The James
432 W Gorham ST, Madison, WI 53703 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2017-00236
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 0 |
| 2025 | 1 | 10 | 0 |
| 2023 | 1 | 0 | 0 |
| 2022 | 2 | 4 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
Inspections
-
Jul 22, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
25n - LIFEGUARD - SIGNAGE (Ppf)
The lettering on the sign posted indicating there is no lifeguard is less than 4 inches.
Correction: Post an approved sign with letters at least 4 inches high stating: "Warning: No Lifeguard on Duty."
Code ATCP 76.23(2)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING (Pf)
The lettering of the 'NO DIVING' sign posted is less than 4 inches.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken:
-
Jul 8, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Variance application and f
02b - VARIANCE (P)
The operator is not complying with the condition's of an approved variance. Facility uses a push button emergency pool phone that requires a variance by administrative rule.
Correction: Comply with the approved variance and maintain a copy of the approved variance at the pool.
Code ATCP 76.02(2)(b)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Doors to pump room where chemicals are stored are not marked to indicate entry is for authorized personnel only.
Correction: Doors to chemical storage areas shall be locked and marked to indicate entry is for authorized personnel only.
Code ATCP 76.12(2)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP (Pf)
The water potential was 590 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV. Test whirlpool for pH and free chlorine 4 times per day until electronic controller is functioning properly.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
16b - CYANURIC ACID (Pf)
The cyanuric acid concentration is 50ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken: Template provided with ema
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e).
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING (Ppf)
A pool basin in the facility does not have a 'Warning: No Lifeguard on Duty' sign in 4 inch letters.
Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.23(2)
-
Not serious
Action taken:
26q - FIRST AID KIT - AVAILABLE (P)
The first aid kit in the pool area is in poor condition and not maintained.
Correction: Provide a first aid kit in the pool area in good condition and maintained.
Code ATCP 76.27(1)(a)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING (Pf)
'NO DIVING' is not posted in the pool rules in 4 inch letters.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(d)
-
Not serious
a. Do not enter the pool if you have a c
27e - SIGNAGE - POOL RULES
A pool rules sign is not conspicuously posted in the whirlpool area.
Correction: Provide a sign in compliance with ATCP 76.29(1)(b) and (c).
Code ATCP 76.29(1)(b) and (c) ATCP 76.29(1)(b-c)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available onsite for the manufacturer's pump performance curve.
Correction: Provide a pump curve for the recirculation pump. Maintain documentation onsite and make available upon request.
Code ATCP 76.38
-
Not serious
Action taken: Variance application and f
-
Jul 18, 2023 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 22, 2022 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING - Not Corrected
A pool basin in the facility does have a 'No Lifeguard on Duty' sign, but it's less than 4 inches high
Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.22(1)(c); ATCP 76.23(2)
-
Not serious
Action taken:
-
Aug 18, 2022 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm, it was at 11 ppm at the time of the inspection
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
16a - pH
The pH is 8.0 ppm.
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING
A pool basin in the facility does have a 'No Lifeguard on Duty' sign, but it's less than 4 inches high
Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.22(1)(c); ATCP 76.23(2)
-
Not serious
Action taken:
-
Jul 15, 2021 Routine Inspection · Reinspection Required
No violations cited.
-
Aug 19, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 28, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
May 24, 2017 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.