La Quinta Inn & Suites
5217 East Terrace DR, Madison, WI 53718 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2022-00508
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 5 | 0 |
| 2024 | 1 | 5 | 0 |
| 2023 | 1 | 5 | 0 |
| 2022 | 1 | 7 | 0 |
Inspections
-
Mar 9, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(3). Combined chlorine must be tested at least 2x per week.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: There is a working drinkin
29g - DRINKING FOUNTAIN (P)
The drinking fountain in the pool enclosure is not operational.
Correction: Repair the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Nov 18, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Ecolab tech was onsite to
Corrected on site
14a - CHLORINE TOO LOW
The chlorine residual was 0.6 ppm at the time of the inspection.
Correction: Whirlpool chlorine residual must be maintained between 3.0 and 10.0 ppm
Code ATCP 76.14(4)(a)
-
Not serious
Action taken:
20b - TEST KIT REAGENT STORAGE
The test kit reagents are expired.
Correction: Replace expired reagents.
Code ATCP 76.17(2)
-
Not serious
Action taken: Phone line tech onsite dur
Corrected on site
26m - TELEPHONE - NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken: Manager moved information
Corrected on site
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and/or the facility's location are not posted near the designated emergency phone. They were taped to a table not near the emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken: Ecolab tech onsite during
Corrected on site
31b - EQUIPMENT NOT MAINTAINED
An alarm is present on the electronic monitoring system in the pump room.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken: Ecolab tech was onsite to
Corrected on site
-
Dec 19, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
Repeat
04c - SKIMMER BASKET/WEIR
The skimmer weir is missing.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
Repeat
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). Combined chlorine for a whirlpool must be tested at least 1x daily.
Correction: Perform water testing in accordance with ATCP 76.18(2).
Code ATCP 76.18(2)
-
Not serious
Action taken:
26p - FIRST AID KIT - AVAILABLE
A first aid kit is not available in the pool area. It is located at the front desk which is more than 25 feet away from the pool enclosure.
Correction: Provide a first aid kit in the pool area or within 25 feet of the pool enclosure.
Code ATCP 76.27(1)
-
Not serious
Action taken:
Repeat
29g - DRINKING FOUNTAIN
The drinking fountain is not functional and not clean.
Correction: Repair/clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
Repeat
-
Aug 12, 2022 Pre-Inspection · No Reinspection Required
-
Not serious
Action taken:
04c - SKIMMER BASKET/WEIR
The skimming weir is missing.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) for the recirculation pump is not available onsite.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
16d - COMBINED CHLORINE
The combined chlorine is 1.2ppm.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(2). Combined chlorine must be tested and recorded at least 2x/week.
Code ATCP 76.18(2)
-
Not serious
Action taken: Manager provided a working
Corrected on site
26m - TELEPHONE - NOT WORKING
The emergency telephone does not work. Not consistently getting a dial-tone.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
29f - DEPTH MARKINGS VISIBLE
The depth markings along the edge of the pool on interior wall are fading and stained.
Correction: Repair the markings so they are clearly visible and readable.
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN
The drinking fountain is not clean.
Correction: Repair/clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
Source: Public Health Madison & Dane County. History last read Nov 3, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.