RecordWell Data

Paragon Place At Bear Claw Way

9603 Paragon ST, Middleton, WI 53562 · Dane County

14cited violations
0serious tier
8inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2018-00204
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026130
2025150
2024120
2022140
2021100
2019200
2018100

Inspections

  1. Jul 9, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill containment to prevent accidental mixing of extra containers of chlorine and acid.

      Correction: Store chemicals in accordance with ATCP 76.12(2). Provide overspill pallet containment or other approved means to prevent accidental mixing of chlorine and acid.

      Code ATCP 76.12(2)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' is not posted with 4 inch high letters in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken: staff repaired self-closin Corrected on site

      34a - GATES NOT MAINTAINED (P)

      The gate or door to the pool enclosure is not being maintained and checked for proper operation. Self-closing mechanism in disrepair.

      Correction: Repair and maintain the gate or door. Gate must be self-closing, latching, and lockable.

      Code ATCP 76.34(2)

  2. Jul 15, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Ron will provide overspill

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals are improperly stored in accordance with ATCP 76.12(2).

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for cyanuric acid is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record reading for cyanuric acid 1x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      Chlorine chemical feed line has observable crystallization from leak.

      Correction: Properly locate, install, maintain and repair equipment. Repair/replace chlorine feed line to eliminate any leakage.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Jun 10, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is between 50-60ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Jul 29, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket for the skimmers is not located on site .

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      26p - FIRST AID KIT - AVAILABLE

      A first aid kit is not available in the pool area.

      Correction: Provide a first aid kit in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

  5. Jun 29, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jul 2, 2019 Re-Inspection · No Reinspection Required

    No violations cited.

  7. Jul 1, 2019 Routine Inspection · Reinspection Required

    No violations cited.

  8. May 24, 2018 Pre-Inspection · No Reinspection Required

    No violations cited.