Princeton Club

2920 HARD ROCK RD, Fitchburg, WI 53719 · Dane County

17cited violations
0serious tier
6inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2018-00019
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20242110
2022260
2019100
2018100

Inspections

  1. Oct 16, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO

      The swimming pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(a)

    • Not serious Action taken: Discussed increasing deck

      29d - DECK DISINFECTION

      The pool areas are not being cleaned and sanitized regularly. PIC informed deck cleaning is occurring on a monthly to 6 week schedule but is vacuumed more frequently.

      Correction: Clean and sanitize the deck and appurtenances according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

    • Not serious Other

      41a - MISCELLANEOUS

      DSPS plan review documentation is not available for the upgraded pump installed last April. The new pump has more horsepower than the pump that was removed. The former pump is still present onsite.

      Correction: An operator shall submit pool modification plans to the Wisconsin department of safety and professional services pursuant to ch. SPS 390. Documentation shall be made available to the department or its agent upon request as required under sub. (1).

      Code ATCP 76.04(2)

  2. Mar 26, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Discuss contacting pool co

      05a - SKIMMER/MAIN DRAIN RATIO

      The skimmer to main drain flow ratio is not set correctly. PIC informed both valves have been intentionally set wide open to prevent air in pump.

      Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket for the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for alkalinity is not documented and therefore not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken: Sanitarian provided templa

      24a - LIFEGUARD - STAFFING PLAN

      The lifeguard staffing plan is out dated.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken: Class ended, discussed req

      25g - LIFEGUARD - NOT CONSPICUOUS

      A lifeguard is not wearing clothing that is conspicuously marked 'Lifeguard' or 'Guard.'

      Correction: Ensure that lifeguards are properly identified at all times when on duty.

      Code ATCP 76.22(3)(a)

    • Not serious Action taken: Class ended, discussed req

      25h - LIFEGUARD - NO EQUIPMENT

      A lifeguard is not wearing a rescue tube and/or a whistle.

      Correction: Ensure that lifeguards are wearing the proper gear at all times when on duty.

      Code ATCP 76.22(3)(a)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      Several items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Other

      34e - VGBA COVERS

      PIC informed VGBA main drain and equalizers have been recently replaced. Documentation is not available on site for newly installed VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  3. Jun 22, 2022 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO - Not Corrected

      The swimming pool has a maximum turnover rate of greater than 6 hours. Currently, the turnover rate of the swimming pool is 11.4 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(a)

  4. Jun 13, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO

      The swimming pool has a maximum turnover rate of greater than 6 hours. Currently, the turnover rate of the swimming pool is 11.4 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(a)

    • Not serious Action taken:

      17a - CHLORINE GENERATORS - SECONDARY SYSTEM

      The liquid chlorine secondary disinfection system is no longer automatic. The operator is manually turning on and off the liquid chlorine disinfection system.

      Correction: Repair system so the liquid chlorine secondary disinfection system functions automatically. Close the swimming pool until the secondary disinfection system is repaired.

      Code ATCP 76.15(1)

    • Not serious Action taken:

      20a - TEST KIT NOT APPROVED

      The test kit used by the facility has expired reagents for the total alkalinity test.

      Correction: Replace the test kit.

      Code ATCP 76.17(1)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for pH, free chlorine, and total alkalinity is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Any of the following conditions or situa

      28a - CLOSING CRITERIA

      The pool was not closed under the following condition: operator tested free Chlorine level at 16.0 ppm this morning around 6 a.m. and secondary disinfection system is not automatic.

      Correction: Ensure that the closing criteria are adhered to under the listed below.

      Code ATCP 76.30

  5. Aug 9, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jan 19, 2018 Pre-Inspection · No Reinspection Required

    No violations cited.