  1. Jun 4, 2026 Re-Inspection · Reinspection Required
    • Not serious Action taken: Discussed floating weir ba

      04c - SKIMMER BASKET/WEIR - Not Corrected

      1. Weir door is missing. 2. Spare pump basket missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: PIC filled water to adequa Corrected on site

      05b - WATER LEVEL (Pf) - Not Corrected

      The pool water level is not adequate for continuous effective surface skimming. Water level is barely reaching skimmers.

      Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continuous water supply over the gutter.

      Code ATCP 76.11(2)(a) and ATCP 76.19(3)

    • Not serious Action taken: PIC printed DATCP's interl

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected

      Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: PIC reset machine, machine Corrected on site

      14e - WATER POTENTIAL ORP (Pf) - Not Corrected

      The water potential was 418mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: PIC printed DATCP's templa

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan. Combined chlorine 1.6ppm at start of inspection.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken: Tested with PIC and review Repeat Corrected on site

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf) - Not Corrected

      The water testing frequency is not in compliance with ATCP 76.18(3). No documentation reported in June. May pool records report values such as free chlorine 7.1, 7.3, 7.5ppm when 1 drop = 0.2ppm. Combined chlorine values such as 0.3ppm reported.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: PIC placed online order.

      26g - BREATH HOLDING PROHIBITION - SIGNAGE - Not Corrected

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Post address by phone in p

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf) - Not Corrected

      The facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near or attached to the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken: Move required items to poo

      26q - FIRST AID KIT - AVAILABLE (P) - Not Corrected

      A first aid kit is not available in the pool area. First aid kit available at front desk area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)(a)

    • Not serious Action taken: PIC ordered supplies durin

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected

      Instant cold pack and emergency blankets are missing from the first aid kit. Eye wash is expired.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: PIC placed order online fo

      26t - BIOHAZARD SAFETY KIT (Pf) - Not Corrected

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Any of the following conditions or situa

      28a - CLOSING CRITERIA (P) - Not Corrected

      The pool was not closed by the operator or responsible supervisor under the following condition: i, emergency doors not self-closing and self-latching.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken: Reviewed requirements for

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      On monthly pool logs, chemical testing is not at required frequency, monthly checks (pump safety, equipment safety) are not recorded, backwashing not indicated.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: PIC has plans to repair ri

      29g - DRINKING FOUNTAIN (P) - Not Corrected

      The drinking fountain on the right side is not functional. The drinking fountain on the left side provides water.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS - Not Corrected

      The pump room is not clean and sanitary, the floors have powdery residue, sand, debris, and trash.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken: CO detectors purchased and Corrected on site

      32d - CARBON MONOXIDE ALARMS (P) - Not Corrected

      There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken: The west door blocked by r

      34d - DOOR/GATE (P) - Not Corrected

      The emergency exit doors from the pool area to the outside are not self-closing or latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  2. Jun 3, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken: Discussed floating weir ba

      04c - SKIMMER BASKET/WEIR

      1. Weir door is missing. 2. Spare pump basket missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: PIC filled water to adequa Corrected on site

      05b - WATER LEVEL (Pf)

      The pool water level is not adequate for continuous effective surface skimming. Water level is barely reaching skimmers.

      Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continuous water supply over the gutter.

      Code ATCP 76.11(2)(a) and ATCP 76.19(3)

    • Not serious Action taken: PIC printed DATCP's interl

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: PIC reset machine, machine Corrected on site

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 418mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: PIC printed DATCP's templa

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan. Combined chlorine 1.6ppm at start of inspection.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken: Tested with PIC and review Repeat Corrected on site

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency is not in compliance with ATCP 76.18(3). No documentation reported in June. May pool records report values such as free chlorine 7.1, 7.3, 7.5ppm when 1 drop = 0.2ppm. Combined chlorine values such as 0.3ppm reported.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: PIC placed online order.

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Post address by phone in p

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf)

      The facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near or attached to the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken: Move required items to poo

      26q - FIRST AID KIT - AVAILABLE (P)

      A first aid kit is not available in the pool area. First aid kit available at front desk area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)(a)

    • Not serious Action taken: PIC ordered supplies durin

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Instant cold pack and emergency blankets are missing from the first aid kit. Eye wash is expired.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: PIC placed order online fo

      26t - BIOHAZARD SAFETY KIT (Pf)

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Any of the following conditions or situa

      28a - CLOSING CRITERIA (P)

      The pool was not closed by the operator or responsible supervisor under the following condition: i, emergency doors not self-closing and self-latching.

      Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.

      Code ATCP 76.30

    • Not serious Action taken: Reviewed requirements for

      28e -REPORTS AND RECORDS (Pf)

      On monthly pool logs, chemical testing is not at required frequency, monthly checks (pump safety, equipment safety) are not recorded, backwashing not indicated.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken: PIC has plans to repair ri

      29g - DRINKING FOUNTAIN (P)

      The drinking fountain on the right side is not functional. The drinking fountain on the left side provides water.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS

      The pump room is not clean and sanitary, the floors have powdery residue, sand, debris, and trash.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken: CO detectors purchased and Corrected on site

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken: The west door blocked by r

      34d - DOOR/GATE (P)

      The emergency exit doors from the pool area to the outside are not self-closing or latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  3. Jan 15, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Weir door is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: PIC immediately increased Corrected on site

      14a - CHLORINE TOO LOW

      The chlorine residual was 1.8ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken: PIC restarted the machine. Corrected on site

      14e - WATER POTENTIAL ORP

      The water potential was blinking and reading 045mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: Send sanitarian photo's of Repeat

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for alkalinity is not in compliance with ATCP 76.18(3). Alkalinity is not documented. Pool was not tested yesterday.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: Tested both basins of wate Corrected on site

      23a - OPERATOR REQUIREMENT

      The operator is not correctly testing and noting chlorine on logs. Chlorine is documented with accuracy (decimal points) that are not possible with the Taylor kit. For example, chlorine is noted as 5.9 when operator uses 10mL of water and each drop equals 0.5ppm.

      Correction: Acquire or train an operator knowledgeable on pool operation and maintenance.

      Code ATCP 76.20(1)

    • Not serious Action taken: Employee immediately repla Corrected on site

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      First aid cabinet in pool area is empty.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

  4. Jul 25, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR - Not Corrected

      The weir door is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Repeat

      20e - WATER TESTING FREQUENCY - ORP - Not Corrected

      The water testing frequency is not in compliance with ATCP 76.18(3). Pool testing logs not available during inspection.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: Step tiles onsite, other t

      29b - BASIN DEFECTS - Not Corrected

      The pool basin and edge is missing tiles. A large step tile is missing, tiles on contrasting color are missing, and tiles on the vertical edge are missing leaving sharp edges.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      VGBA main drain log not available.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 21, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The weir door is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: Whirlpool drained.

      14a - CHLORINE TOO LOW

      The chlorine residual was 0.0 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [ ]. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 207 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: Whirlpool drained.

      16c - ALKALINITY

      The total alkalinity is 30.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken: Repeat

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency is not in compliance with ATCP 76.18(3). Pool testing logs not available during inspection.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: Discussed training staff o

      23d - NO RESPONSIBLE SUPERVISOR

      No responsible supervisor is monitoring pool regularly. Pool was not tested prior to opening. Owner was available by phone and arrived onsite for inspection.

      Correction: The pool must be closed until a responsible supervisor is available to fulfill the responsibilities.

      Code ATCP 76.21

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA

      The pool was not closed under the following condition: 1) Main drain missing screws. 3) Zero chlorine in basin. 6) Responsible supervisor not monitoring pool.

      Correction: Ensure that the closing criteria are adhered to under the listed below.

      Code ATCP 76.30

    • Not serious Action taken: Step tiles onsite, other t

      29b - BASIN DEFECTS

      The pool basin and edge is missing tiles. A large step tile is missing, tiles on contrasting color are missing, and tiles on the vertical edge are missing leaving sharp edges.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34e - VGBA COVERS

      1) Several screws missing on main drain. 2) No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  6. Mar 22, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      14c - CHLORINE TOO HIGH

      The chlorine residual exceeded 10 ppm (12.8).

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range (3-10ppm). Call inspector to notify of the Cl level.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.6ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer, combined chlorine shall not exceed 0.8ppm.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for alkalinity is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test and record alkalinity a least 1x/week.

      Code ATCP 76.18(3)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  7. Feb 10, 2020 Routine Inspection · Reinspection Required

    No violations cited.

  8. Dec 3, 2018 Pre-Inspection · No Reinspection Required

    No violations cited.