Elevate Apartments

5022 American PKWY, Madison, WI 53718 · Dane County

36cited violations
0serious tier
7inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2021-00418
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262150
2025160
20243150
2021100

Inspections

  1. Jul 28, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      25n - LIFEGUARD - SIGNAGE (Ppf) - Not Corrected

      No Lifeguard on Duty signage has lettering that is less than 4 inches high.

      Correction: Post an approved sign with letters at least 4 inches high stating: "Warning: No Lifeguard on Duty."

      Code ATCP 76.23(2)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE - Not Corrected

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

  2. Jul 22, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      14a - CHLORINE TOO LOW (P)

      The chlorine residual was 0.2 ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to between 1.0 ppm to 10 ppm. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 523 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16a - pH (P)

      The pH is under 7.0. Per reading in pump room, electronic system says it is at 6.3

      Correction: Maintain the pH between 7.2 and 7.8. Close pool and call inspector to schedule a re-opening inspection.

      Code ATCP 76.14(5)(c)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: A new kit with reagents wi Corrected on site

      20b - TEST KIT REAGENT STORAGE (Pf)

      The reagents in the two testing kits in the pump room are expired. One kit has reagents from 2022.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      There is not water testing log onsite and accessible to employees onsite to review for inspection.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      25n - LIFEGUARD - SIGNAGE (Ppf)

      No Lifeguard on Duty signage has lettering that is less than 4 inches high.

      Correction: Post an approved sign with letters at least 4 inches high stating: "Warning: No Lifeguard on Duty."

      Code ATCP 76.23(2)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26n - TELEPHONE - NOT WORKING (P)

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately. Pool must remain closed until phone is working. Close pool and contact inspector to schedule a reopening inspection.

      Code ATCP 76.26(2)

    • Not serious Action taken: A new first aid kit is in Corrected on site

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Eye wash is missing from the first aid kit. Some bandages appear to have been water damaged in kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      Electronic monitoring system in pump room has an alarm notification.

      Correction: Properly locate, intall, maintain and repair equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      Documentation shows that the 3 drain grate covers (Aquastar model 32CDFL101) expired as of 7/15/2026. They have a 5 year life span and were installed on 7/15/2021.

      Code ATCP 76.38

  3. Aug 6, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 574 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for Combined Chlorine and Cyanuric acid is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Combined chlorine. If chlorine is used, the water shall also be tested at least twice a week for the combined chlorine level. Pf. Cyanuric acid. If cyanuric acid is used in the water basin, the cyanuric acid concentration in the water shall be tested at least once a week. Pf.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Eye Wash and Resuscitation pocket face mask are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      27c - SIGNAGE - SMALL LETTERS

      The letters on the pool rules signage are less than one inch in height.

      Correction: Provide an approved sign.

      Code ATCP 76.29(1)

  4. Jul 1, 2024 Re-Inspection · No Reinspection Required

    No violations cited.

  5. Jun 28, 2024 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR - Not Corrected

      One of the skimmer weirs is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Repeat

      14a - CHLORINE TOO LOW - Not Corrected

      The chlorine residual was 0.4-0.8 ppm at the time of the inspection. Measurements were taken in multiple locations including the sample port in the pump room.

      Correction: Close the pool and raise the chlorine residual to 1.5-10 ppm (can be 1-10 ppm now that electronic monitoring device is working). Call inspector to schedule a reopening inspection. Pool must maintain proper chlorine residual using the automatic disinfection system.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS - Not Corrected

      Due to pool being closed, did not check testing logs for pool code requirements. Will reiterate requirements at next re-inspection.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken: Repeat

      26m - TELEPHONE - NOT WORKING - Not Corrected

      The emergency telephone is not working properly. It does dial to 911, but the call was cutting out at multiple points until it cut out completely while still trying to talk to the 911 operator.

      Correction: Provide a functional emergency telephone immediately. Pool may not reopen until this phone is working properly.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26o - EMERGENCY NUMBERS AND ADDRESS - Not Corrected

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

  6. Jun 18, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      One of the skimmer weirs is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Repeat

      14a - CHLORINE TOO LOW

      The chlorine residual was 0-0.2 ppm at the time of the inspection. Measurements were taken twice at opposite sides of the pool.

      Correction: Close the pool and raise the chlorine residual to 1.5-10 ppm. Call inspector to schedule a reopening inspection. Pool must maintain proper chlorine residual using the automatic disinfection system.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 208 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16a - pH

      The pH is 8.0.

      Correction: Maintain pH between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Action taken: Repeat

      16c - ALKALINITY

      The total alkalinity is 260 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      Looked through all the water testing logs in the pump room with the Assistant Property Manager, and did not find any current test logs.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken: Repeat

      26m - TELEPHONE - NOT WORKING

      The emergency telephone is not working properly. It does dial to 911, but the call was cutting out at multiple points until it cut out completely while still trying to talk to the 911 operator.

      Correction: Provide a functional emergency telephone immediately. Pool may not reopen until this phone is working properly.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26o - EMERGENCY NUMBERS AND ADDRESS

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious Action taken: Repeat

      26p - FIRST AID KIT - AVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      An alarm light is on the electronic monitoring device in the pump room.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  7. Jul 29, 2021 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 3, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.