Mainstay Suites
5317 High Crossing BLVD, Madison, WI 53718 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2015-00275
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 0 |
| 2025 | 1 | 3 | 0 |
| 2024 | 1 | 3 | 0 |
| 2023 | 1 | 5 | 0 |
| 2021 | 2 | 21 | 0 |
| 2019 | 8 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
Inspections
-
Sep 2, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
Corrected on site
05b - WATER LEVEL (Pf)
The pool water level is not adequate for continuous effective surface skimming. Water level is too high.
Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continous water supply over the gutter.
Code ATCP 76.11(2)(a) and ATCP 76.19(3)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: Pool closed. Operator adju
Corrected on site
14f - NO DISINFECTANT FEEDER (P)
The pool is not being automatically and continually disinfected via a disinfectant feeder. The operator is turning the disinfectant feeder on and off to manually adjust the chlorine level.
Correction: The pool must be closed and a disinfectant feeder, approved by the department of commerce, must be installed or functional before the facility can re-open.
Code ATCP 76.14(1)
-
Not serious
Action taken: Operator adjusted the pH t
Corrected on site
16a - pH (P)
The pH is over 8.0 ppm
Correction: Maintain the pH between 7.2 and 7.8.
Code ATCP 76.14(5)(c)
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan or is not following combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf)
Elastic bandage and disposable gloves are missing from the first aid kit. The eye wash is expired.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Any of the following conditions or situa
Corrected on site
28a - CLOSING CRITERIA (P)
The pool was not closed by the operator or responsible supervisor under the following condition: nonoperational disinfectant feeder.
Correction: Ensure that the closing criteria are adhered to under the listed below and post signage indicating closure.
Code ATCP 76.30
-
Not serious
Action taken:
Corrected on site
-
Nov 24, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Adjusted during the inspec
Corrected on site
16a - pH (P)
The pH is >8.0 according to Taylor test kit reading; reading could be 8.0 due to degree of error.
Correction: Maintain the pH between 7.2 and 7.8.
Code ATCP 76.14(5)(c)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken: Reading were callibrated d
Corrected on site
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Chemtrol meter in the pump room is not accurately reading the pH. The meter is reading 7.3 and the water tests are 8.0 or higher.
Correction: Properly locate, install, maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken: Adjusted during the inspec
Corrected on site
-
Jul 15, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing log is missing total alkalinity test results.
Correction: Perform water testing in accordance with ATCP 76.18(1). Test total alkalinity at least once a week.
Code ATCP 76.18(1)
-
Not serious
Any of the following conditions or situa
Corrected on site
28a - CLOSING CRITERIA
The pool was not closed under the following condition: missing equalizer cover on the pool basin wall.
Correction: Ensure that the closing criteria are adhered to under the listed below.
Code ATCP 76.30
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA equalizer covers showing make/model, installation, and replacement date. Equalizer cover information is missing on the VGBA log.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 9, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
04c - SKIMMER BASKET/WEIR
The skimmer weir door is missing.
Correction: Replace skimmer weir door or install floating weir.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
20a - TEST KIT NOT APPROVED
The test kit used by the facility has not been approved by the department. The reagents are expired and the color comparator is dirty.
Correction: Replace the test kit with one from the approved list. Provide a new pool test kit.
Code ATCP 76.17(1)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency is not in compliance with ATCP 76.18(1). Total alkalinity tests are not completed. Combined chlorine test values on the log are inaccurate and do not reflect testable range values.
Correction: Perform water testing in accordance with ATCP 76.18(1). Test total alkalinity at least once weekly. Test combined chlorine 2 times per week. Test pH and free chlorine at least once daily.
Code ATCP 76.18(1)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Dec 28, 2021 Re-Inspection · Reinspection Required
-
Not serious
Action taken:
20a - TEST KIT NOT APPROVED - Not Corrected
The following test kit reagent used by the facility has been expired: DPD Powder expired 06/21.
Correction: Replace the test kit with one from the approved list.
Code ATCP 76.17(1)
-
Not serious
Action taken: Operated temporarily poste
26o - EMERGENCY NUMBERS AND ADDRESS - Not Corrected
The emergency numbers and/or the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING - Not Corrected
'NO DIVING' posted in the pool area is less than 4 inches in height.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Action taken:
29a - FACILITY CLEANING - Not Corrected
The pump including the small room storing the chemicals is wet, dirty and is in need of cleaning. The chemical small room is still in need of cleaning.
Correction: Keep the facility in a clean condition pursuant to ATCP 76.33(1)(a).
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN - Not Corrected
The drinking fountain is not functional or not clean.
Correction: Repair/clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
30e - SOAP - Not Corrected
The soap dispenser in shower is empty.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Dec 3, 2021 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
05a - SKIMMER/MAIN DRAIN RATIO
The skimmer to main drain flow ratio is not set correctly.
Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken:
13c - DISINFECTANT FEEDER - NOT ELECTRICALLY CONNECTED
The disinfectant feeder pump is not electrically connected to the recirculation pump control circuit. The pool operator could not demonstrate if the disinfectant feeder pump is electrically connected to the recirculation pump.
Correction: Electrically connect the disinfectant feeder to the recirculation pump so it cannot keep running when the recirculation pump is turned off.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
16a - pH
The pH is 8.0 ppm.
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 310 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken:
20a - TEST KIT NOT APPROVED
The following test kit reagent used by the facility has been expired: DPD Powder expired 06/21.
Correction: Replace the test kit with one from the approved list.
Code ATCP 76.17(1)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and/or the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING
NO DIVING' posted in the pool area is less than 4 inches in height.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Any of the following conditions or situa
28a - CLOSING CRITERIA
The pool was not closed under the following condition: Free chlorine and pH are outside of the acceptable range.
Correction: Ensure that the closing criteria are adhered to under the listed below.
Code ATCP 76.30
-
Not serious
Action taken:
29a - FACILITY CLEANING
The pump including the small room storing the chemicals is wet, dirty and is in need of cleaning.
Correction: Keep the facility in a clean condition pursuant to ATCP 76.33(1)(a).
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN
The drinking fountain is not functional or not clean.
Correction: Repair/clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
30b - SHOWERS
The soap dispenser in the bathroom and shower is empty.
Correction: Repair the showers.
Code ATCP 76.33(2)(b)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Sep 3, 2019 Re-Inspection · No Reinspection Required
No violations cited.
-
Aug 23, 2019 Re-Inspection · Reinspection Required
No violations cited.
-
Aug 13, 2019 Re-Inspection · Reinspection Required
No violations cited.
-
Jul 17, 2019 Re-Inspection · No Reinspection Required
No violations cited.
-
Jun 26, 2019 Re-Inspection · Reinspection Required
No violations cited.
-
Jun 14, 2019 Re-Inspection · Reinspection Required
No violations cited.
-
May 31, 2019 Re-Inspection · Reinspection Required
No violations cited.
-
May 7, 2019 Routine Inspection · Reinspection Required
No violations cited.
-
May 24, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 28, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Mar 2, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Sep 22, 2015 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 3, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.