Hawks Landing Pool And Tennis Club
66 HAWKS LANDING CIR, Verona, WI 53593 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 66647-68727
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 2 | 20 | 0 |
| 2024 | 1 | 5 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 14, 2025 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Operator has contacted a s
14e - WATER POTENTIAL ORP (Pf) - Not Corrected
The water potential was 535 mV at the time of the inspection. (Operator already tests pH and free chlorine more than twice/day.)
Correction: Recalibrate the oxidation potential controller to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: Email staffing plan to san
24a - LIFEGUARD - STAFFING PLAN (Ppf) - Not Corrected
The lifeguard staffing plan is missing diagram for swim team and is short one guard for open swim maximum patron load.
Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.
Code ATCP 76.22(1)
-
Not serious
Action taken:
27h - SIGNAGE - SLIDE RULES - Not Corrected
Posted slide rules are not in one inch tall letters are some rules are missing.
Correction: Provide an approved sign: POOL SLIDES AND WATERSLIDES. For the plunge section of a pool, the pool use rules signage required under sub. (1) shall also be conspicuously posted at the entrance to the slide tower in at least one inch lettering for all letters: 1. Do not use the slide while under the influence of alcohol or drugs. 2. Follow the instructions of the attendant. 3. Leave the plunge area i
Code ATCP 76.29(2)
-
Not serious
Action taken:
29d - DECK MAINTENANCE AND CLEANING (Pf) - Not Corrected
Some portions of the pool deck, particularly by the diving boards, are broken and in disrepair.
Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken: Operator has contacted a s
-
Jul 7, 2025 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
11a - CHEMICAL - LABELING (Pf)E
Large chlorine tanks is not labeled.
Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number, if applicable.
Code ATCP 76.12(1)
-
Not serious
Action taken: Operator moved acid and ch
11b - CHEMICAL - STORAGE (P)(Pf)
Containers of chlorine and acid are stored close together in entrance area to pump room. Chemical storage room door is not marked to indicate authorized personnel only and a list of emergency numbers was not present in the room.
Correction: Store chemicals in accordance with ATCP 76.12(2). Move acid and chlorine further apart. Lock doors to chemical storage areas and mark door to indicate entry is for authorized personnel only. Provide a list of emergency telephone numbers in the chemical storage room or have readily available.
Code ATCP 76.12(2)
-
Not serious
Action taken:
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator does not have documentation of interlock system monthly testing.
Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system testing. At least once/month, record date of test, test result, and name of tester.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP (Pf)
The water potential was 535 mV at the time of the inspection. (Operator already tests pH and free chlorine more than twice/day.)
Correction: Recalibrate the oxidation potential controller to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: Email plan to sanitarian o
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for combined chlorine, alkalinity, and cyanuric acid is not in compliance with ATCP 76.18(3). No tests recorded.
Correction: Perform water testing in accordance with ATCP 76.18(3). Test combined chlorine twice/week, and alkalinity and cyanuric acid once/week.
Code ATCP 76.18(3)
-
Not serious
Action taken: Email staffing plan to san
24a - LIFEGUARD - STAFFING PLAN (Ppf)
The lifeguard staffing plan is missing diagram for swim team and is short one guard for open swim maximum patron load.
Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.
Code ATCP 76.22(1)
-
Not serious
Action taken:
26f - PATRON LOAD - NOT POSTED (Pf)
The maximum patron load is not posted.
Correction: Post the maximum patron load conspicuously near each pool.
Code ATCP 76.29(1)(e)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken: Crook reassembled and moun
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)
Shepherd's crook is disassembled.
Correction: Mount shepherd's crook fully assembled at all times when pool is open in a conspicuous place that is readily accessible. Crook portion must be securely attached to pole.
Code ATCP 76.26(1)
-
Not serious
Action taken: Emergency number and addre
Corrected on site
26p - EMERGENCY NUMBERS AND ADDRESS (Pf)
The emergency numbers and the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near or attached to the designated emergency phone.
Code ATCP 76.26(2)(d)
-
Not serious
Action taken:
27h - SIGNAGE - SLIDE RULES
Posted slide rules are not in one inch tall letters are some rules are missing.
Correction: Provide an approved sign: POOL SLIDES AND WATERSLIDES. For the plunge section of a pool, the pool use rules signage required under sub. (1) shall also be conspicuously posted at the entrance to the slide tower in at least one inch lettering for all letters: 1. Do not use the slide while under the influence of alcohol or drugs. 2. Follow the instructions of the attendant. 3. Leave the plunge area i
Code ATCP 76.29(2)
-
Not serious
Action taken:
28c - FECAL/ VOMIT/ BLOOD RESPONSE DOCUMENTATION (Pf)
Documentation of fecal accident, vomit, and/ or blood incidents in the facility is missing.
Correction: Document each fecal, vomit and blood contamination incident pursuant to ATCP 76.31(2)(a)-(f) using current department form.
Code ATCP 76.31(2)
-
Not serious
Action taken:
28e -REPORTS AND RECORDS (Pf)
Operator is not using department provided report for logging of chemical testing.
Correction: The pool operator or responsible supervisor shall complete reports of the pool operation on forms provided by the department or its agent to include verification and documentation of all of the following: (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety
Code ATCP 76.32(1)
-
Not serious
Action taken:
29d - DECK MAINTENANCE AND CLEANING (Pf)
Some portions of the pool deck, particularly by the diving boards, are broken and in disrepair.
Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).
Code ATCP 76.33(1)(b)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room.
Correction: Install functioning carbon monoxide alarms as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken:
-
Jul 25, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 598mV at the time of the inspection. Water pH and chlorine is tested every two hours throughout the day.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: Discussed obtaining reagen
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine and cyanuric acid is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken: PIC immediately began upda
24a - LIFEGUARD - STAFFING PLAN
Lifeguard staffing plans are available and require updating. 1. Include attendant to monitor main entrance in lifeguard staffing plan (variance no longer required). 2. Include diagrams for each configuration of pool usage.
Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.
Code ATCP 76.22(1)(a)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
Eye wash is missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.
Code ATCP 76.27(1)
-
Not serious
Action taken: Repair effluent valve and/
31b - EQUIPMENT NOT MAINTAINED
Effluent gauge on filters is not reading. An additional psi reader is attached, unclear what psi the additionally installed valve is measuring.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
-
Jun 30, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 27, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 20, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 12, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 20, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 16, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 17, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 24, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 18, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.