Paragon Place At Bear Claw Way
225 Lakota WAY, Middleton, WI 53562 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2023-00250
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 4 | 0 |
| 2025 | 1 | 4 | 0 |
| 2024 | 1 | 4 | 0 |
| 2023 | 1 | 4 | 0 |
Inspections
-
Jul 9, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
05b - WATER LEVEL (Pf)
The pool water level is not adequate for continuous effective surface skimming. Too low.
Correction: Adjust the water level until the skimming of the water surface is adequate. Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions.
Code ATCP 76.11(2)(a) and ATCP 76.19(3)
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2). Ripped open bag of sodium bicarbonate observed on the floor in the pump room.
Correction: Store chemicals in accordance with ATCP 76.12(2). Provide overspill containment to prevent acid from mixing with chlorine. Provide large container to store sodium bicarbonate.
Code ATCP 76.12(2)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING (Pf)
'NO DIVING' is not posted with 4 inch high letters in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken: gate alignment and latchin
Corrected on site
34a - GATES NOT MAINTAINED (P)
The gate or door to the pool enclosure is not being maintained and checked for proper operation. Electronic fob works, but door post was not aligned for proper operation. Pool patrons had propped the door to gain entry due to improper operation of latching mechanism.
Correction: Repair and maintain the gate or door. Gate must be self-closing, latching, and lockable.
Code ATCP 76.34(2)
-
Not serious
Action taken:
-
Jul 15, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
20c - WATER TESTING - POOLS (Pf)
The water testing frequency for cyanuric acid is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record cyanuric acid readings 1/x/week.
Code ATCP 76.18(1)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Chlorine feeder line has observable crystallization from leakage.
Correction: Properly locate, install, maintain and repair equipment. Repair/replace chlorine feeder line to eliminate any leakage.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.
Correction: Install functioning carbon monoxide alarm as applicable.
Code ATCP 76.33(4)(d)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Jun 10, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: water level adjusted to mi
05b - WATER LEVEL
The pool water level is not adequate for continuous effective surface skimming. Too low.
Correction: Adjust the water level until the skimming of the water surface is adequate.
Code ATCP 76.11(2)(a)
-
Not serious
Action taken: for now, the street addres
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and/or the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency and non-emergency numbers and facility's street address on signage near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken: pool will remain voluntari
Corrected on site
34a - GATES NOT MAINTAINED
The gate to the pool enclosure is not being maintained. Electronic key fobs not programmed. Residents may be reaching over gate to activate escape bar mechanism to open gate. Note: the gate is self-closing, self-latching, and lockable (with chain/lock).
Correction: Repair and maintain the gate's electronic key fobs. Voluntarily close pool until key fobs are reprogrammed. NOTE: If at any point the pool entrance gate no longer self-closes, self-latches, and is not lockable, then orders will be required to mandatorily close the pool at that time.
Code ATCP 76.34(2)
-
Not serious
Action taken: sign posted
Corrected on site
34d - POOL CLOSED SIGN
There is no sign on the premises that indicates that the pool is closed.
Correction: Provide a sign that communicates to the public that the pool is closed.
Code ATCP 76.34(5)
-
Not serious
Action taken: water level adjusted to mi
-
May 24, 2023 Pre-Inspection · Reinspection Required
-
Not serious
Action taken:
26m - TELEPHONE - NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and/or the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
1. Do not enter the pool if you have a c
27e - SIGNAGE - POOL RULES
The pool rules are missing.
Correction: Provide a sign in compliance with ATCP 76.29(1)(b).
Code ATCP 76.29(1)(b)
-
Not serious
Action taken: Pool operator adjusted the
Corrected on site
34c - DOOR/GATE
The gate to the pool enclosure is not self-latching, and is not lockable.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Action taken:
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.