| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2022 | 1 | 5 | 0 |
Inspections
-
Jul 21, 2022 Pre-Inspection · No Reinspection Required
-
Not serious
Action taken:
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm., (22ppm).
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
20a - TEST KIT NOT APPROVED
The test kit used by the facility has not been approved by the department.
Correction: Replace the test kit with one from the approved list.
Code ATCP 76.17(1)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for pH and free chlorine is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). water shall be tested for pH and disinfectant residual daily before the pool is open to the public or before the pool is in use, and at least one other time during the day’s peak patron load
Code ATCP 76.18(1)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Items are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit. The first aid kit shall contain all of the following items: (a) Gauze pads ? 4 x 4 . (b) Gauze pads – 8 x 10 . (c) Adhesive bandages. (d) Triangular bandages. (e) Scissors. (f) Gauze roller bandage. (g) Tweezers. (h) Adhesive tape. (i) Eye wash. (j) Elastic bandage. (k) Disposable surgical gloves. (L) Resuscitation pocket face mas
Code ATCP 76.27(1)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.