RecordWell Data

Raven Apartments

5116 LACY RD, Fitchburg, WI 53711 · Dane County

10cited violations
0serious tier
6inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2019-00239
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
2025100
2024150
2022150
2021100
2019100

Inspections

  1. Jun 3, 2026 Routine Inspection · No Reinspection Required

    No violations cited.

  2. Jun 11, 2025 Routine Inspection · No Reinspection Required

    No violations cited.

  3. Jun 26, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the pool skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 50 ppm

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

    • Not serious Other Corrected on site

      41c - MISCELLANEOUS

      There is no carbon monoxide detector in pool pump room with fuel burning appliance (water heater).

      Correction: A pool equipment room that has a fuel burning appliance shall install and maintain a carbon monoxide alarm. Provide a carbon monoxide detector.

      Code ATCP 76.33 Facility maintenance, repair, and sanitation. - 4

  4. Jul 14, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      One weir door is missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Corrected on site

      14c - CHLORINE TOO HIGH

      The chlorine residual tested at beginning of inspection at 13.4. Technician worked to lower chlorine levels to 10.2 by end of inspection.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      The test kit reagents for chlorine are empty and or expired. Pool testing company technician using expired reagents.

      Correction: Replace testing reagents as recommended by the manufacturer.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      Biohazard kit's gown is shredded and the gloves are deteriorating.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jun 16, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jul 8, 2019 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 3, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.