Greenbriar Apartments
222 RANDOLPH DR, Madison, WI 53717 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 17729-3953
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 6 | 0 |
| 2025 | 1 | 8 | 0 |
| 2024 | 1 | 6 | 0 |
| 2023 | 1 | 6 | 0 |
| 2022 | 1 | 6 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 22, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
08a - RECIRCULATION RATE - SWIM/COMBO (Pf)
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.
Code ATCP 76.11(4)(c)
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf)
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
16b - CYANURIC ACID (Pf)
The cyanuric acid concentration is 70ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for pH and free chlorine is not in compliance with ATCP 76.18(3). ORP reading at time of inspection was 590mV.
Correction: Perform water testing in accordance with ATCP 76.18(3). If ORP is not within range 650-900mV, then pool must be tested 2x/day for pH and free chlorine.
Code ATCP 76.18(3)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
29b - BASIN MAINTENANCE AND REPAIR
The paint on the floor/walls of the deep end of the pool basin is peeling, rough, and in need of resurfacing/repainting.
Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
-
Aug 22, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional or installed properly.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken: sanitarian recommended ins
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill protection to prevent accidental mixing of acid and chlorine/bromine.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken:
16b - CYANURIC ACID (Pf)
The cyanuric acid concentration is 50ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(5)(b)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency for alkalinity, combined chlorine, and cyanuric acid are not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record alkalinity 1x/week, combined chlorine 2x/week, and cyanuric acid 1x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
29b - BASIN MAINTENANCE AND REPAIR
The pool basin is in need of resurfacing/painting.
Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
29f - DEPTH MARKINGS VISIBLE (Pf)
The 4' depth markings along the edge of the pool are fading or otherwise not visible.
Correction: Repair the markings so they are clearly visible and readable.
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken:
-
Aug 23, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Matt repaired emergency ph
Corrected on site
26m - TELEPHONE - NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken: If blankets continue to be
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Pool operator and office staff indicated that the main drain covers are due for replacement next year and that Badger Pools has records for all drain/equalizer covers.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 21, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is between 30-40ppm (too low).
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine, alkalinity, and cyanuric acid is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week, alkalinity 1x/week, and cyanuric acid 1x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken:
29f - DEPTH MARKINGS VISIBLE
The depth markings along the deck of the shallow edge of the pool are fading or otherwise not visible.
Correction: Repair the markings so they are clearly visible and readable.
Code ATCP 76.33(1)(b)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 20, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) for the recirculation pump is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
26f - PATRON LOAD - NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken: Pool operator placed an or
26p - FIRST AID KIT - AVAILABLE
A first aid kit is not available in the pool area.
Correction: Provide a first aid kit in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken:
29f - DEPTH MARKINGS VISIBLE
The depth markings along the edge of the pool are fading or otherwise not visible.
Correction: Repair the markings so they are clearly visible and readable.
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
-
Aug 10, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 14, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 6, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 13, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
May 29, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 23, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 18, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 20, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.