Greenbriar Apartments
222 RANDOLPH DR, Madison, WI 53717 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 17729-42520
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 4 | 0 |
| 2025 | 1 | 7 | 0 |
| 2024 | 2 | 11 | 0 |
| 2023 | 1 | 8 | 0 |
| 2022 | 1 | 2 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 2 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 22, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11e - SDS AVAILABILITY (Pf)
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken:
29a - BASIN CLEANING
Basin has sediment or sand and is in need of cleaning.
Correction: Keep the basin in a clean and sanitary condition pursuant to ATCP 76.33(1)(a).
Code ATCP 76.33(1)(a)
-
Not serious
Other
Corrected on site
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Aug 22, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: sanitarian recommended pro
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill containment provided to prevent acid from mixing with bromine/chlorine.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken: whirlpool closed. Pool man
Corrected on site
14d - BROMINE TOO HIGH (P)
Initial bromine level was too low, 2.25ppm. Pool manager adjusted bromine level, then the bromine residual exceeded 10 ppm.
Correction: The pool must be closed and may not reopen until the bromine residual comes into an acceptable range 4.0-10ppm. Call inspector to notify of the Br level.
Code ATCP 76.14(4)(g)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)
The water testing frequency for alkalinity is not in compliance with ATCP 76.18(2).
Correction: Perform water testing in accordance with ATCP 76.18(2). Test/record alkalinity 1x/week.
Code ATCP 76.18(2)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken: new phone installed during
Corrected on site
26n - TELEPHONE - NOT WORKING (P)
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken: sanitarian recommended pro
-
Aug 28, 2024 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
08d - RECIRCULATION RATE - WHIRLPOOL - Not Corrected
The whirlpool has a maximum turnover rate of greater than 30 minutes. Turnover rate calculated at 41 minutes.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 30 minutes.
Code ATCP 76.11(4)(d)
-
Not serious
Action taken:
11e - SDS AVAILABILITY - Not Corrected
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Pool operator and office staff indicated that the main drain covers will be due for replacement next year and that this is managed by Badger Pools.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 23, 2024 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
08d - RECIRCULATION RATE - WHIRLPOOL
The whirlpool has a maximum turnover rate of greater than 30 minutes. Turnover rate calculated at 41 minutes.
Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 30 minutes.
Code ATCP 76.11(4)(d)
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken: Matt repaired the emergenc
Corrected on site
26m - TELEPHONE - NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken: OK to keep emergency blank
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Any of the following conditions or situa
28a - CLOSING CRITERIA
The pool was not closed under the following condition: 2 screws missing from main drain covers, emergency phone was not working.
Correction: Ensure that the closing criteria are adhered to under the listed below.
Code ATCP 76.30
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Pool operator and office staff indicated that the main drain covers will be due for replacement next year and that this is managed by Badger Pools.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 21, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
05a - SKIMMER/MAIN DRAIN RATIO
The skimmer to main drain flow ratio is not set correctly. Main drain valve appears to be full open.
Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken: Pool operator (Brian) adju
Corrected on site
16a - pH
The pH is above 8.0.
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency for alkalinity is not in compliance with ATCP 76.18(2).
Correction: Perform water testing in accordance with ATCP 76.18(2). Test/record reading for alkalinity 1x/week.
Code ATCP 76.18(2)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS
The hose bibb for the water supply line is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb. Do not allow hose to rest inside water supply line.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken: Gary made adjustments to s
Corrected on site
34c - DOOR/GATE
The exterior door to the whirlpool enclosure is not self-latching.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 20, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) for the recirculation pump is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 448mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
-
Aug 10, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Dec 5, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 6, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 13, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
May 29, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jan 23, 2015 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 23, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 18, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 20, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.