2026260
2025170
2024140

Inspections

  1. Aug 31, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals are improperly stored in accordance with ATCP 76.12(2). There are spill prevention pallets for main supply of chlorine and acid, but no additional spill prevention pallets for back-up supply.

      Correction: Store chemicals in accordance with ATCP 76.12(2). Provide additional spill prevention pallets for back-up supply of chlorine and acid.

      Code ATCP 76.12(2)

    • Not serious Action taken: discussed plan with Tom an

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan. Combined chlorine at 0.8ppm.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      First aid kit in need of re-stock/replacement.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf)

      2 conventional or emergency blankets are not available in the pool area.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      29a - BASIN CLEANING

      Pool basin tiles at the waterline are need of cleaning.

      Correction: Keep the basin in a clean and sanitary condition pursuant to ATCP 76.33(1)(a).

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      30e - SOAP (Pf)

      The soap dispenser at hand sink in right-side restroom is empty.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

  2. Aug 28, 2026 Re-Inspection · No Reinspection Required

    No violations cited.

  3. Sep 23, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill protection provided in chemical storage closet to prevent accidental mixing of chlorine and acid.

      Correction: Store chemicals in accordance with ATCP 76.12(2). Provide overspill containment pallet or other means to prevent accidental mixing of chlorine and acid.

      Code ATCP 76.12(2)

    • Not serious Action taken: sanitarian will email Tom

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan or is not following combined chlorine plan. Combined chlorine level in swim pool measured at 0.8ppm.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e). Superchlorinate to breakpoint when the combined chlorine is >0.4ppm.

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Tom repaired the connectio Corrected on site

      26n - TELEPHONE - NOT WORKING (P)

      The emergency telephone does not work properly, no dial tone and line sounds crackly.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      29a - BASIN CLEANING

      Pool basin tiles at the waterline are in need of cleaning.

      Correction: Keep the basin in a clean and sanitary condition pursuant to ATCP 76.33(1)(a).

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      The pool areas are not maintained in good repair or are not being cleaned and disinfected regularly. Pool operator indicated that front desk do staff sweep/vacuum deck, but was not aware of any disinfection process.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b). Deck must be rinsed, as needed, and disinfected at least weekly.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      Acid and chlorine injectors appear to be leaking to buckets.

      Correction: Repair/replace acid and chlorine injector valves. Properly locate, install, maintain and repair all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other Corrected on site

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  4. Aug 15, 2024 Pre-Inspection · No Reinspection Required
    • Not serious Action taken: Rob moved ammonia bottle t Corrected on site

      11b - CHEMICAL - STORAGE

      Chemicals are improperly stored in accordance with ATCP 76.12(2). Bottle of ammonia stored on shelf above liquid chlorine.

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Action taken:

      16d - COMBINED CHLORINE

      The combined chlorine is 1.2 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a non-chlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Action taken:

      29a - FACILITY CLEANING

      Tiles on the side walls of the pool are in need of cleaning/scrubbing to remove visible build-up and to prevent the formation of biofilm.

      Correction: Keep the facility in a clean condition pursuant to ATCP 76.33(1)(a).

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Injector ports for chlorine and acid observed with chemical build-up and buckets placed underneath for possible leaks.

      Correction: Repair and maintain all equipment. If needed, repair/replace chlorine and acid injector ports to prevent any leaks.

      Code ATCP 76.33(1)(e)

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.