Seminole Pool & Tennis Club
5948 SCHUMANN DR, Fitchburg, WI 53711 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2010-00234
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 6 | 0 |
| 2025 | 1 | 7 | 0 |
| 2024 | 1 | 4 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Aug 17, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Complete checklist and mai
13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)
Operator cannot demostrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).
Correction: Operator must be able to demostrate knowledge and provide documentation of interlock system.
Code ATCP 76.13(1)(c)
-
Not serious
Action taken: Head guard completed form
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan or is not following combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency is not in compliance with ATCP 76.18(3). Both basins share disinfection system and some days only the main pool is tested.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken:
26f - PATRON LOAD - NOT POSTED (Pf)
The maximum patron load is not posted in the wading pool area.
Correction: Post the maximum patron load conspicuously near each pool.
Code ATCP 76.29(1)(e)
-
Not serious
Action taken:
26r - FIRST AID KIT - SUPPLIES MISSING (Pf)
Gauze roller bandage and adhesive tape are missing from the first aid kit.
Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.
Code ATCP 76.27(1)(b)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
In pump room effluent pressure gauge is non functional.
Correction: Properly locate, intall, maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken: Complete checklist and mai
-
Jun 17, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
16d - COMBINED CHLORINE (Pf)
The operator does not have a combined chlorine plan or is not following combined chlorine plan.
Correction: Provide a plan with all components required under ATCP 76.14(5)(e)
Code ATCP 76.14(5)(e)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency is not in compliance with ATCP 76.18(3). Both basins share a disinfectant system, only the main pool basin is tested.
Correction: Perform water testing in accordance with ATCP 76.18(3).
Code ATCP 76.18(3)
-
Not serious
Action taken: PIC rewrote patron load on
Corrected on site
26c - PATRON LOAD - WADING POOLS (Pf)
The posted maximum patron load is not posted, the number written has faded.
Correction: Calculate and post the maximum patron load in compliance with ATCP 76.25(2).
Code ATCP 76.25(2)(c)
-
Not serious
Action taken:
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
Biohazard kit is missing several items.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Action taken:
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Equipment is not maintained and repaired as necessary. 1. Flow meter bobber is stuck on the bottom of reader. 2. Effluent gauge for sand filters is non operational.
Correction: Properly locate, install, maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Jun 10, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
24b - LIFEGUARD - SIGNAGE MISSING
A pool basin in the facility does not have a 'No Lifeguard on Duty' sign.
Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.
Code ATCP 76.22(1)(c); ATCP 76.23(2)
-
Not serious
Action taken: PIC added patron load to s
Corrected on site
26f - PATRON LOAD - NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken: PIC moved signage to post
27e - SIGNAGE - POOL RULES
The pool rules signage is resting on deck in the main pool enclosure area.
Correction: Provide a sign in compliance with ATCP 76.29(1)(b) posted in a conspicuous place.
Code ATCP 76.29(1)(a)
-
Not serious
Other
34e - VGBA COVERS
1. A screw is missing on the main drain. 2. No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 14, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 22, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 11, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 9, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 27, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 8, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 10, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 10, 2013 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 18, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.