RecordWell Data

Paragon Place At Bear Claw Way

225 Lakota WAY, Middleton, WI 53562 · Dane County

16cited violations
0serious tier
4inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2023-00250
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026140
2025140
2024140
2023140

Inspections

  1. Jul 9, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      05b - WATER LEVEL (Pf)

      The pool water level is not adequate for continuous effective surface skimming. Too low.

      Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions.

      Code ATCP 76.11(2)(a) and ATCP 76.19(3)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals are improperly stored in accordance with ATCP 76.12(2). Ripped open bag of sodium bicarbonate observed on the floor in the pump room.

      Correction: Store chemicals in accordance with ATCP 76.12(2). Provide overspill containment to prevent acid from mixing with chlorine. Provide large container to store sodium bicarbonate.

      Code ATCP 76.12(2)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' is not posted with 4 inch high letters in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken: gate alignment and latchin Corrected on site

      34a - GATES NOT MAINTAINED (P)

      The gate or door to the pool enclosure is not being maintained and checked for proper operation. Electronic fob works, but door post was not aligned for proper operation. Pool patrons had propped the door to gain entry due to improper operation of latching mechanism.

      Correction: Repair and maintain the gate or door. Gate must be self-closing, latching, and lockable.

      Code ATCP 76.34(2)

  2. Jul 15, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for cyanuric acid is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record cyanuric acid readings 1/x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      Chlorine feeder line has observable crystallization from leakage.

      Correction: Properly locate, install, maintain and repair equipment. Repair/replace chlorine feeder line to eliminate any leakage.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarm as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Jun 10, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken: water level adjusted to mi

      05b - WATER LEVEL

      The pool water level is not adequate for continuous effective surface skimming. Too low.

      Correction: Adjust the water level until the skimming of the water surface is adequate.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken: for now, the street addres

      26o - EMERGENCY NUMBERS AND ADDRESS

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency and non-emergency numbers and facility's street address on signage near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious Action taken: pool will remain voluntari Corrected on site

      34a - GATES NOT MAINTAINED

      The gate to the pool enclosure is not being maintained. Electronic key fobs not programmed. Residents may be reaching over gate to activate escape bar mechanism to open gate. Note: the gate is self-closing, self-latching, and lockable (with chain/lock).

      Correction: Repair and maintain the gate's electronic key fobs. Voluntarily close pool until key fobs are reprogrammed. NOTE: If at any point the pool entrance gate no longer self-closes, self-latches, and is not lockable, then orders will be required to mandatorily close the pool at that time.

      Code ATCP 76.34(2)

    • Not serious Action taken: sign posted Corrected on site

      34d - POOL CLOSED SIGN

      There is no sign on the premises that indicates that the pool is closed.

      Correction: Provide a sign that communicates to the public that the pool is closed.

      Code ATCP 76.34(5)

  4. May 24, 2023 Pre-Inspection · Reinspection Required
    • Not serious Action taken:

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26o - EMERGENCY NUMBERS AND ADDRESS

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious 1. Do not enter the pool if you have a c

      27e - SIGNAGE - POOL RULES

      The pool rules are missing.

      Correction: Provide a sign in compliance with ATCP 76.29(1)(b).

      Code ATCP 76.29(1)(b)

    • Not serious Action taken: Pool operator adjusted the Corrected on site

      34c - DOOR/GATE

      The gate to the pool enclosure is not self-latching, and is not lockable.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.