Hub On Campus Madison
437 N Frances ST, Madison, WI 53703 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2015-00178
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 4 | 0 |
| 2024 | 1 | 1 | 0 |
| 2023 | 1 | 8 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 2 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
Inspections
-
Jan 28, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP (Pf)
The water potential was 594 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
29b - BASIN MAINTENANCE AND REPAIR
There are some cracked tiles and missing tiles in the pool basin.
Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.
Code ATCP 76.33(1)(a)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Flow sensor switches often getting stuck and not functioning properly. This equipment is not being maintained or repaired as necessary.
Correction: Properly locate, install, maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
32b - VENTILATION
The pool enclosure surfaces are showing signs of excessive condensation and air quality problems in indoor enclosures.
Correction: Repair the ventilation system to prevent condensation and air quality problems.
Code ATCP 76.33(4)(b)
-
Not serious
Action taken:
-
Dec 6, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 514 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
-
Jul 25, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
Corrected on site
04c - SKIMMER BASKET/WEIR
The skimmer weir doors are broken.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The facility's phone number on the sign by the emergency phone is inaccurate. The 911 operator stated the number is listed as 608-709-5957 and the sign states 608-709-5952.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26q - FIRST AID KIT - SUPPLIES MISSING
The first aid kit is missing most of the required supplies.
Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit. The first aid kit shall contain all of the following items: (a) Gauze pads ? 4'' x 4'' . (b) Gauze pads – 8'' x 10'' . (c) Adhesive bandages. (d) Triangular bandages. (e) Scissors. (f) Gauze roller bandage. (g) Tweezers. (h) Adhesive tape. (i) Eye wash. (j) Elastic bandage. (k) Disposable surgical gloves. (L) Resuscitation pocket
Code ATCP 76.27(1)
-
Not serious
Action taken:
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken:
29g - DRINKING FOUNTAIN
The drinking fountain is not functional. The sink faucet that is immediately adjacent to the drinking fountain is working using the hot water faucet handle; however, the cold water is turned off to this sink.
Correction: Repair the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
Air vent covers on the walls are rusted and peeling and are not being maintained and repaired as necessary.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA covers for main drain showing make /model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
Corrected on site
-
Jul 14, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Dec 4, 2019 Re-Inspection · No Reinspection Required
No violations cited.
-
Sep 4, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 11, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 16, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 17, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 16, 2015 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.