  1. Jul 22, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO (Pf)

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 70ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for pH and free chlorine is not in compliance with ATCP 76.18(3). ORP reading at time of inspection was 590mV.

      Correction: Perform water testing in accordance with ATCP 76.18(3). If ORP is not within range 650-900mV, then pool must be tested 2x/day for pH and free chlorine.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      21d - READABLE CHART

      There is no readable chart that describes the piping, valves, and direction of water flow.

      Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.

      Code ATCP 76.11(5m)(b)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The paint on the floor/walls of the deep end of the pool basin is peeling, rough, and in need of resurfacing/repainting.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

  2. Aug 22, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional or installed properly.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: sanitarian recommended ins

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill protection to prevent accidental mixing of acid and chlorine/bromine.

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 50ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for alkalinity, combined chlorine, and cyanuric acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record alkalinity 1x/week, combined chlorine 2x/week, and cyanuric acid 1x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      21d - READABLE CHART

      There is no readable chart that describes the piping, valves, and direction of water flow.

      Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.

      Code ATCP 76.11(5m)(b)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The pool basin is in need of resurfacing/painting.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29f - DEPTH MARKINGS VISIBLE (Pf)

      The 4' depth markings along the edge of the pool are fading or otherwise not visible.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

  3. Aug 23, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken: Matt repaired emergency ph Corrected on site

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken: If blankets continue to be

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Pool operator and office staff indicated that the main drain covers are due for replacement next year and that Badger Pools has records for all drain/equalizer covers.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Jul 21, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is between 30-40ppm (too low).

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine, alkalinity, and cyanuric acid is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week, alkalinity 1x/week, and cyanuric acid 1x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      29f - DEPTH MARKINGS VISIBLE

      The depth markings along the deck of the shallow edge of the pool are fading or otherwise not visible.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 20, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) for the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      26f - PATRON LOAD - NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken: Pool operator placed an or

      26p - FIRST AID KIT - AVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      29f - DEPTH MARKINGS VISIBLE

      The depth markings along the edge of the pool are fading or otherwise not visible.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

  6. Aug 10, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Aug 14, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 6, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 5, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 13, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  11. May 29, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jun 23, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jun 18, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Jun 20, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.