The Park Apartment Homes

6201 WILLIAMSBURG WAY, Deforest, WI 53532 · Dane County

20cited violations
0serious tier
8inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2020-00139
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026210
20252110
2024140
2023140
2021100
2020100

Inspections

  1. Sep 23, 2026 Routine Inspection · No Reinspection Required

    No violations cited.

  2. Feb 11, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 230 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

  3. Jul 31, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR - Not Corrected

      The skimmer weir is broken.

      Correction: Replace weir or install floating weir.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: 7/31/2025 re-inspection -

      16c - ALKALINITY (Pf) - Not Corrected

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: 7/31/2025 re-inspection: T

      20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected

      The test kit reagents are not stored properly, replaced as required, or being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf) - Not Corrected

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test combined chlorine level daily.

      Code ATCP 76.18(2)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site for VGBA main drain cover showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA cover for main drain on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  4. Jul 31, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is broken.

      Correction: Replace weir or install floating weir.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      14a - CHLORINE TOO LOW (P)

      The chlorine residual was 1.8 ppm (tested twice) at the time of the inspection. Degree of error with test kit results that free chlorine level could be 1.5 ppm - 2.1 ppm which is too low.

      Correction: Close the pool and raise the chlorine residual to 3.0 ppm. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagents are not stored properly, replaced as required, or being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2). Test combined chlorine level daily.

      Code ATCP 76.18(2)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain cover showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA cover for main drain on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  5. Jul 11, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE

      Liquid chlorine is stored directly over acid on a shelf in the pump room.

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

  6. Jul 19, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The skimmer weir is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 582 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.2.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a non-chlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE

      The water testing frequency for combined chlorine and alkalinity is not in compliance with ATCP 76.18(2).

      Correction: Perform water testing in accordance with ATCP 76.18(2). Combined chlorine must be tested at least 2x/week and total alkalinity tested at least 1x/week. Ensure free chlorine reading is recorded in proper column of testing log.

      Code ATCP 76.18(2)

  7. Jul 1, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 5, 2020 Pre-Inspection · Reinspection Required

    No violations cited.