manually closed.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  8. Mar 22, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional, float is stuck.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      14c - CHLORINE TOO HIGH

      The chlorine residual exceeded 10 ppm (13.4).

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range (1-10ppm). Call inspector to notify of the Cl level.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      20a - TEST KIT NOT APPROVED

      The test kit used by the facility has expired reagents.

      Correction: Replace the test kit with one from the approved list.

      Code ATCP 76.17(1)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for alkalinity is not in compliance with ATCP 76.18(3). Test and record alkalinity at least 1x/week.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  9. Feb 10, 2020 Routine Inspection · Reinspection Required

    No violations cited.

  10. Dec 3, 2018 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.