RecordWell Data

Harbor House Condominiums

802 HARBOR HOUSE DR, Madison, WI 53719 · Dane County

26cited violations
0serious tier
15inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
69850-74603
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026190
2025250
2024140
2022280
2021100
2019100
2018100
2017200
2015100
2014100
2013100
2012100

Inspections

  1. Jul 31, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO (Pf)

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours. It is 7.4 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken:

      21c - DIRECTION OF FLOW

      The water treatment system piping is not marked with a permanent label indicating direction of flow.

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

    • Not serious Action taken:

      21d - READABLE CHART

      There is no readable chart that describes the piping, valves, and direction of water flow.

      Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.

      Code ATCP 76.11(5m)(b)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING (Ppf)

      A pool basin in the facility does not have a 'Warning: No Lifeguard on Duty' sign.

      Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.23(2)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Elastic bandage is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      27c - SIGNAGE - SMALL LETTERS

      The letters on the pool rules signage are less than one inch in height.

      Correction: Provide an approved sign.

      Code ATCP 76.29(1)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' is not posted in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

    • Not serious a. Do not enter the pool if you have a c

      27e - SIGNAGE - POOL RULES

      There is a sauna. Showering before entering the pool and after the use of a sauna is not included in the pool rules.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b).

      Code ATCP 76.29(1)(b)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Jul 29, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Operator to drain pool and

      16b - CYANURIC ACID (Pf) - Not Corrected

      The cyanuric acid concentration is 40 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

  3. Jul 21, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04a - SKIMMER FUNCTION (Pf)

      The 2 skimmers located on the Northwest side of the pool are not adequately removing surface debris.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 40 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      Operator missing alkalinity testing reagents.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken: In order to avoid a subseq Repeat

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for alkalinity is not in compliance with ATCP 76.18(3). Additionally, pH and disinfectant are not being tested for on the weekends.

      Correction: Perform water testing in accordance with ATCP 76.18(3), everyday of the week when the pool is in operation.

      Code ATCP 76.18(3)

  4. May 30, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken: there are 3 pumps and 2 sp

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken: Luke closed the pool, then Corrected on site

      14c - CHLORINE TOO HIGH

      The chlorine residual exceeded 10 ppm. Free chlorine reading indicated 13.2 ppm.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for alkalinity and cyanuric acid are not in compliance with ATCP 76.18(1). Alkalinty and cyanuric acid testing not tracked on log sheet.

      Correction: Perform water testing in accordance with ATCP 76.18(1). Check alkalinity 2x/week and cyanuric acid 1x/week and record results on log sheet.

      Code ATCP 76.18(1)

    • Not serious Other

      34e - VGBA COVERS

      Documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date, however, 3 of the equalizer covers are in need of replacement (expired 2023).

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up or if they are broken.

      Code ATCP 76.11(2)(b)

  5. Jul 8, 2022 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      16b - CYANURIC ACID - Not Corrected

      The cyanuric acid concentration is 80ppm

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS - Not Corrected

      The water testing frequency for cyanuric acid and combined chlorine are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test cyanuric acid 1/week and combined chlorine 2/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED - Not Corrected

      Emergency phone is audible but cuts in and out when connected making it difficult to hear and understand emergency responder on the line.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  6. Jul 7, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      14c - CHLORINE TOO HIGH

      The chlorine residual exceeds 10 ppm.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range.

      Code ATCP 76.14(4)(f)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 80ppm

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for cyanuric acid and combined chlorine are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test cyanuric acid 1/week and combined chlorine 2/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Emergency phone is audible but cuts in and out when connected making it difficult to hear and understand emergency responder on the line.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      39e - WATER ATTRACTION - FENCE GAPS

      Gaps in the barrier at the base of the fence are 4-inches or larger.

      Correction: Modify the barrier so all gaps in the barrier are less than 4-inches.

      Code ATCP 76.36(1)(h)

  7. Jun 9, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 3, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  9. May 31, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 8, 2017 Re-Inspection · No Reinspection Required

    No violations cited.

  11. Jun 1, 2017 Routine Inspection · Reinspection Required

    No violations cited.

  12. Jul 7, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jul 31, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Jul 30, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  15. Aug 23, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.